Propagation-based phase-contrast imaging of the breast: image quality and the effect of X-ray energy and radiation dose

被引:1
|
作者
Gunaseelan, Indusaa [1 ]
Zadeh, Alaleh Amin [2 ,3 ]
Arhatari, Benedicta [4 ]
Maksimenko, Anton [4 ]
Hall, Christopher [4 ]
Hausermann, Daniel [4 ]
Kumar, Beena [5 ]
Fox, Jane [6 ]
Quiney, Harry [7 ]
Lockie, Darren [8 ]
Lewis, Sarah [1 ]
Brennan, Patrick [1 ]
Gureyev, Timur [7 ]
Taba, Seyedamir Tavakoli [1 ]
机构
[1] Univ Sydney, Fac Med & Hlth, Discipline Med Imaging Sci, Camperdown, NSW, Australia
[2] Australian Natl Univ, Sch Phys, Canberra, ACT, Australia
[3] Univ Sydney, Camperdown, NSW, Australia
[4] Australian Natl Sci & Technol Org, Australian Synchrotron, Clayton, Vic, Australia
[5] Monash Hlth, Monash Hlth Pathol, Clayton, Vic, Australia
[6] Monash Univ, Fac Med Nursing & Hlth Sci, Clayton, Vic, Australia
[7] Univ Melbourne, Sch Phys, Parkville, Vic, Australia
[8] Eastern Hlth, Maroondah BreastScreen, Ringwood, Vic, Australia
来源
BRITISH JOURNAL OF RADIOLOGY | 2023年 / 96卷 / 1150期
基金
英国医学研究理事会;
关键词
OPTIMIZATION; TOMOGRAPHY; CT;
D O I
10.1259/bjr.20221189
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Propagation-based phase-contrast computed tomography (PB-CT) is a new imaging technique that exploits refractive and absorption properties of X-rays to enhance soft tissue contrast and improve image quality. This study compares image quality of PB-CT and absorption-based CT (AB-CT) for breast imaging while exploring X-ray energy and radiation dose. Methods: Thirty-nine mastectomy samples were scanned at energy levels of 28-34keV using a flat panel detector at radiation dose levels of 4mGy and 2mGy. Image quality was assessed using signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), spatial resolution (res) and visibility (vis). Statistical analysis was performed to compare PB-CT images against their corresponding AB-CT images scanned at 32keV and 4mGy. Results: The PB-CT images at 4mGy, across nearly all energy levels, demonstrated superior image quality than AB-CT images at the same dose. At some energy levels, the 2mGy PB-CT images also showed better image quality in terms of CNR/Res and vis compared to the 4mGy AB-CT images. At both investigated doses, SNR and SNR/res were found to have a statistically significant difference across all energy levels. The difference in vis was statistically significant at some energy levels. Conclusion: This study demonstrates superior image quality of PB-CT over AB-CT, with X-ray energy playing a crucial role in determining image quality parameters. Advances in knowledge: Our findings reveal that standard dose PB-CT outperforms standard dose AB-CT across all image quality metrics. Additionally, we demonstrate that low dose PB-CT can produce superior images compared to standard dose AB-CT in terms of CNR/Res and vis.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] X-ray phase-contrast imaging
    Endrizzi, Marco
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 88 - 98
  • [32] Phase-contrast X-ray CT image of breast tumor
    Institute of Clinical Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba-shi, Ibaraki 305-8575, Japan
    不详
    J. Synchrotron Radiat., 3 (1133-1135):
  • [33] Image Fusion in X-Ray Differential Phase-Contrast Imaging
    Haas, W.
    Polyanskaya, M.
    Bayer, F.
    Goedel, K.
    Hofmann, H.
    Rieger, J.
    Ritter, A.
    Weber, T.
    Wucherer, L.
    Durst, J.
    Michel, T.
    Anton, G.
    Hornegger, J.
    MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [34] Phase-contrast X-ray CT image of breast tumor
    Takeda, T
    Momose, A
    Ueno, E
    Itai, Y
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1133 - 1135
  • [35] The projection approximation and edge contrast for x-ray propagation-based phase contrast imaging of a cylindrical edge
    Morgan, K. S.
    Siu, K. K. W.
    Paganin, D. M.
    OPTICS EXPRESS, 2010, 18 (10): : 9865 - 9878
  • [36] Potential of propagation-based synchrotron X-ray phase-contrast computed tomography for cardiac tissue engineering
    Izadifar, Mohammad (mohammad.izadifar@usask.ca), 1600, International Union of Crystallography, 5 Abbey Road, Chester, CH1 2HU, United Kingdom (24):
  • [37] Potential of propagation-based synchrotron X-ray phase-contrast computed tomography for cardiac tissue engineering
    Izadifar, Mohammad
    Babyn, Paul
    Chapman, Dean
    Kelly, Michael E.
    Chen, Xiongbiao
    JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 : 842 - 853
  • [38] Investigation on the Dependency of Phase Retrieval Accuracy Versus Edge Enhancement to the Noise Ratio of X-ray Propagation-Based Phase-Contrast Imaging
    Zhang, Lin
    Zhao, Huijuan
    Jiang, Jingying
    Zhang, Limin
    Li, Jiao
    Gao, Feng
    Zhou, Zhongxing
    MICROSCOPY AND MICROANALYSIS, 2019, 25 (05) : 1201 - 1212
  • [39] Computational techniques in propagation-based x-ray phase imaging
    Petruccelli, Jonathan C.
    Tahir, Sajjad
    Bashir, Sajid
    Pan, Adam
    Tian, Lei
    Xu, Ling
    MacDonald, C. A.
    Barbastathis, George
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS III, 2014, 9209
  • [40] Image Quality and Radiation Dose in Propagation Based Phase Contrast Mammography with a Microfocus X-ray Tube: A Phantom Study
    Castriconi, Roberta
    Mettivier, Giovanni
    Russo, Paolo
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 618 - 624