Simultaneous subcutaneous implantable cardioverter-defibrillator and leadless pacemaker implantation for patients at high risk of infection: a retrospective case series report

被引:2
|
作者
Calvagna, Giuseppe M. [1 ]
Valsecchi, Sergio [2 ]
机构
[1] ARNAS Garibaldi Ctr, Dept Cardiol, Catania, Italy
[2] Boston Sci, Milan, Italy
关键词
Implantable defibrillator; Subcutaneous; Leadless pacemaker; Extraction; Infection; ELECTRONIC DEVICE INFECTION; EUROPEAN-SOCIETY; COMPLICATIONS; ASSOCIATION; MORTALITY; ELIGIBILITY; EXTRACTION; MANAGEMENT; THERAPY; HRS;
D O I
10.1007/s10840-023-01684-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe subcutaneous implantable cardioverter defibrillator (S-ICD) and leadless pacemaker (LP) are alternative options for patients at high risk of infection requiring ICD and pacing therapy. In this analysis, we described the simultaneous implantation of S-ICD and LP in patients with high infectious risk.MethodsThe study cohort comprised patients referred to our institution for ICD implantation due to high-risk factors of infection.ResultsBetween 2018 and 2022, 13 patients were referred, including 11 with infected ICD and 2 for first ICD implantation in the presence of high-risk factors. In cases of infected ICD, successful extraction was performed using a mechanical dilatation technique. Reimplantation was delayed until resolution of infection with antibiotic therapy. The devices were implanted during a single procedure, with S-ICD implantation following LP placement for verification of sensing adequacy through surface ECG screening. Suitable vectors for sensing during inhibited and ventricular pacing were identified in all patients. Defibrillation testing was effective, and no issues with double counting or undersensing were observed. The postoperative period was uneventful, and during a median follow-up of 35 months, no complications or infections were reported. The median ventricular pacing percentage was 5%, and a single inappropriate shock episode due to myopotential interference was reported and resolved by reprogramming the sensing vector.ConclusionSimultaneous implantation of S-ICD and LP is feasible and safe in patients at high risk of infection requiring both ICD and pacing therapy. This combined approach provides an effective solution for these patients.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] CONSISTENT SUBCUTANEOUS PREPECTORAL IMPLANTATION OF A NEW IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    STANTON, MS
    HAYES, DL
    MUNGER, TM
    TRUSTY, JM
    ESPINOSA, RE
    SHEN, WK
    OSBORN, MJ
    PACKER, DL
    HAMMILL, SC
    MAYO CLINIC PROCEEDINGS, 1994, 69 (04) : 309 - 314
  • [22] Implantation of the subcutaneous implantable cardioverter-defibrillator with truncal plane blocks
    Miller, Marc A.
    Bhatt, Himani V.
    Weiner, Menachem
    Brouwer, Tom F.
    Mittnacht, Alexander J.
    Shariat, Ali
    Jeng, Christina L.
    Eden, Caroline
    Lin, Hung-Mo
    Salter, Benjamin
    Dukkipati, Srinivas R.
    Reddy, Vivek Y.
    HEART RHYTHM, 2018, 15 (07) : 1108 - 1111
  • [23] Syncope in implantable cardioverter-defibrillator pacemaker dependent patients
    Cavaco, D
    Adragäo, P
    Aguiar, C
    Neves, J
    Abecasis, M
    Morgado, F
    Bonhorst, D
    Seabra-Gomes, R
    EUROPEAN HEART JOURNAL, 2002, 23 : 665 - 665
  • [24] First case of subcutaneous implantable cardioverter-defibrillator extrusion
    Santarpia, Giuseppe
    Polimeni, Alberto
    De Rosa, Salvatore
    Sabatino, Jolanda
    Curcio, Antonio
    Indolfi, Ciro
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 192 : 19 - 20
  • [25] Subcutaneous implantable cardioverter-defibrillator implantation for ventricular fibrillation caused by coronary artery spasm: a case report
    Ito, Naruhiko
    Kurabayashi, Manabu
    Okishige, Kaoru
    Hirao, Kenzo
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2018, 2 (03)
  • [26] Antithrombotic therapy and the risk of pocket hematoma after subcutaneous implantable cardioverter-defibrillator implantation
    Pepplinkhuizen, S.
    Kors, N.
    de Veld, J. A.
    Dijkshoorn, L. A.
    Bijsterveld, N. R.
    de Weger, A.
    Smeding, L.
    Wilde, A. A. M.
    Nordkamp, L. R. A. Olde
    Knops, R. E.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2025,
  • [27] Antithrombotic therapy and the risk of pocket hematoma after subcutaneous implantable cardioverter-defibrillator implantation
    Pepplinkhuizen, S.
    Kors, N.
    De Veld, J. A.
    Dijkshoorn, L. A.
    Bijsterveld, N. R.
    De Weger, A.
    Smeding, L.
    Wilde, A. A. M.
    Nordkamp, L. R. A. Olde
    Knops, R. E.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [28] Novel Communicating Leadless Pacemaker and Subcutaneous Implantable Cardioverter-Defibrillator System Provide Stable Long-Term Performance
    Breeman, Karel T.
    Swackhamer, Bryan J.
    Brisben, Amy
    Quast, Anne-Floor B.
    Shuros, Allan
    Soltis, Brian
    Koop, Brendan
    Burke, Martin C.
    Wilde, Arthur A.
    Tjong, Fleur V.
    Knops, Reinoud E.
    CIRCULATION RESEARCH, 2021, 129 (12) : E243 - E244
  • [29] Inappropriate Shocks With Subcutaneous Implantable Cardioverter-Defibrillator in a Young Patient: A Case Report
    Khan, Zahid
    Sethumadhavan, Dinesh
    Rayner, Tom
    Kyaw, Sithu
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [30] CASE REPORT: SUBCUTANEOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR SYSTEM S-ICD
    Scipione, P.
    Luzi, M.
    Bedendi, N.
    Andraghetti, A.
    Capucci, A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S150 - S150