A simple aptamer/gold nanoparticle aggregation-based colorimetric assay for oxidized low-density lipoprotein determination

被引:12
|
作者
Khongwichit, Soemwit [1 ,2 ]
Swangphon, Piyawut [1 ]
Nanakorn, Natthaphon [1 ]
Nualla-ong, Aekkaraj [2 ]
Choowongkomon, Kiattawee [3 ]
Lieberzeit, Peter A. [4 ]
Chunta, Suticha [1 ]
机构
[1] Prince Songkla Univ, Fac Med Technol, Hat Yai 90110, Thailand
[2] Prince Songkla Univ, Fac Sci, Div Biol Sci, Hat Yai 90110, Thailand
[3] Kasetsart Univ, KU Inst Adv Studies Ctr Adv Studies Nanotechnol Ch, Food & Agr Ind, Bangkok 10900, Thailand
[4] Univ Vienna, Fac Chem, Dept Phys Chem, A-1090 Vienna, Austria
关键词
Oxidized low-density lipoprotein; Aptamer; Gold nanoparticle; Colorimetric assay; LIPID-PEROXIDATION; OXIDATIVE STRESS; LABEL-FREE; IN-VIVO; ATHEROSCLEROSIS; LDL;
D O I
10.1016/j.talanta.2022.124199
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Oxidized low-density lipoprotein (oxLDL) is the leading cause of atherosclerosis and cardiovascular diseases. Here, we created a simple colorimetric assay for sensitive and specific determination of oxLDL using a selective aptamer coupled with salt-induced gold nanoparticle (AuNP) aggregation. The aptamer was chosen by Sys-tematic Evolution of Ligands by Exponential Enrichment to obtain a novel selective sequence towards oxLDL (as 5 '-CCATCACGGGGCAGGCGGACAAGGGGTAAGGGCCACATCA-3 '). Mixing a 5 mu M aptamer solution with an aliquot of a sample containing oxLDL followed by adding AuNP solution (OD = 1) and 80 mmol L-1 NaCl ach-ieved rapid results within 19 min: linear response to oxLDL from 0.002 to 0.5 mu mol L-1 with high selectivity, a recovery accuracy of 100-111% at the 95% confidence interval, and within-run and between-run precision of 1-6% and 1-5% coefficient variations, respectively. Artificial serum diluted at least 1:8 with distilled water, analyzed by the aptamer-based colorimetric assay, showed excellent correlation with conventional thiobarbituric acid reactive substances (TBARS) (R2 = 0.9792) as a rapid colorimetric method without the need for sample preparation other than dilution.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Simple and sensitive aptamer-based colorimetric sensing of protein using unmodified gold nanoparticle probes
    Wei, Hui
    Li, Bingling
    Li, Jing
    Wang, Erkang
    Dong, Shaojun
    CHEMICAL COMMUNICATIONS, 2007, (36) : 3735 - 3737
  • [32] Using Simple-Structured Split Aptamer for Gold Nanoparticle-based Colorimetric Detection of Estradiol
    Chia-Chen Chang
    Chung-Yu Yeh
    Analytical Sciences, 2021, 37 : 479 - 483
  • [33] Gold Nanoparticle-based Colorimetric Assay for Determination of Lead(II) in Aqueous Media
    Li Xiao-kun
    Wang Zhen-xin
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2010, 26 (02) : 194 - 197
  • [34] A simple and sensitive colorimetric pH meter based on DNA conformational switch and gold nanoparticle aggregation
    Chen, Cuie
    Song, Guangtao
    Ren, Jinsong
    Qu, Xiaogang
    CHEMICAL COMMUNICATIONS, 2008, (46) : 6149 - 6151
  • [35] Exercise shifts the platelet aggregation modulatory role from native to mildly oxidized low-density lipoprotein
    Hsu, HC
    Lee, YT
    Chen, MF
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (05): : 933 - 939
  • [36] Colorimetric method for determination of bisphenol A based on aptamer-mediated aggregation of positively charged gold nanoparticles
    Jingyue Xu
    Ying Li
    Jiaxin Bie
    Wei Jiang
    Jiajia Guo
    Yeli Luo
    Fei Shen
    Chunyan Sun
    Microchimica Acta, 2015, 182 : 2131 - 2138
  • [37] Colorimetric method for determination of bisphenol A based on aptamer-mediated aggregation of positively charged gold nanoparticles
    Xu, Jingyue
    Li, Ying
    Bie, Jiaxin
    Jiang, Wei
    Guo, Jiajia
    Luo, Yeli
    Shen, Fei
    Sun, Chunyan
    MICROCHIMICA ACTA, 2015, 182 (13-14) : 2131 - 2138
  • [38] CdS nanocrystal-based electrochemiluminescence biosensor for the detection of low-density lipoprotein by increasing sensitivity with gold nanoparticle amplification
    Jie, Guifen
    Liu, Bo
    Pan, Hongcheng
    Zhu, Jun-Jie
    Chen, Hong-Yuan
    ANALYTICAL CHEMISTRY, 2007, 79 (15) : 5574 - 5581
  • [39] Simple and fast colorimetric detection of lipopolysaccharide based on aptamer and SYBR Green I mediated aggregation of gold nanoparticles
    Jiang, Jiajun
    Huang, Bingna
    Li, Ningjun
    An, Changcheng
    Sun, Changjiao
    Shen, Yue
    Gooneratne, Ravi
    Cui, Haixin
    Zhan, Shenshan
    Wang, Yan
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2022, 223 : 231 - 239
  • [40] A Synthetic Peptide-Based Assay System for Detecting Binding between CD36 and an Oxidized Low-Density Lipoprotein
    Tsuzuki, Satoshi
    Takai, Marie
    Matsuno, Yukari
    Kozai, Yuki
    Fujioka, Maiko
    Kamei, Kozue
    Inagaki, Hitomi
    Eguchi, Ai
    Matsumura, Shigenobu
    Inoue, Kazuo
    Fushiki, Tohru
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2013, 77 (01) : 132 - 137