Evaluation of automated techniques for extraction of circulating cell-free DNA for implementation in standardized high-throughput workflows

被引:5
|
作者
Lehle, Sarah [1 ]
Emons, Julius [1 ]
Hack, Carolin C. [1 ]
Heindl, Felix [1 ]
Hein, Alexander [1 ]
Preuss, Caroline [1 ]
Seitz, Katharina [1 ]
Zahn, Anna L. [1 ]
Beckmann, Matthias W. [1 ]
Fasching, Peter A. [1 ]
Ruebner, Matthias [1 ]
Huebner, Hanna [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Erlangen Univ Hosp, Comprehens Canc Ctr Erlangen EMN, Dept Gynecol & Obstet, Univ Str 21-23, D-91054 Erlangen, Germany
关键词
METASTATIC BREAST-CANCER; MITOCHONDRIAL-DNA; LIQUID BIOPSY; PLASMA DNA; QUANTITATIVE-ANALYSIS; TUMOR PROGRESSION; COPY NUMBER; INTEGRITY; MUTATIONS; BIOMARKER;
D O I
10.1038/s41598-022-27216-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Analysis of circulating cell-free DNA (ccfDNA) is a suitable tool for detecting somatic mutations for the purpose of making decisions on treatment, monitoring treatment response, and predicting survival. High-throughput techniques for ccfDNA extraction are essential to implementing ccfDNA testing in the clinical setting. We set out to compare two automated techniques with regard to hands-on time, ccfDNA output and integrity, and circulating mitochondrial DNA (mtDNA). CcfDNA was isolated using the EZ1&2 ccfDNA field test kit (EZ2 kit, QIAGEN) and the Maxwell RSC ccfDNA plasma kit (Maxwell kit, Promega). DNA was extracted from plasma of 30 breast cancer patients enrolled in the iMODE-B (#325_19B; 12.10.2020) study. Real-time PCR, fluorescence-based detection and automated electrophoresis were used to assess ccfDNA concentrations. The ccfDNA yield was significantly higher when extracted with the EZ2 kit. The EZ2 kit enabled the isolation of a higher proportion of short fragments and a lower proportion of long fragments, resulting in lower DNA integrity. Significantly lower mtDNA quantities were detected in the Maxwell eluate than in the EZ2 eluate. Thus, decisions on which extraction method to use should proceed on the basis of the required input for downstream applications, the anticipated fragment size and minimum hands-on time.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] High-throughput and affordable genome-wide methylation profiling of circulating cell-free DNA by methylated DNA sequencing (MeD-seq) of LpnPI digested fragments
    Teoman Deger
    Ruben G. Boers
    Vanja de Weerd
    Lindsay Angus
    Marjolijn M. J. van der Put
    Joachim B. Boers
    Z. Azmani
    Wilfred F. J. van IJcken
    Dirk J. Grünhagen
    Lisanne F. van Dessel
    Martijn P. J. K. Lolkema
    Cornelis Verhoef
    Stefan Sleijfer
    John W. M. Martens
    Joost Gribnau
    Saskia M. Wilting
    Clinical Epigenetics, 2021, 13
  • [42] High-throughput screening of biomolecules using cell-free gene expression systems
    Contreras-Llano, Luis E.
    Tan, Cheemeng
    SYNTHETIC BIOLOGY, 2018, 3 (01)
  • [43] Sensitivity assessment of workflows detecting rare circulating cell-free DNA targets: A study design proposal
    Voss, Thorsten
    Ullius, Andrea
    Schonborn, Maike
    Oelmuller, Uwe
    PLOS ONE, 2021, 16 (07):
  • [44] High levels of circulating cell-free DNA are a biomarker of active SLE
    Xu, Yalan
    Song, Yijun
    Chang, Jiazhen
    Zhou, Xiya
    Qi, Qingwei
    Tian, Xinping
    Li, Mengtao
    Zeng, Xiaofeng
    Xu, Mengnan
    Zhang, Wenjuan
    Cram, David S.
    Liu, Juntao
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2018, 48 (11)
  • [45] Automated Microfluidic Instrument for Label-Free and High-Throughput Cell Separation
    Zhang, Xinjie
    Zhu, Zhixian
    Xiang, Nan
    Long, Feifei
    Ni, Zhonghua
    ANALYTICAL CHEMISTRY, 2018, 90 (06) : 4212 - 4220
  • [46] Evaluation of High-Throughput PCR and Microarray-Based Assay in Conjunction with Automated DNA Extraction Instruments for Diagnosis of Sepsis
    Laakso, Sanna
    Kirveskari, Juha
    Tissari, Paivi
    Maki, Minna
    PLOS ONE, 2011, 6 (11):
  • [47] Comparison of Circulating Cell-Free DNA Extraction Methods for Downstream Analysis in Cancer Patients
    van der Leest, Paul
    Boonstra, Pieter A.
    ter Elst, Arja
    van Kempen, Leon C.
    Tibbesma, Marco
    Koopmans, Jill
    Miedema, Anneke
    Tamminga, Menno
    Groen, Harry J. M.
    Reyners, Anna K. L.
    Schuuring, Ed
    CANCERS, 2020, 12 (05)
  • [48] Evaluation of Sample Stability and Automated DNA Extraction for Fetal Sex Determination Using Cell-Free Fetal DNA in Maternal Plasma
    Ordonez, Elena
    Rueda, Laura
    Paz Canadas, M.
    Fuster, Carme
    Cirigliano, Vincenzo
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [49] Evaluation of Two Methods for Generating Circulating Cell-Free DNA Reference Materials
    Liu, L.
    Chou, D.
    Chuang, H.
    Crain, B.
    Du, T.
    Granger, G.
    Gua, Y.
    Han, Y.
    Jiang, T.
    Johansen, S.
    Sigrid, K.
    LoCoco, J.
    O'Brien, K.
    Purdy, A.
    Salmans, M.
    Vijayaraghavan, R.
    Wu, K.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2017, 19 (06): : 1045 - 1045
  • [50] A bilayer cell-free protein synthesis system for high-throughput screening of gene products
    Sawasaki, T
    Hasegawa, Y
    Tsuchimochi, M
    Kamura, N
    Ogasawara, T
    Kuroita, T
    Endo, Y
    FEBS LETTERS, 2002, 514 (01) : 102 - 105