Opto-magnetic imaging spectroscopy in analyzing rotary NiTi endodontic instruments

被引:4
|
作者
Jovanovic-Medojevic, Milica [1 ]
Dragicevic, Aleksandra [2 ]
Milanovic, Ivana [1 ]
Matija, Lidija [2 ]
Zivkovic, Slavoljub [1 ]
机构
[1] Univ Belgrade, Sch Dent Med, Dept Restorat Dent & Endodont, Rankeova 4, Belgrade 11000, Serbia
[2] Univ Belgrade, Fac Mech Engn, Dept Biomed Engn, Kraljice Marije 16, Belgrade 11120, Serbia
关键词
NiTi instruments; Fractures of NiTi instruments; OMIS; CYCLIC FATIGUE; SEPARATION; DEFECTS; TISSUES; FILES;
D O I
10.1016/j.jmbbm.2023.105789
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intra-canal fracture of rotary NiTi instruments occurs due to torsional stress, cyclic fatigue, or a combination of these two factors. Broken instruments are a serious obstacle to shaping, cleaning, and filling of the root canal and can adversely affect the outcome of endodontic therapy. The aim of this study was to examine the magnetic properties and ultrastructural changes of new, used, and fractured NiTi instruments using opto-magnetic imaging spectroscopy (OMIS). The study included three sets of different types of rotary instruments: MTwo (VDW, Munich, Germany), Pro Taper Universal (Dentsply Maillefer, Ballaigues, Switzerland), and BioRace (FKG DENTAIRE Swiss Dental Products, Le Cret-du-Locle Switzerland). Root canal shaping was performed on root canals with different curvatures, and after intra-canal fracture, in-struments of the same type (new, used, and fractured) were analyzed using OMIS at the Faculty of Mechanical Engineering, University of Belgrade. The obtained results showed a coincidence of peak localization for the used instruments that did not suffer a fracture, as well as for new, unused instruments of all examined groups. Additionally, there was a coincidence of peak intensities for new and fractured instruments in all groups. The specific treatment of electropolishing of the active surface of BioRace instruments caused a completely different electromagnetic response compared to conventional NiTi sets of tested instruments. New, unused BioRace instruments had the most pronounced pos-itive (5.6078 n.a.u. x1000) and negative (-8.5218 n.a.u. x1000) intensity values. The analysis of NiTi instruments using opto-magnetic imaging spectroscopy indicated changes in the magnetic properties after their instrumentation.
引用
收藏
页数:9
相关论文
共 29 条
  • [1] Mechanism of fracture of NiTi superelastic endodontic rotary instruments
    Javier Gil
    Elisa Rupérez
    Eugenio Velasco
    Conrado Aparicio
    José María Manero
    Journal of Materials Science: Materials in Medicine, 2018, 29
  • [2] Mechanism of fracture of NiTi superelastic endodontic rotary instruments
    Gil, Javier
    Ruperez, Elisa
    Velasco, Eugenio
    Aparicio, Conrado
    Maria Manero, Jose
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2018, 29 (08)
  • [3] Sterilization of rotary NiTi instruments within endodontic sponges
    Chan, H. W. A.
    Tan, K. H.
    Dashper, S. G.
    Reynolds, E. C.
    Parashos, P.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (09) : 850 - 857
  • [4] Papanicolaou Stained Cervical Smear Analysis Using Opto-Magnetic Imaging Spectroscopy
    Papic-Obradovic, Milena
    Jeftic, Branislava
    Matija, Lidija
    FME TRANSACTIONS, 2016, 44 (02): : 212 - 216
  • [5] Opto-magnetic imaging spectroscopy in characterization of the tissues during hyperbaric oxygen therapy
    Sedlar, Mariana
    Nikolic, Gorana V.
    Dragicevic, Aleksandra
    Koruga, Djuro
    VOJNOSANITETSKI PREGLED, 2015, 72 (10) : 922 - 927
  • [6] Feasibility of opto-magnetic resonance spectroscopy at 9.4T
    Just, N.
    Wachsmuth, L.
    Faber, C.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 : 486 - 487
  • [7] Classification of Healthy and Cancer States of Colon Epithelial Tissues Using Opto-magnetic Imaging Spectroscopy
    Dragicevic, Aleksandra
    Matija, Lidija
    Krivokapic, Zoran
    Dimitrijevic, Ivan
    Baros, Marko
    Koruga, Djuro
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2019, 39 (03) : 367 - 380
  • [8] Classification of Healthy and Cancer States of Colon Epithelial Tissues Using Opto-magnetic Imaging Spectroscopy
    Aleksandra Dragicevic
    Lidija Matija
    Zoran Krivokapic
    Ivan Dimitrijevic
    Marko Baros
    Djuro Koruga
    Journal of Medical and Biological Engineering, 2019, 39 : 367 - 380
  • [9] Low-cycle fatigue of rotary NiTi endodontic instruments in hypochlorite solution
    Cheung, Gary S. P.
    Darvell, Brian W.
    DENTAL MATERIALS, 2008, 24 (06) : 753 - 759
  • [10] Comparison between the flexibility of three different types of rotary NiTi endodontic instruments
    Viana, Ana Cecilia Diniz
    Bahia, Maria Guiomar de Azevedo
    Buono, Vicente Tadeu Lopes
    FUNCTIONAL AND STRUCTURAL MATERIALS, 2010, 643 : 61 - +