摘要
Improved focal plane array detector systems are described which can provide improved readout speeds, random addressing and even be employed to simultaneously measure position, intensity and energy. This latter capability promises to rekindle interests in Laue techniques. Simulations of three varieties of foil mask spectrometer in both on- and off-axis configurations indicate that systems of stacked silicon detectors can provide energy measurements within 1% of the true value based on the use of single 'foils' and similar to 10000 photons. An eight-detector hybrid design can provide energy coverage from 4 to 60 keV. Energy resolution can be improved by increased integration time or higher flux experiments. An off-axis spectrometer design in which the angle between the incident beam and the detector system is 45 degrees results in a shift in the optimum energy response of the spectrometer system. In the case of a 200 mu m-thick silicon absorber, the energy optimum shifts from 8.7 keV to 10.3 keV as the angle of incidence goes from 0 to 45 degrees. These new designs make better use of incident photons, lower the impact of source flicker through simultaneous rather than sequential collection of intensities, and improve the energy range relative to previously reported systems.
引用
收藏
页码:618 / 625
页数:8
相关论文
共 50 条
  • [1] X-ray diffraction techniques
    Zaumseil, P
    EFFECT OF DISORDER AND DEFECTS IN ION-IMPLANTED SEMICONDUCTORS : ELECTRICAL AND PHYSICOCHEMICAL CHARACTERIZATION, 1997, 45 : 261 - 282
  • [2] A diffraction effect in X-ray area detectors
    Gollwitzer, C. (christian.gollwitzer@ptb.de), 1600, International Union of Crystallography, 5 Abbey Road, Chester, CH1 2HU, United Kingdom (47):
  • [3] A diffraction effect in X-ray area detectors
    Gollwitzer, Christian
    Krumrey, Michael
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2014, 47 : 378 - 383
  • [4] Advances in silicon carbide X-ray detectors
    Bertuccio, Giuseppe
    Caccia, Stefano
    Puglisi, Donatella
    Macera, Daniele
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 193 - 196
  • [5] Research advances on X-ray pixel detectors
    Li, Zhenjie
    Zhang, Jie
    Li, Mujin
    Cui, Shanshan
    Wei, Wei
    Kexue Tongbao/Chinese Science Bulletin, 2022, 67 (32): : 3808 - 3822
  • [6] Research advances on X-ray pixel detectors
    Li, Zhenjie
    Zhang, Jie
    Li, Mujin
    Cui, Shanshan
    Wei, Wei
    CHINESE SCIENCE BULLETIN-CHINESE, 2022, 67 (32): : 3808 - 3822
  • [7] Techniques and detectors for polarimetry in X-ray astronomy
    Soffitta, P
    Baldini, L
    Bellazzini, R
    Brez, A
    Costa, E
    Di Persio, G
    Latronico, L
    Omodei, N
    Pacciani, L
    Spandre, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 510 (1-2): : 170 - 175
  • [8] ADVANCES IN SYNCHROTRON X-RAY POLYCRYSTALLINE DIFFRACTION
    PARRISH, W
    AUSTRALIAN JOURNAL OF PHYSICS, 1988, 41 (02): : 101 - 112
  • [9] STORAGE PHOSPHOR X-RAY DIFFRACTION DETECTORS.
    Whiting, Bruce R.
    Owen, James F.
    Rubin, Byron H.
    Nuclear instruments and methods in physics research, 1987, A266 (1-3): : 628 - 635
  • [10] Recent advances in X-ray photoconductors for direct conversion X-ray image detectors
    Kasap, S. O.
    Kabir, M. Zahangir
    Rowlands, J. A.
    CURRENT APPLIED PHYSICS, 2006, 6 (03) : 288 - 292