Assessment of intrafractional motion of the cervix-uterus by MR-guided radiotherapy system

被引:0
|
作者
Nagao, Ayaka [1 ]
Okamoto, Hiroyuki [2 ,5 ]
Nakayama, Hiroki [2 ]
Chiba, Takahito [2 ]
Fujiyama, Daisuke [3 ]
Kuwahara, Junichi [3 ]
Sakasai, Tatsuya [3 ]
Kashihara, Tairo [1 ]
Kaneda, Tomoya [1 ]
Inaba, Koji [1 ]
Okuma, Kae [1 ]
Murakami, Naoya [1 ,4 ]
Igaki, Hiroshi [1 ]
机构
[1] Tokyo Ctr Hosp, Natl Canc Ctr Hosp, Dept Radiat Oncol, 5-1-1 Tsukiji,Chuo Ku, Tokyo 1040045, Japan
[2] Natl Canc Ctr, Radiat Safety & Qual Assurance Div, 5-1-1 Tsukiji,Chuo Ku, Tokyo 1040045, Japan
[3] Natl Canc Ctr, Dept Radiol Technol, 5-1-1 Tsukiji,Chuo ku, Tokyo 1040045, Japan
[4] Juntendo Univ, Dept Radiat Oncol, Grad Sch Med, 3-1-3 Hongo,Bunkyo ku, Tokyo 1138431, Japan
[5] Natl Canc Ctr, Common Dept, Radiat Safety & Qual Assurance Div, 51-1 Tsukiji,Chuo ku, Tokyo 1040045, Japan
关键词
uterus movement; MR-guided radiation therapy; radiotherapy; cervix; intrafraction; DOSIMETRIC PARAMETERS; HEMATOLOGIC TOXICITY; ORGAN MOTION; CANCER; CARCINOMA; IMRT;
D O I
10.1093/jrr/rrad072
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The uterus is known as one of the moving organs. We evaluated the movement of the uterus during irradiation and the effects of changes in the surrounding organs using a magnetic resonance (MR)-guided radiotherapy system. Seven patients with cervical cancer underwent pre-and posttreatment MR imaging to assess changes in the positioning of the uterus and cervix as well as the alterations in bladder and rectal volume. The study revealed that the movements of the uterus were greater than that of the cervix and showed a tendency to correlate with the bladder rather than the rectum. We also examined whether intrafractional motion could lead to insufficient dose coverage of the clinical target volume (CTV), specifically focusing on the D98% of the CTV in the uterine body and cervix. The impact of intrafractional motion on the D98% varied among patients, with one out of the seven patients experiencing an average dosimetric change of -2.6 Gy in the uterus, although larger planning target volume margins of 1.5 cm were applied, therefore, indicating the need for individualized optimal margins in each case. Online adaptive radiotherapy offers the advantage of modifying the treatment plan when irradiating moving organs, such as the uterus. However, it should be noted that this approach may result in longer overall treatment times compared with the traditional methods. Therefore, we must carefully consider the influence of intrafractional organ motions when opting for such a treatment.
引用
收藏
页码:967 / 972
页数:6
相关论文
共 50 条
  • [41] Online MR-guided radiotherapy - Adaptation by size or function
    Bhide, S.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S422 - S422
  • [42] Practical guidelines of online MR-guided adaptive radiotherapy
    Okamoto, Hiroyuki
    Igaki, Hiroshi
    Chiba, Takahito
    Shibuya, Keiko
    Sakasai, Tatsuya
    Jingu, Keiichi
    Inaba, Koji
    Kuroda, Kagayaki
    Aoki, Shigeki
    Tatsumi, Daisaku
    Nakamura, Mitsuhiro
    Kadoya, Noriyuki
    Furuyama, Yoshinobu
    Kumazaki, Yu
    Tohyama, Naoki
    Tsuneda, Masato
    Nishioka, Shie
    Itami, Jun
    Onishi, Hiroshi
    Shigematsu, Naoyuki
    Uno, Takashi
    JOURNAL OF RADIATION RESEARCH, 2022, 63 (05) : 730 - 740
  • [43] Online rotation correction for MR-guided prostate radiotherapy
    Van den Wollenberg, W.
    Carbaat, C.
    De Ruiter, P.
    Remeijer, P.
    Janssen, T.
    Sonke, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1096 - S1097
  • [44] MR-Guided Radiotherapy: Magnetic Field Dose Effects
    Raaijmakers, A. J. E.
    Raaymakers, B. W.
    Lagendijk, J. J. W.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [45] Medical physics challenges in clinical MR-guided radiotherapy
    Kurz, Christopher
    Buizza, Giulia
    Landry, Guillaume
    Kamp, Florian
    Rabe, Moritz
    Paganelli, Chiara
    Baroni, Guido
    Reiner, Michael
    Keall, Paul J.
    van den Berg, Cornelis A. T.
    Riboldi, Marco
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [46] The impact of rectal spacers in MR-guided adaptive radiotherapy
    Batumalai, Vikneswary
    Crawford, David
    Picton, Maddison
    Tran, Charles
    Jelen, Urszula
    Carr, Madeline
    Jameson, Michael
    de Leon, Jeremy
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2024, 49
  • [47] MR-Guided Adaptive Radiotherapy in Localized Prostate Cancer
    Allegra, Andrea Gaetano
    Nicosia, Luca
    Rigo, Michele
    Bianchi, Nicola
    Borgese, Riccardo Filippo
    De Simone, Antonio
    Giaj-Levra, Niccolo
    Gurrera, Davide
    Naccarato, Stefania
    Pastorello, Edoardo
    Ricchetti, Francesco
    Sicignano, Gianluisa
    Ruggieri, Ruggero
    Alongi, Filippo
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2025, 24
  • [48] Transcranial MR-Guided Histotripsy System
    Lu, Ning
    Hall, Timothy L.
    Choi, Dave
    Gupta, Dinank
    Daou, Badih, Jr.
    Sukovich, Jonathan R.
    Fox, Adam
    Gerhardson, Tyler, I
    Pandey, Aditya S.
    Noll, Douglas C.
    Xu, Zhen
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (09) : 2917 - 2929
  • [49] Simultaneous motion monitoring and truth-in-delivery analysis imaging framework for MR-guided radiotherapy
    Mickevicius, Nikolai J.
    Chen, Xinfeng
    Boyd, Zachary
    Lee, Hannah J.
    Ibbott, Geoffrey S.
    Paulson, Eric S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (23):
  • [50] Accuracy of DIR-based intra-fraction motion management in MR-guided radiotherapy
    Palacios, M. A.
    Gerganov, G.
    Cobussen, P.
    Tetar, S. U.
    Finazzi, T.
    Slotman, B. J.
    Senan, S.
    Haasbeek, C. J.
    Kawrakow, I.