Bump deposition techniques for hybrid X-ray detectors

被引:3
|
作者
Schneider, Andreas [1 ]
Ghorbanian, Navid [1 ]
Osborn, Jack [1 ]
Cross, Simon P. [1 ]
Lipp, John D. [1 ]
French, Marcus J. [1 ]
机构
[1] Rutherford Appleton Lab RAL, Sci & Technol Facil Council STFC, Harwell Campus, Didcot OX11 0QX, England
来源
JOURNAL OF INSTRUMENTATION | 2023年 / 18卷 / 06期
关键词
Gamma detectors (scintillators; CZT; HPGe; HgI etc); Manufacturing; X-ray detectors;
D O I
10.1088/1748-0221/18/06/C06009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Flip-chip bonding is a common method for joining application-specific integrated circuits (ASIC) to pixel sensors in order to build hybrid radiation detectors for X-rays and gamma-rays. STFC-RAL is using two methods for the interconnects between ASIC and sensor pixels. These are either indium bumps which are deposited on ASIC and sensor prior to bonding or alternatively electrically conductive adhesive dots are printed on the sensor pixel array and flip-chip bonded to gold studs attached to each pixel of the ASIC. Conventionally the indium deposition is carried out on wafer-scale using a photolithographic lift-off process. Sensor and ASIC with indium bumps are singulated from wafers afterwards. Some sensor material (e.g. CdZnTe) which is required for high-energy and high-flux X-ray detectors at X-ray Free Electron Lasers (XFEL) or in other scientific experiments is only available as individual die instead of wafers. The stencil printing of conductive epoxy dots onto those sensor dies together with gold ball studding of ASICs is a suitable method for those dies. However, due to the size of printed epoxy dots this method has a limited pixel pitch and is currently only used for sensors with 250 gm-pitch or for larger pitch. A novel method for indium deposition was developed for such dies. A shadow mask with small apertures is optically aligned to the pixel array and mechanically clamped to the sensor die. After indium evaporation onto this assembly and after removal of the mask, indium bumps as small as 50 gm with a height of & SIM; 5 gm are deposit onto the pixel array of the sensor. The same is done for a matching ASIC. A comparison of these two methods indicates that indium bumps created by the shadow mask technique are approx. half the size of the epoxy dots and comparable with gold studs. Using this method, at present a pitch of 100 gm for those indium bumps can be achieved and development for further improvement towards smaller pitch is carried out currently. This novel indium deposition method is compared with the conventional wafer-scale indium lift-off method and the epoxy/gold stud flip-chip bonding in terms of interconnect quality, bond yield, and suitability for hybrid radiation detectors.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Techniques and detectors for polarimetry in X-ray astronomy
    Soffitta, P
    Baldini, L
    Bellazzini, R
    Brez, A
    Costa, E
    Di Persio, G
    Latronico, L
    Omodei, N
    Pacciani, L
    Spandre, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 510 (1-2): : 170 - 175
  • [2] Study of Surface Passivation and Contact Deposition Techniques in CdZnTe X-Ray and Gamma-Ray Detectors
    Jones, Dominique E.
    Egarievwe, Stephen U.
    Hossain, Anwar
    Okwechime, Ifechukwude O.
    Drabo, Mebougna L.
    Hall, JaQueeta
    Adams, Aaron L.
    Babalola, Stephen O.
    Camarda, Giuseppe S.
    Bolotnikov, Aleksey E.
    Chan, Wing
    James, Ralph B.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4124 - 4127
  • [3] Hybrid CMOS X-ray detectors: The next generation for focused X-ray telescopes
    Falcone, A. D.
    Burrows, D. N.
    Bai, Y.
    Farris, M.
    Cook, R.
    Bongiorno, S.
    UV, X-RAY, AND GAMMA-RAY SPACE INSTRUMENTATION FOR ASTRONOMY XV, 2007, 6686
  • [4] Advances in array detectors for X-ray diffraction techniques
    Hanley, QS
    Denton, MB
    JOURNAL OF SYNCHROTRON RADIATION, 2005, 12 : 618 - 625
  • [5] Hybrid Pixel Detectors for gamma/X-ray imaging
    Hatzistratis, D.
    Theodoratos, G.
    Zografos, V.
    Kazas, I.
    Loukas, D.
    Lambropoulos, C. P.
    INTERNATIONAL CONFERENCE ON BIO-MEDICAL INSTRUMENTATION AND RELATED ENGINEERING AND PHYSICAL SCIENCES (BIOMEP 2015), 2015, 637
  • [6] Small pixel hybrid CMOS X-ray detectors
    Hull, Samuel V.
    Falcone, Abraham D.
    Burrows, David N.
    Wages, Mitchell
    McQuaide, Maria
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY VIII, 2018, 10709
  • [7] Hybrid CMOS detectors for the Lynx x-ray surveyor high definition x-ray imager
    Hull, Samuel, V
    Falcone, Abraham D.
    Bray, Evan
    Wages, Mitchell
    McQuaide, Maria
    Burrows, David N.
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2019, 5 (02)
  • [8] Response of chemical vapor deposition diamond detectors to X-ray
    Zhang, ML
    Xia, YB
    Wang, LJ
    Shen, HJ
    SOLID STATE COMMUNICATIONS, 2004, 130 (06) : 425 - 428
  • [9] Techniques in X-ray astronomy2. Imaging detectors
    Kulinder Pal Singh
    Resonance, 2005, 10 (7) : 8 - 20
  • [10] Event recognition techniques in CCD X-ray detectors for astronomy
    Lumb, David H.
    Holland, Andrew D.