Enhancing Trace Metal Extraction from Wastewater: Magnetic Activated Carbon as a High-Performance Sorbent for Inductively Coupled Plasma Optical Emission Spectrometry Analysis

被引:4
|
作者
Abellan-Martin, Sergio J. [1 ]
Villalgordo-Hernandez, David [2 ]
Aguirre, Miguel Angel [1 ]
Ramos-Fernandez, Enrique V. [2 ]
Narciso, Javier [2 ,3 ]
Canals, Antonio [1 ]
机构
[1] Univ Alicante, Univ Inst Mat, Fac Sci, Dept Analyt Chem & Food Sci, POB 99, Alicante 03080, Spain
[2] Univ Inst Mat, Univ Alicante, Fac Sci, Dept Inorgan Chem, POB 99, Alicante 03080, Spain
[3] Inst Invest Sanitaria & Biomed Alicante ISABIAL, Alicante 03010, Spain
关键词
magnetic dispersive solid-phase extraction (MDSPE); magnetic activated carbon; trace metal analysis; multivariate optimization; wastewater samples; inductively coupled plasma optical emission spectrometry (ICP OES); SOLID-PHASE EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; LIQUID-LIQUID MICROEXTRACTION; ENVIRONMENTAL-SAMPLES PRIOR; CLOUD POINT EXTRACTION; BIOLOGICAL SAMPLES; HEAVY-METALS; CAPILLARY MICROEXTRACTION; MASS SPECTROMETRY; AQUEOUS-SOLUTIONS;
D O I
10.3390/separations10110563
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new fast, sensitive, and environmentally friendly analytical method has been developed for the simultaneous determination of Ba, Be, Cd, Cr, Cu, Fe, Hg, Mn, Ni, Pb, and Zn in wastewater samples using inductively coupled plasma optical emission spectroscopy (ICP OES). A preconcentration step using a magnetic dispersive solid-phase extraction (MDSPE) technique with a new magnetic sorbent was performed. The new sorbent material was a carbon containing magnetic cobalt and nitrogen groups. This material was synthetized using controlled pyrolysis of a zeolitic imidazolate framework (i.e., ZIF-67). In order to optimize the experimental parameters that affect the MDSPE procedure, a multivariate optimization strategy, using Plackett-Burman and circumscribed central composite designs (CCD), was used. The method has been evaluated employing optimized experimental conditions (i.e., sample weight, 10 g; sample pH, 7.6; amount of sorbent, 10 mg; dispersive agent, vortex; complexing agent concentration, 0.5%; ionic concentration, 0%; eluent, HCl; eluent concentration, 0.5 M; eluent volume, 300 mu L; elution time, 3 min and extraction time, 3 min) using external calibration. Limits of detection (LODs) in a range from 0.073 to 1.3 mu g L-1 were obtained, and the repeatability was evaluated at two different levels, resulting in relative standard deviations below 8% for both levels (n = 5). An increase in the sensitivity was observed due to the high enrichment factors (i.e., 3.2 to 13) obtained compared with direct ICP OES analysis. The method was also validated through carrying out recovery studies that employed a real wastewater sample and through the analysis of a certified reference material (ERM (R)-CA713). The recovery values obtained with the real wastewater were between 94 and 108% and between 90 and 109% for the analysis of ERM (R)-CA713, showing negligible matrix effects.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Determination of trace impurities in tantalum powder and its compounds by inductively coupled plasma optical emission spectrometry using solvent extraction
    Anil, G.
    Reddy, M. R. P.
    Prakash, T. L.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 61 (07) : 641 - 643
  • [22] Determination of trace impurities in tantalum powder and its compounds by inductively coupled plasma optical emission spectrometry using solvent extraction
    Anil, G.
    Reddy, M.R.P.
    Prakash, T.L.
    Journal of Analytical Chemistry, 2006, 61 (07): : 641 - 643
  • [23] Determination of trace impurities in tantalum powder and its compounds by inductively coupled plasma optical emission spectrometry using solvent extraction
    G. Anil
    M. R. P. Reddy
    T. L. Prakash
    Journal of Analytical Chemistry, 2006, 61 : 641 - 643
  • [24] High-Throughput Soil Analysis Using Inductively Coupled Plasma-Optical Emission Spectrometry
    Hannan, James
    SPECTROSCOPY, 2012, 27 (11) : 32 - +
  • [25] Electrospray as interface in the coupling micro high-performance liquid chromatography to inductively coupled plasma atomic emission spectrometry
    Univ of Amsterdam, Amsterdam, Netherlands
    J Anal At Spectrom, 9 (1065-1068):
  • [26] Electrospray as interface in the coupling of micro high-performance liquid chromatography to inductively coupled plasma atomic emission spectrometry
    Elgersma, JW
    Kraak, JC
    Poppe, H
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) : 1065 - 1068
  • [27] On-line preconcentration/determination of copper in parenteral solutions using activated carbon by inductively coupled plasma optical emission spectrometry
    Takara, EA
    Pasini-Cabello, SD
    Cerutti, S
    Gásquez, JA
    Martinez, LD
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) : 735 - 739
  • [28] Determination of trace impurities in high purity metal tin by ultrasonic nebulization inductively coupled plasma-atomic emission spectrometry
    Zhou, SP
    Zhu, GH
    Yin, JY
    Hu, QF
    Wang, GC
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (01) : 66 - 68
  • [29] Arsenic Species Analysis at Trace Level by High Performance Liquid Chromatography with Inductively Coupled Plasma Mass Spectrometry
    Hou, Hongfang
    Cui, Wanjing
    Xu, Qing
    Tao, Zhanhui
    Guo, Yafei
    Deng, Tianlong
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 2019
  • [30] Analysis of Radium-226 in High Salinity Wastewater from Unconventional Gas Extraction by Inductively Coupled Plasma-Mass Spectrometry
    Zhang, Tieyuan
    Bain, Daniel
    Hammack, Richard
    Vidic, Radisav D.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (05) : 2969 - 2976