Development of a newly compact double-focusing mass spectrometer

被引:1
|
作者
Yang, Zhe [1 ]
Li, Detian [1 ]
Ren, Zhengyi [1 ]
Geng, Jian [2 ]
Sun, Jian [3 ]
Wang, Xuezhi [3 ]
Li, Gang [2 ]
Cheng, Yongjun [1 ]
Zhang, Hong [1 ]
Guo, Meiru [1 ]
机构
[1] Lanzhou Inst Phys, Sci & Technol Vacuum Technol & Phys Lab, Lanzhou 730000, Peoples R China
[2] Northeastern Univ, Sch Mech Engn & Automat, Shenyang 110819, Peoples R China
[3] Jinan Univ, Guangzhou 510632, Peoples R China
基金
中国国家自然科学基金;
关键词
Compact; Double-focusing; Mass resolution; Sensitivity; Minimum detectable partial pressure; ION; PERFORMANCE; DESIGN;
D O I
10.1016/j.vacuum.2023.111815
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In recent years, mass spectrometers play an important role in space missions. Based on this, we introduced a newly developed compact double-focusing mass spectrometer. The MS mainly consists of three parts, that is, electron ionization source, electrostatic and magnetic analyzer, focal plane detector. The ionization source employed two identical tungsten-rhenium alloy filaments to avoid failure of the number one filament. Two analyzers connect in reverse to reduce the size and the focal plane detector detects signals simultaneously. This instrument has a 90 degrees magnetic analyzer with asymmetric structure, which has a magnetic flux density of 0.25T. Results show that the H2 peak width Delta M at 50% peak height (FWMH) is 0.080amu which is less than 0.1amu. That is to say, the developed DFMS has a good resolution capability. Besides, the instrument's mass range is 2-69amu, the physical unit weight is 4.9 kg, the dimension is 247mm x 129mm x 128 mm and the power consumption is less than 30 W.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] DOUBLE-FOCUSING DIODE
    TAKAGI, K
    APPLIED PHYSICS LETTERS, 1978, 33 (05) : 376 - 378
  • [42] SECTOR-TYPE DOUBLE-FOCUSING BETA-RAY SPECTROMETER
    SAKAI, M
    IKEGAMI, H
    YAMAZAKI, T
    NUCLEAR INSTRUMENTS & METHODS, 1960, 9 (02): : 154 - 164
  • [43] ADVANTAGES OF A 2ND ELECTRIC SECTOR ON A DOUBLE-FOCUSING MASS-SPECTROMETER OF REVERSED CONFIGURATION
    GUILHAUS, M
    BOYD, RK
    BRENTON, AG
    BEYNON, JH
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1985, 67 (02): : 209 - 227
  • [44] OBSERVATION OF INTACT (HEME-BOUND) MYOGLOBIN BY ELECTROSPRAY IONIZATION ON A DOUBLE-FOCUSING MASS-SPECTROMETER
    LOO, JA
    GIORDANI, AB
    MUENSTER, H
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (03) : 186 - 189
  • [45] A NOVEL, DOUBLE-FOCUSING SPECTROMETER FOR TRANSLATIONAL-ENERGY-LOSS SPECTROSCOPY
    BEYNON, JH
    BRENTON, AG
    TAYLOR, LCE
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1985, 64 (02): : 237 - 244
  • [46] A novel double-focusing time-of-flight mass spectrometer for absolute recoil ion cross sections measurements
    Sigaud, L.
    de Jesus, V. L. B.
    Ferreira, Natalia
    Montenegro, E. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (08):
  • [47] Ion optical evaluation of a miniature double-focusing mass spectrograph
    Nishiguchi, Masaru
    Ishihara, Morio
    Katakuse, Itsuo
    Toyoda, Michisato
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2008, 14 (01) : 7 - 15
  • [48] DOUBLE-FOCUSING MASS SPECTROMETERS OF SHORT PATH-LENGTH
    MATSUDA, H
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 93 (03): : 315 - 321
  • [49] ANALYSIS OF MONITOR-READING ERRORS ON A DOUBLE-FOCUSING, SPARK-ION-SOURCE MASS-SPECTROMETER
    GALBURG, VA
    GLAVIN, GG
    ZELENIN, AE
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1974, 29 (07): : 1223 - 1225
  • [50] A double focusing mass spectrometer for geochronology
    De Laeter, JR