摘要
Intra-canal fracture of rotary NiTi instruments occurs due to torsional stress, cyclic fatigue, or a combination of these two factors. Broken instruments are a serious obstacle to shaping, cleaning, and filling of the root canal and can adversely affect the outcome of endodontic therapy. The aim of this study was to examine the magnetic properties and ultrastructural changes of new, used, and fractured NiTi instruments using opto-magnetic imaging spectroscopy (OMIS). The study included three sets of different types of rotary instruments: MTwo (VDW, Munich, Germany), Pro Taper Universal (Dentsply Maillefer, Ballaigues, Switzerland), and BioRace (FKG DENTAIRE Swiss Dental Products, Le Cret-du-Locle Switzerland). Root canal shaping was performed on root canals with different curvatures, and after intra-canal fracture, in-struments of the same type (new, used, and fractured) were analyzed using OMIS at the Faculty of Mechanical Engineering, University of Belgrade. The obtained results showed a coincidence of peak localization for the used instruments that did not suffer a fracture, as well as for new, unused instruments of all examined groups. Additionally, there was a coincidence of peak intensities for new and fractured instruments in all groups. The specific treatment of electropolishing of the active surface of BioRace instruments caused a completely different electromagnetic response compared to conventional NiTi sets of tested instruments. New, unused BioRace instruments had the most pronounced pos-itive (5.6078 n.a.u. x1000) and negative (-8.5218 n.a.u. x1000) intensity values. The analysis of NiTi instruments using opto-magnetic imaging spectroscopy indicated changes in the magnetic properties after their instrumentation.
引用
收藏
页数:9
相关论文
共 29 条
  • [21] Finite element design optimisation by DOE technique of the torsional stress behaviour for NiTi rotary endodontic instruments
    Franco Maria Di Russo
    Annamaria Gisario
    Alessio Zanza
    Stefano Natali
    Giuseppe Ruta
    Luca Testarelli
    The International Journal of Advanced Manufacturing Technology, 2025, 136 (5) : 2377 - 2395
  • [22] Influence of an Innovative Anti-Corrosive Solution on Resistance of Endodontic NiTi Rotary Instruments: A Preliminary Study
    Saghiri, Mohammed Ali
    Asatourian, Armen
    Godoy, Franklin Garcia
    Sheibani, Nader
    EUROPEAN ENDODONTIC JOURNAL, 2018, 3 (01): : 55 - 60
  • [23] Role of the Flat-Designed Surface in Improving the Cyclic Fatigue Resistance of Endodontic NiTi Rotary Instruments
    Gambarini, Gianluca
    Miccoli, Gabriele
    Seracchiani, Marco
    Khrenova, Tatyana
    Donfrancesco, Orlando
    D'Angelo, Maurilio
    Galli, Massimo
    Di Nardo, Dario
    Testarelli, Luca
    MATERIALS, 2019, 12 (16)
  • [24] Predictive Value of Opto-magnetic Imaging Spectroscopy in Discriminating Oral Squamous Cell Carcinoma from Non-tumor Tissue in Surgical Margins
    Bogdan Lisul
    Drago Jelovac
    Milan Petrovic
    Zvezdana Tepavcevic
    Djuro Koruga
    Djurica Grga
    Journal of Medical and Biological Engineering, 2019, 39 : 874 - 884
  • [25] Predictive Value of Opto-magnetic Imaging Spectroscopy in Discriminating Oral Squamous Cell Carcinoma from Non-tumor Tissue in Surgical Margins
    Lisul, Bogdan
    Jelovac, Drago
    Petrovic, Milan
    Tepavcevic, Zvezdana
    Koruga, Djuro
    Grga, Djurica
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2019, 39 (06) : 874 - 884
  • [26] Design, Metallurgical Features, and Mechanical Behaviour of NiTi Endodontic Instruments from Five Different Heat-Treated Rotary Systems
    Martins, Jorge N. R.
    Silva, Emmanuel J. N. L.
    Marques, Duarte
    Pereira, Mario Rito
    Vieira, Victor T. L.
    Arantes-Oliveira, Sofia
    Martins, Rui F.
    Braz Fernandes, Francisco
    Versiani, Marco
    MATERIALS, 2022, 15 (03)
  • [27] Feasibility and resolution limits of opto-magnetic imaging of neural network activity in brain slices using color centers in diamond
    Karadas, Mursel
    Wojciechowski, Adam M.
    Huck, Alexander
    Dalby, Nils Ole
    Andersen, Ulrik Lund
    Thielscher, Axel
    SCIENTIFIC REPORTS, 2018, 8
  • [28] Feasibility and resolution limits of opto-magnetic imaging of neural network activity in brain slices using color centers in diamond
    Mürsel Karadas
    Adam M. Wojciechowski
    Alexander Huck
    Nils Ole Dalby
    Ulrik Lund Andersen
    Axel Thielscher
    Scientific Reports, 8
  • [29] Magnetic Resonance Imaging for Assessment of Endodontic Instruments' Precision during "L-Shaped" Model Root Canals Preparation
    Olek, Tomasz
    Weglarz, Wladyslaw P.
    Trzcionka, Agata
    Dziedzic, Arkadiusz
    Tanasiewicz, Marta
    APPLIED SCIENCES-BASEL, 2021, 11 (03): : 1 - 15