Negative intracuff pressure inside the deflated cuff of an endotracheal tube

被引:0
|
作者
Kumar, Sanjeev [1 ]
Agarwal, Rishabh [1 ,2 ]
机构
[1] Maharaja Agrasen Med Coll, Dept Anaesthesiol, Hisar, Haryana, India
[2] Maharaja Agrasen Med Coll, Dept Anaesthesiol, Hisar 125001, Haryana, India
关键词
D O I
10.4103/ija.ija_952_22
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
引用
收藏
页码:315 / 317
页数:3
相关论文
共 50 条
  • [41] Elevated endotracheal tube cuff pressure in the pediatric emergency department
    Ferenczy, Edward D.
    Stoner, Michael J.
    Spencer, Sandra P.
    Gee, Samantha W.
    Scherzer, Daniel J.
    Tobias, Joseph D.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2018, 113 : 289 - 291
  • [42] Accuracy of an inexpensive, disposable endotracheal tube cuff pressure manometer
    Frakes, Michael A.
    Pylant, Rogers T.
    Williams, Anthony
    CRITICAL CARE MEDICINE, 2007, 35 (12) : A229 - A229
  • [43] ENDOTRACHEAL-TUBE CUFF PRESSURE - IS A SYRINGE A RELIEF VALVE
    GUYTON, DC
    BEARD, HR
    ANESTHESIOLOGY, 1994, 81 (3A) : A496 - A496
  • [44] Changes in endotracheal tube intracuff pressure and air leak pressure over time in anesthetized Beagle dogs
    Shin, Chi Won
    Son, Won-gyun
    Jang, Min
    Kim, Hyunseok
    Han, Hyungjoo
    Cha, Jeesoo
    Lee, Inhyung
    VETERINARY ANAESTHESIA AND ANALGESIA, 2018, 45 (06) : 737 - 744
  • [45] Residual volume in the cuff of the endotracheal tube when the pilot balloon is torn off instead of deflated using a syringe
    Kamata, Mineto
    Hakim, Mumin
    Tobias, Joseph D.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2016, 86 : 15 - 18
  • [46] Endotracheal tube cuff pressure changes during manual cuff pressure control manoeuvres: A call for continuous cuff pressure regulation?
    Maertens, Bert
    Blot, Stijn
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2019, 63 (05) : 700 - 701
  • [47] INTRACUFF PRESSURES IN ENDOTRACHEAL AND TRACHEOSTOMY TUBES - RELATED CUFF PHYSICAL CHARACTERISTICS
    BERNHARD, WN
    YOST, L
    JOYNES, D
    COTHALIS, S
    TURNDORF, H
    CHEST, 1985, 87 (06) : 720 - 725
  • [48] AN ENDOTRACHEAL TUBE WITH A CELLOPHANE CUFF
    JACKSON, RR
    ROKOWSKI, WJ
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1967, 199 (10): : 756 - &
  • [49] ENDOTRACHEAL TUBE CUFF DISPLACEMENT
    COPPEN, JE
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1967, 200 (05): : 420 - &
  • [50] Comment on a published article: Too much of anything is bad: An unusual case of a stuck endotracheal tube with deflated cuff
    Kumar, Akhil
    Dutta, Amitabh
    Sood, Jayashree
    SAUDI JOURNAL OF ANAESTHESIA, 2020, 14 (01) : 130 - 130