Sparse2Noise: Low-dose synchrotron X-ray tomography without high-quality reference data

被引:1
|
作者
Duan, Xiaoman [1 ]
Ding, Xiao Fan [1 ]
Li, Naitao [1 ]
Wu, Fang-Xiang [1 ,2 ,3 ]
Chen, Xiongbiao [1 ,3 ]
Zhu, Ning [1 ,4 ,5 ]
机构
[1] Univ Saskatchewan, Coll Engn, Div Biomed Engn, Saskatoon, SK S7N 5A9, Canada
[2] Univ Saskatchewan, Dept Comp Sci, Saskatoon, SK S7N 5A9, Canada
[3] Univ Saskatchewan, Coll Engn, Dept Mech Engn, Saskatoon, SK S7N 5A9, Canada
[4] Canadian Light Source, Saskatoon, SK S7N 2V3, Canada
[5] Univ Saskatchewan, Coll Engn, Dept Chem & Biol Engn, Saskatoon, SK S7N 5A9, Canada
基金
加拿大创新基金会; 加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
Synchrotron radiation; Computed tomography; Radiation dose; 3D reconstruction; Convolutional neural network; MICRO-CT; COMPUTED-TOMOGRAPHY; IMAGE; NETWORK; PHASE; RECONSTRUCTION; OPTIMIZATION;
D O I
10.1016/j.compbiomed.2023.107473
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Synchrotron radiation computed tomography (SR-CT) holds promise for high-resolution in vivo imaging. Notably, the reconstruction of SR-CT images necessitates a large set of data to be captured with sufficient photons from multiple angles, resulting in high radiation dose received by the object. Reducing the number of projections and/or photon flux is a straightforward means to lessen the radiation dose, however, compromises data completeness, thus introducing noises and artifacts. Deep learning (DL)-based supervised methods effectively denoise and remove artifacts, but they heavily depend on high-quality paired data acquired at high doses. Although algorithms exist for training without high-quality references, they struggle to effectively eliminate persistent artifacts present in real-world data.Methods: This work presents a novel low-dose imaging strategy namely Sparse2Noise, which combines the reconstruction data from paired sparse-view CT scan (normal-flux) and full-view CT scan (low-flux) using a convolutional neural network (CNN). Sparse2Noise does not require high-quality reconstructed data as references and allows for fresh training on data with very small size. Sparse2Noise was evaluated by both simulated and experimental data.Results: Sparse2Noise effectively reduces noise and ring artifacts while maintaining high image quality, outperforming state-of-the-art image denoising methods at same dose levels. Furthermore, Sparse2Noise produces impressive high image quality for ex vivo rat hindlimb imaging with the acceptable low radiation dose (i.e., 0.5 Gy with the isotropic voxel size of 26 mu m).Conclusions: This work represents a significant advance towards in vivo SR-CT imaging. It is noteworthy that Sparse2Noise can also be used for denoising in conventional CT and/or phase-contrast CT.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] A statistical iteration approach with energy minimization to sinogram noise reduction for low-dose X-ray CT
    Liu, Yi
    Gui, Zhi-guo
    OPTIK, 2012, 123 (23): : 2174 - 2178
  • [42] Noise reduction for low-dose X-ray CT based on fuzzy logical in stationary wavelet domain
    Liu, Yi
    Gui, Zhiguo
    Zhang, Quan
    OPTIK, 2013, 124 (18): : 3348 - 3352
  • [43] Low-dose x-ray phase-contrast and absorption CT using equally sloped tomography
    Fahimian, Benjamin P.
    Mao, Yu
    Cloetens, Peter
    Miao, Jianwei
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (18): : 5383 - 5400
  • [44] Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction
    Huang, Hsuan-Ming
    Hsiao, Ing-Tsung
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [45] Bayesian sinogram smoothing with an anisotropic diffusion weighted prior for low-dose X-ray computed tomography
    Zhang, Quan
    Gui, Zhiguo
    Chen, Yang
    Li, Yuanfin
    Luo, Limin
    OPTIK, 2013, 124 (17): : 2811 - 2816
  • [46] Limited parameter denoising for low-dose X-ray computed tomography using deep reinforcement learning
    Patwari, Mayank
    Gutjahr, Ralf
    Raupach, Rainer
    Maier, Andreas
    MEDICAL PHYSICS, 2022, 49 (07) : 4540 - 4553
  • [47] Poisson-Gaussian Noise Analysis and Estimation for Low-Dose X-ray Images in the NSCT Domain
    Lee, Sangyoon
    Lee, Min Seok
    Kang, Moon Gi
    SENSORS, 2018, 18 (04)
  • [48] Low-dose hypersensitivity in nucleus-irradiated V79 cells studied with synchrotron X-ray microbeam
    Maeda, Munetoshi
    Usami, Noriko
    Kobayashi, Katsumi
    JOURNAL OF RADIATION RESEARCH, 2008, 49 (02) : 171 - 180
  • [49] Low-dose abdominal computed tomography for detection of urinary stone disease - Impact of additional spectral shaping of the X-ray beam on image quality and dose parameters
    Dewes, Patricia
    Frellesen, Claudia
    Scholtz, Jan-Erik
    Fischer, Sebastian
    Vogl, Thomas J.
    Bauer, Ralf W.
    Schulz, Boris
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (06) : 1058 - 1062
  • [50] High-resolution, low-dose phase contrast X-ray tomography for 3D diagnosis of human breast cancers
    Zhao, Yunzhe
    Brun, Emmanuel
    Coan, Paola
    Huang, Zhifeng
    Sztrokay, Aniko
    Diemoz, Paul Claude
    Liebhardt, Susanne
    Mittone, Alberto
    Gasilov, Sergei
    Miao, Jianwei
    Bravin, Alberto
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2012, 109 (45) : 18290 - 18294