Rapid T2*-weighted MRI using multishot EPI with retrospective motion and phase correction in the emergency department

被引:0
|
作者
Li, Zhiqiang [1 ,3 ]
Ooi, Melvyn B. [2 ]
Murchison, James A. [1 ]
Karis, John P. [1 ]
机构
[1] Barrow Neurol Inst, Dept Neuroradiol, Phoenix, AZ USA
[2] Philips Healthcare, Houston, TX USA
[3] St Josephs Hosp, Barrow Neurol Inst, Neurosci Publicat, 350 W Thomas Rd, Phoenix, AZ 85013 USA
关键词
emergency department; motion correction; multishot EPI; phase correction; T*(2)-weighted MRI; CEREBRAL MICROBLEEDS; ECHO; HEMORRHAGE; BRAIN; SENSE;
D O I
10.1002/mrm.29809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Brain MRI is increasingly used in the emergency department (ED), where T*(2)-weighted MRI is an essential tool for detecting hemorrhage and stroke. The goal of this study was to develop a rapid T*(2)-weighted MRI technique capable of correcting motion-induced artifacts, thereby simultaneously improving scan time and motion robustness for ED applications.Methods: A 2D gradient-echo (GRE)-based multishot EPI (msEPI) technique was implemented using a navigator echo for estimating motion-induced errors. Bulk rigid head motion and phase errors were retrospectively corrected using an iterative conjugate gradient approach in the reconstruction pipeline. Three volunteers and select patients were imaged at 3 T and/or 1.5 T with an approximately 1-min full-brain protocol using the proposed msEPI technique and compared to an approximately 3-min standard-of-care GRE protocol to examine its performance.Results: Data from volunteers demonstrated that in-plane motion artifacts could be effectively corrected with the proposed msEPI technique, and through-plane motion artifacts could be mitigated. Patient images were qualitatively reviewed by one radiologist without a formal statistical analysis. These results suggested the proposed technique could correct motion-induced artifacts in the clinical setting. In addition, the conspicuity of susceptibility-related lesions using the proposed msEPI technique was comparable, or improved, compared to GRE.Conclusion: A 1-min full-brain T*(2)-weighted MRI technique was developed using msEPI with a navigator echo to correct motion-induced errors. Preliminary clinical results suggest faster scans and improved motion robustness and lesion conspicuity make msEPI a competitive alternative to traditional T*(2)-weighted MRI techniques for brain studies in the ED.
引用
收藏
页码:2500 / 2509
页数:10
相关论文
共 50 条
  • [11] Free-breathing myocardial T2*mapping using GRE-EPI and automatic Non-rigid motion correction
    Jin, Ning
    da Silveira, Juliana Serafim
    Jolly, Marie-Pierre
    Firmin, David N.
    Mathew, George
    Lamba, Nathan
    Subramanian, Sharath
    Pennell, Dudley J.
    Raman, Subha V.
    Simonetti, Orlando P.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [12] Free-breathing myocardial T2* mapping using GRE-EPI and automatic Non-rigid motion correction
    Ning Jin
    Juliana Serafim da Silveira
    Marie-Pierre Jolly
    David N. Firmin
    George Mathew
    Nathan Lamba
    Sharath Subramanian
    Dudley J. Pennell
    Subha V. Raman
    Orlando P. Simonetti
    Journal of Cardiovascular Magnetic Resonance, 17
  • [13] Free-breathing myocardial T2* mapping using GRE-EPI and automatic non-rigid motion correction
    Ning Jin
    Marie-Pierre Jolly
    Subha V Raman
    Orlando P Simonetti
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [14] Artifact free T2*-weighted imaging at high spatial resolution using segmented EPI sequences
    Heiler, Patrick Michael
    Schmitter, Sebastian
    Schad, Lothar Rudi
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2010, 20 (03): : 166 - 174
  • [15] Rapid simultaneous acquisition of T1 and T2 mapping images using multishot double spin-echo EPI and automated variations of TR and TE (ms-DSEPI-T12)
    Liu, Xin
    Feng, Yi
    Lu, Zheng-Rong
    Morrell, Glen
    Jeong, Eun-Kee
    NMR IN BIOMEDICINE, 2010, 23 (01) : 97 - 104
  • [16] Model for the correction of motion-induced phase errors in multishot diffusion-weighted-MRI of the head: Are cardiac-motion-induced phase errors reproducible from beat-to-beat?
    O'Halloran, R. L.
    Holdsworth, S.
    Aksoy, M.
    Bammer, R.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (02) : 430 - 440
  • [17] Navigator-Guided Motion and B0 Correction of T2*-weighted MRI Improves Multiple Sclerosis Cortical Lesion Detection
    Beck, E. S.
    Liu, J.
    Filippini, S.
    van Gelderen, P.
    de Zwart, J. A.
    Norato, G.
    Sati, P.
    Al-Louzi, O.
    Kolb, H.
    Donadieu, M.
    Morrison, M.
    Duyn, J. H.
    Reich, D. S.
    MULTIPLE SCLEROSIS JOURNAL, 2021, 27 (1_SUPPL) : 70 - 71
  • [18] Cerebral blood volume measurements by rapid contrast infusion and T2*-weighted echo planar MRI
    Tudorica, A
    Li, HF
    Hospod, F
    Delucia-Deranja, E
    Huang, W
    Patlak, CS
    Newman, GC
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1145 - 1157
  • [19] Accelerated Simultaneous T2 and T2* Mapping of Multiple Sclerosis Lesions Using Compressed Sensing Reconstruction of Radial RARE-EPI MRI
    Herrmann, Carl J. J.
    Starke, Ludger
    Millward, Jason M.
    Kuchling, Joseph
    Paul, Friedemann
    Niendorf, Thoralf
    TOMOGRAPHY, 2023, 9 (01) : 299 - 314
  • [20] Reducing motion sensitivity in 3D high-resolution T2*-weighted MRI by navigator-based motion and nonlinear magnetic field correction
    Liu, Jiaen
    van Gelderen, Peter
    de Zwart, Jacco A.
    Duyn, Jeff H.
    NEUROIMAGE, 2020, 206