Determination of Heat Transfer Correlations for Fluids Flowing through Plate Heat Exchangers Needed for Online Monitoring of District Heat Exchanger Fouling

被引:1
|
作者
Romanowicz, Tomasz [1 ]
Taler, Jan [1 ]
Jaremkiewicz, Magdalena [2 ]
Sobota, Tomasz [2 ]
机构
[1] Cracow Univ Technol, Dept Energy, PL-31155 Krakow, Poland
[2] Cracow Univ Technol, Dept Thermal Proc Air Protect & Waste Utilisat, PL-31155 Krakow, Poland
关键词
plate heat exchangers; thermal resistance of the fouling; Nusselt number correlation; Wilson method; THERMAL-RESISTANCE;
D O I
10.3390/en16176264
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This article deals with the problem of estimating the degree of fouling of plate heat exchangers (PHEs) used in district heating substations (where the working medium is water). A method for calculating the thermal resistance of fouling is proposed based on a comparison of the thermal resistance of a fouled and clean heat exchanger. The thermal resistance of the heat exchanger for both fouled and clean apparatuses is determined as the inverse of their overall heat transfer coefficient. In the method, the heat transfer coefficients necessary to determine the overall heat transfer coefficient of the clean exchanger are calculated using a modified Wilson method. Moreover, the heat transfer coefficients on the clean heat exchanger plates' cold water side are determined based on experimental tests. The computational algorithm presented in this paper will make it possible to develop software to monitor and thus optimise the operation of district heating substations.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Heat transfer correlations for vertical mantle heat exchangers
    Shah, LJ
    SOLAR ENERGY, 2000, 69 (1-6) : 157 - 171
  • [32] Heat transfer correlations for vertical mantle heat exchangers
    Shah, L.J.
    2001, Elsevier Ltd (69)
  • [33] Prediction of heat transfer correlations for compact heat exchangers
    D. Taler
    Forschung im Ingenieurwesen, 2005, 69 : 137 - 150
  • [34] Prediction of heat transfer correlations for compact heat exchangers
    Taler, D
    FORSCHUNG IM INGENIEURWESEN-ENGINEERING RESEARCH, 2005, 69 (03): : 137 - 150
  • [35] Interaction of Heat Transfer Enhancement and Fouling in Operating Heat Exchangers
    Ishiyama, Edward Masato
    Pugh, Simon John
    Watkinson, Alan Paul
    HEAT TRANSFER ENGINEERING, 2024, 45 (15) : 1327 - 1337
  • [36] A Study on Characteristics of Cooling Heat Transfer of Supercritical Pressure Fluids in a Plate Heat Exchanger
    Mori, Hideo
    Nakamura, Shin
    Ono, Fuka
    Kariya, Keishi
    Umezawa, Shuichi
    HEAT TRANSFER ENGINEERING, 2016, 37 (7-8) : 659 - 667
  • [37] CRYSTALLIZATION FOULING IN PLATE HEAT-EXCHANGERS
    BANSAL, B
    MULLERSTEINHAGEN, H
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1993, 115 (03): : 584 - 591
  • [38] PREVENTING FOULING IN PLATE HEAT-EXCHANGERS
    CROSS, PH
    CHEMICAL ENGINEERING, 1979, 86 (01) : 87 - 90
  • [39] Flow and heat transfer correlations for porous fin in a plate-fin heat exchanger
    Kim, SY
    Paek, JW
    Kang, BH
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2000, 122 (03): : 572 - 578
  • [40] Plate heat exchangers - fouling factor criterion
    1600, Industrial Publications, Bombay, India (30):