Clinical application of 3D-printed biodegradable lumbar interbody cage (polycaprolactone/β-tricalcium phosphate) for posterior lumbar interbody fusion

被引:6
|
作者
Liu, Yichao [1 ]
Wu, Hao [2 ]
Bao, Shusen [2 ]
Huang, Hai [2 ]
Tang, Zhen [2 ]
Dong, Hui [2 ]
Liu, Jiaqi [3 ]
Chen, Shengxiu [3 ]
Wang, Ning [2 ]
Wu, Zhigang [1 ]
Zhang, Zhiyong [4 ]
Shi, Lei [1 ,5 ]
Li, Xiaokang [2 ,6 ]
Guo, Zheng [2 ,6 ]
机构
[1] Fourth Mil Med Univ, Xijing Hosp, Dept Orthopaed, Xian, Shaanxi, Peoples R China
[2] Fourth Mil Med Univ, Tangdu Hosp, Dept Orthopaed, Xian, Shaanxi, Peoples R China
[3] Fourth Mil Med Univ, Student Brigade Basic Med Sch, Xian, Shaanxi, Peoples R China
[4] Guangzhou Med Univ, Affiliated Hosp 3, Ctr Translat Res Regenerat Med, Guangzhou, Guangdong, Peoples R China
[5] Fourth Mil Med Univ, Xijing Hosp, Dept Orthopaed, Xian 710032, Shaanxi, Peoples R China
[6] Fourth Mil Med Univ, Tangdu Hosp, Dept Orthopaed, Xian 710038, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
3D printed; biodegradable; cage; clinical trial; lumbar interbody fusion; polycaprolactone (PCL); beta-tricalcium phosphate (beta-TCP); PEEK CAGES; SCAFFOLD; TCP; IMPLANTS;
D O I
10.1002/jbm.b.35244
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel 3D-printed biodegradable cage composed of polycaprolactone (PCL) and beta-tricalcium phosphate (beta-TCP) in a mass ratio of 50:50, with stable resorption patterns and mechanical strength has been developed for lumbar interbody fusion. This is a prospective cohort study to evaluate the short- and mid-term safety and efficacy of this biodegradable cage in posterior lumbar interbody fusion (PLIF) surgery. This was a prospective single-arm pilot clinical trial in 22 patients with a follow-up time of 1, 3, 6, and 12 months, postoperatively. Clinical outcomes were assessed using the Japanese Orthopedic Association Back Pain Evaluation Questionnaire (JOABPEQ) and Visual analogue scale (VAS) for leg pain and low back pain. Radiological examination included X-ray, CT scan, and three-dimensional reconstruction to evaluate surgical indications, intervertebral space height (ISH), intervertebral bone fusion and cage degradation. A total of 22 patients was included, with an average age of 53.5 years. Among 22 patients, one patient lost to follow-up and one patient withdrew from the clinical trial because of cage retropulsion. The remaining 20 patients showed significant improvement in clinical and imaging outcomes compared to the preoperative period. The overall mean VAS for back decreased from 5.85 +/- 0.99 preoperatively to 1.15 +/- 0.86 at the 12-month follow-up (p < .001); the VAS for leg decreased from 5.75 +/- 1.11 to 1.05 +/- 0.76 (p < .001); the JOA score improved from 13.8 +/- 2.64 to 26.45 +/- 2.46 (p < .001). The mean intervertebral space height (ISH) increased from 11.01 +/- 1.75 mm preoperatively to 12.67 +/- 1.89 mm at the 12-month follow-up and the bone fusion reached 95.2% (20/21 disc segments). Partial resorption (inferior to 50% compared with the initial cage size) were found in all cages (21/21). The clinical and radiological assessments showed that the application of 3D-printed biodegradable PCL/beta-TCP cages in PLIF yielded satisfactory results at the 12-month follow-up. In the future, long-term clinical observations and controlled clinical trials are required to further validate the safety and efficacy of this novel cage.
引用
收藏
页码:1398 / 1406
页数:9
相关论文
共 50 条
  • [31] Posterior lumbar interbody fusion - Comment
    Alday, R
    NEUROCIRUGIA, 2001, 12 (05): : 455 - 455
  • [32] Posterior lumbar interbody fusion - Response
    Okuda, Shinya
    JOURNAL OF NEUROSURGERY-SPINE, 2007, 6 (02) : 195 - 195
  • [33] THE FAILED POSTERIOR LUMBAR INTERBODY FUSION
    WETZEL, FT
    LAROCCA, H
    SPINE, 1991, 16 (07) : 839 - 845
  • [34] POSTERIOR LUMBAR INTERBODY FUSION UPDATED
    CLOWARD, RB
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1985, (193) : 16 - 19
  • [35] Paired cylindrical interbody cage fit and facetectomy in posterior lumbar interbody fusion in an Asian population
    Wong, HK
    Goh, JCH
    Goh, PS
    SPINE, 2001, 26 (05) : 572 - 577
  • [36] Subsidence of Metal Interbody Cage After Posterior Lumbar Interbody Fusion With Pedicle Screw Fixation
    Marino, James F.
    ORTHOPEDICS, 2010, 33 (04) : 226 - 227
  • [37] Posterior lumbar interbody fusion and segmental lumbar lordosis
    Kakkar, Rahul
    Sirigiri, P. B. R.
    Howieson, A.
    Raman, A. Siva
    Crawford, R. J.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2007, 17 (02): : 125 - 129
  • [38] Management of lumbar spondylolisthesis: A retrospective analysis of posterior lumbar interbody fusion versus transforaminal lumbar interbody fusion
    Santos, Daniel Encarnacion
    Nurmukhametov, Renat
    Donasov, Medet
    Volovich, Alexander
    Bozkurt, Ismail
    Wellington, Jack
    Lendof, Miguel Espinal
    Peralta, Ismael
    Chaurasia, Bipin
    JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2024, 15 (01): : 99 - 104
  • [39] Comparison of Fusion, Subsidence, and Clinical Results Between 3D-Printed Porous Titanium Cage and Polyetheretherketone Cage in Posterior Lumbar Interbody Fusion: A Minimum of 2 Years Follow-Up
    Yang, Jae Jun
    Kim, Dong -Min
    Park, Sehan
    WORLD NEUROSURGERY, 2023, 177 : E732 - E741
  • [40] Comparison of the early results of transforaminal lumbar interbody fusion and posterior lumbar interbody fusion in symptomatic lumbar instability
    Sakeb, Najmus
    Ahsan, Kamrul
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (03) : 255 - 263