Rapid T2*-weighted MRI using multishot EPI with retrospective motion and phase correction in the emergency department

被引:0
|
作者
Li, Zhiqiang [1 ,3 ]
Ooi, Melvyn B. [2 ]
Murchison, James A. [1 ]
Karis, John P. [1 ]
机构
[1] Barrow Neurol Inst, Dept Neuroradiol, Phoenix, AZ USA
[2] Philips Healthcare, Houston, TX USA
[3] St Josephs Hosp, Barrow Neurol Inst, Neurosci Publicat, 350 W Thomas Rd, Phoenix, AZ 85013 USA
关键词
emergency department; motion correction; multishot EPI; phase correction; T*(2)-weighted MRI; CEREBRAL MICROBLEEDS; ECHO; HEMORRHAGE; BRAIN; SENSE;
D O I
10.1002/mrm.29809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Brain MRI is increasingly used in the emergency department (ED), where T*(2)-weighted MRI is an essential tool for detecting hemorrhage and stroke. The goal of this study was to develop a rapid T*(2)-weighted MRI technique capable of correcting motion-induced artifacts, thereby simultaneously improving scan time and motion robustness for ED applications.Methods: A 2D gradient-echo (GRE)-based multishot EPI (msEPI) technique was implemented using a navigator echo for estimating motion-induced errors. Bulk rigid head motion and phase errors were retrospectively corrected using an iterative conjugate gradient approach in the reconstruction pipeline. Three volunteers and select patients were imaged at 3 T and/or 1.5 T with an approximately 1-min full-brain protocol using the proposed msEPI technique and compared to an approximately 3-min standard-of-care GRE protocol to examine its performance.Results: Data from volunteers demonstrated that in-plane motion artifacts could be effectively corrected with the proposed msEPI technique, and through-plane motion artifacts could be mitigated. Patient images were qualitatively reviewed by one radiologist without a formal statistical analysis. These results suggested the proposed technique could correct motion-induced artifacts in the clinical setting. In addition, the conspicuity of susceptibility-related lesions using the proposed msEPI technique was comparable, or improved, compared to GRE.Conclusion: A 1-min full-brain T*(2)-weighted MRI technique was developed using msEPI with a navigator echo to correct motion-induced errors. Preliminary clinical results suggest faster scans and improved motion robustness and lesion conspicuity make msEPI a competitive alternative to traditional T*(2)-weighted MRI techniques for brain studies in the ED.
引用
收藏
页码:2500 / 2509
页数:10
相关论文
共 50 条
  • [1] Retrospective Motion Correction in Multishot MRI using Generative Adversarial Network
    Muhammad Usman
    Siddique Latif
    Muhammad Asim
    Byoung-Dai Lee
    Junaid Qadir
    Scientific Reports, 10
  • [2] Retrospective Motion Correction in Multishot MRI using Generative Adversarial Network
    Usman, Muhammad
    Latif, Siddique
    Asim, Muhammad
    Lee, Byoung-Dai
    Qadir, Junaid
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [3] Prospective motion correction in 2D multishot MRI using EPI navigators and multislice-to-volume image registration
    Hoinkiss, Daniel Christopher
    Porter, David Andrew
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (06) : 2127 - 2135
  • [4] T2*-weighted imaging for detection of intracranial silicone oil in MRI obtained with motion correction sequences
    Ryuta Yasuda
    Masayuki Maeda
    Kenichi Takada
    Katsuhiro Inoue
    Masataka Sugao
    Hidenori Suzuki
    Egyptian Journal of Neurosurgery, 40 (1)
  • [5] An improved method for retrospective motion correction in quantitative T2*mapping
    Noeth, Ulrike
    Volz, Steffen
    Hattingen, Elke
    Deichrnann, Ralf
    NEUROIMAGE, 2014, 92 : 106 - 119
  • [6] Physics-Aware Motion Simulation For T2*-Weighted Brain MRI
    Eichhorn, Hannah
    Hammernik, Kerstin
    Spieker, Veronika
    Epp, Samira M.
    Rueckert, Daniel
    Preibisch, Christine
    Schnabel, Julia A.
    SIMULATION AND SYNTHESIS IN MEDICAL IMAGING, SASHIMI 2023, 2023, 14288 : 42 - 52
  • [7] Temperature Mapping Using Combined T2 and Diffusion Weighted MRI of Encapsulated Phase Change Materials
    Skuntz, Matthew E.
    Anderson, Ryan
    Codd, Sarah L.
    Seymour, Joseph D.
    APPLIED MAGNETIC RESONANCE, 2023, 54 (11-12) : 1589 - 1605
  • [8] Temperature Mapping Using Combined T2 and Diffusion Weighted MRI of Encapsulated Phase Change Materials
    Matthew E. Skuntz
    Ryan Anderson
    Sarah L. Codd
    Joseph D. Seymour
    Applied Magnetic Resonance, 2023, 54 : 1589 - 1605
  • [9] Targeted rapid knee MRI exam using T2 shuffling
    Tamir, Jonathan I.
    Taviani, Valentina
    Alley, Marcus T.
    Perkins, Becki C.
    Hart, Lori
    O'Brien, Kendall
    Wishah, Fidaa
    Sandberg, Jesse K.
    Anderson, Michael J.
    Turek, Javier S.
    Willke, Theodore L.
    Lustig, Michael
    Vasanawala, Shreyas S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (07) : E195 - E204
  • [10] Retrospective T2 quantification from conventional weighted MRI of the prostate based on deep learning
    Sun, Haoran
    Wang, Lixia
    Daskivich, Timothy
    Qiu, Shihan
    Han, Fei
    D'Agnolo, Alessandro
    Saouaf, Rola
    Christodoulou, Anthony G.
    Kim, Hyung
    Li, Debiao
    Xie, Yibin
    FRONTIERS IN RADIOLOGY, 2023, 3