The development of a clearance level radioactive waste measurement system using an array of NaI(Tl) detectors

被引:1
|
作者
Li, C. G. [1 ]
Gao, F. [1 ]
Sun, H. M. [1 ]
Zhao, D. S. [1 ]
Su, M. [1 ]
Bai, H. Y. [1 ]
Xiong, Z. H. [1 ]
Mo, Z. H. [1 ]
机构
[1] China Acad Engn Phys, Inst Mat, Mianyang 621908, Peoples R China
基金
中国国家自然科学基金;
关键词
Clearance level radioactive waste; NaI(Tl) detector array; Detection efficiency; Minimum detectable activity; EFFICIENCY;
D O I
10.1016/j.nima.2023.168748
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In order to meet the needs of rapid classification and measurement of the radioactive waste, a clearance level radioactive waste measurement system has been successfully developed and applied, achieving the goal of waste minimization. The measurement system consisted of 34 NaI(Tl) detectors taking into account the detector layout, detection efficiency and shielding chamber (to reduce the background of the environment). The NaI(Tl) detector array was built by a geometric condition of spatially symmetric to measure gamma rays. The shielding chamber composed of 2 mm copper and 10 mm lead is used as an passive shielding, and the radioactive waste is placed inside the shielding chamber, which suppress the gamma rays from the decay of 40K, 208Tl and other nuclides in the environment. A method to determine the counting of energy interval for the gamma rays is proposed to obtain the radioactivity of the radioactive waste package. The performance testing results of the measurement system show that the energy resolution and efficiency for 661.7 keV (137Cs) are 7.84% and 69.49% respectively, and the minimum detectable activity of 137Cs is 24.52 Bq. All these indicate that the indices of the clearance level radioactive waste measurement system have reached the international recommended level.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] A NaI(Tl)-based radioactive noble-gas monitoring system used for radiation monitoring
    Li, HuiBin
    Lei, WeiGuo
    Feng, TianCheng
    Huang, DingWei
    Tian, ZiNing
    APPLIED RADIATION AND ISOTOPES, 2020, 163
  • [32] Development and application of a radioactivity characterization system for low-level radioactive waste
    Espartero, AG
    Piña, G
    Suárez, JA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 790 - 794
  • [33] HASL GE(LI)-NAI(TL) LOW-LEVEL COUNTING SYSTEM
    LATNER, N
    SANDERSON, CG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, NS19 (01) : 141 - +
  • [34] Uncertainty derived from elemental analysis and its effect on the separation of radioactive waste into low-level radioactive waste and waste for clearance
    Kinoshita, Norikazu
    Noto, Takuma
    Kosako, Kazuaki
    Asada, Motoyuki
    Torii, Kazuyuki
    Tada, Akane
    Urabe, Kohei
    Ohtsuki, Tsutomu
    Sekimoto, Shun
    PROGRESS IN NUCLEAR ENERGY, 2021, 131
  • [35] Spectrum-dose conversion operator of NaI(Tl) and CsI(Tl) scintillation detectors for air dose rate measurement in contaminated environments
    Tsuda, Shuichi
    Saito, Kimiaki
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2017, 166 : 419 - 426
  • [36] Temperature Peak-Drift Correction Method for NaI(Tl) Detectors Using the Background Peak
    Wen, Songlin
    Zhou, Rong
    SENSORS, 2024, 24 (08)
  • [37] Clearance of very low level radioactive waste in Spanish nuclear power plants
    Alvarez-Mir, F
    REWAS'99 GLOBAL SYMPOSIUM ON RECYCLING, WASTE TREATMENT AND CLEAN TECHNOLOGY VOLUME I-III, 1999, : 851 - 856
  • [38] NaI(Tl) Detector Efficiency Computation Using Radioactive Parallelepiped Sources Based on Efficiency Transfer Principle
    Badawi, Mohamed S.
    Gouda, Mona M.
    El-Khatib, Ahmed M.
    Thabet, Abouzeid A.
    Salim, Ahmed A.
    Abbas, Mahmoud I.
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2015, 2015
  • [39] First results of a dedicated breast PET imager, BPET, using NaI(Tl) curve plate detectors
    Freifelder, R
    Cardi, C
    Grigoras, L
    Saffer, JR
    Karp, JS
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1241 - 1245
  • [40] Improvement ofin vivoneutron activation analysis of Mn using a 4π NaI(Tl) detector array
    Byun, S. H.
    Pejovic-Milic, A.
    Prestwich, W. V.
    Chettle, D. R.
    McNeill, F. E.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2006, 269 (03) : 615 - 618