Strategies to enhance figures of merit in ICP-ToF-MS

被引:10
|
作者
Lockwood, T. E. [1 ]
de Vega, R. Gonzalez [2 ]
Du, Z. [3 ]
Schlatt, L. [4 ]
Xu, X. [3 ]
Clases, D. [2 ]
机构
[1] Univ Technol Sydney, Hyphenated Mass Spectrometry Lab, Ultimo, NSW, Australia
[2] Karl Franzens Univ Graz, Inst Chem, Graz, Austria
[3] Univ Technol Sydney, Fac Engn & Informat Technol, Sch Biomed Engn, Ultimo, NSW, Australia
[4] Nu Instruments, Wrexham, Wales
关键词
LASER-ABLATION; MASS SPECTROMETRY;
D O I
10.1039/d3ja00288h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Inductively coupled plasma with time-of-flight mass spectrometry (ICP-ToF-MS) is currently setting new benchmarks for the analysis of single particles (SP) and elemental mapping using laser ablation (LA). The rapid collection of full elemental mass spectra promotes non-target approaches, fast imaging as well as inquiries of particle composition. However, one shortcoming often associated with ICP-ToF-MS is a lack of detection power due to lower duty cycles relative to sequentially operating mass analysers targeting only a limited number of elements. The sensitivity of ICP-ToF-MS can be increased using two strategies, which are detailed in this study. First, instead of analysing full mass spectra, elements in the low and high mass ranges were excluded from analysis using a Bradbury-Nielsen gate. The resulting restricted mass range was acquired up to 5 times faster increasing duty cycles and sensitivity accordingly. Second, isotopes of polyisotopic elements recorded simultaneously were accumulated to increase signal to noise ratios. In a proof of concept, we applied SP ICP-ToF-MS for the first time to characterise upconversion nanoparticles (UCNPs) that contained Gd and Yb. Both signal amplification strategies were combined and the consequences for detection limits and signal to noise ratios were considered and compared to a standard method. Sensitivities were increased up to factor 27 when accumulating all Gd and Yb isotopes at 177 kHz, and size detection limits decreased by a factor of approximately 3. Improved figures of merit promoted more accurate investigations of UCNPs, which were characterised regarding size distributions and composition. As a second application, we demonstrated the utility of the described strategies in LA-ICP-ToF-MS. Mo and Se were targeted as relatively rare elements in rat brain tissue. Increased acquisition frequencies of 180 kHz and isotope accumulation resulted in drastically improved signal to noise ratios and enabled the mapping of both elements while still considering relevant neuroanatomical elements such as Fe and Zn. Two strategies can improve figures of merit in ICP-ToF-MS: the use of a Bradbury-Nielson gate to improve duty cycles and, the post-analysis accumulation of isotopic signals from polyisotopic elements.
引用
收藏
页码:227 / 234
页数:8
相关论文
共 50 条
  • [31] Hierarchical cellular ferroelectric metamaterials: A design motif to enhance multifunctional figures of merit
    Shi, J.
    Akbarzadeh, A. H.
    COMPOSITE STRUCTURES, 2020, 250
  • [32] A bottom-up route to enhance thermoelectric figures of merit in graphene nanoribbons
    Sevincli, Haldun
    Sevik, Cem
    Cagin, Tahir
    Cuniberti, Gianaurelio
    SCIENTIFIC REPORTS, 2013, 3
  • [33] Erratum: A bottom-up route to enhance thermoelectric figures of merit in graphene nanoribbons
    Hâldun Sevinçli
    Cem Sevik
    Tahir Çağın
    Gianaurelio Cuniberti
    Scientific Reports, 3
  • [34] Testing textiles using the LA-ICP-MS-TOF method
    Institute of General and Ecological Chemistry, Technical University of Lódź, ul. Zeromskiego 116, 90-924 Lódź, Poland
    不详
    不详
    Fibres Text. East. Eur., 2006, 4 (87-90):
  • [36] ICP-MS-BASED STRATEGIES FOR PROTEIN QUANTIFICATION
    Wang, Meng
    Feng, Wei-Yue
    Zhao, Yu-Liang
    Chai, Zhi-Fang
    MASS SPECTROMETRY REVIEWS, 2010, 29 (02) : 326 - 348
  • [37] Ni speciation in tea infusions by monolithic chromatography-ICP-MS and Q-TOF-MS
    Scancar, Janez
    Zuliani, Tea
    Zigon, Dusan
    Milacic, Radmila
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (06) : 2041 - 2051
  • [38] Single cell-asymmetrical flow field-flow fractionation/ICP-time of flight-mass spectrometry (sc-AF4/ICP-ToF-MS): an efficient alternative for the cleaning and multielemental analysis of individual cells
    Chronakis, Michail Ioannis
    Von Der Au, Marcus
    Meermann, Bjoern
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (12) : 2691 - 2700
  • [39] Choosing internal standards based on a multivariate analysis approach with ICP(TOF)MS
    Finley-Jones, Haley J.
    Molloy, John L.
    Holcombe, James A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (09) : 1214 - 1222
  • [40] Ni speciation in tea infusions by monolithic chromatography—ICP-MS and Q-TOF-MS
    Janez Ščančar
    Tea Zuliani
    Dušan Žigon
    Radmila Milačič
    Analytical and Bioanalytical Chemistry, 2013, 405 : 2041 - 2051