Non-Contact and Self-Calibrated Photopyroelectric Method for Complete Thermal Characterization of Porous Materials

被引:0
|
作者
Swapna, Mohanachandran Nair Sindhu [1 ]
Tripon, Carmen [2 ]
Gutt, Robert [2 ]
Farcas, Alexandra [2 ]
Bojan, Marcel [2 ]
Korte, Dorota [1 ]
Kacso, Irina [2 ]
Franko, Mladen [1 ]
Dadarlat, Dorin [2 ]
机构
[1] Univ Nova Gorica, Lab Environm & Life Sci, Vipavska 13, SL-5000 Nova Gorica, Slovenia
[2] Natl R&D Inst Isotop & Mol Technol, Donat 67-103, Cluj Napoca 400293, Romania
关键词
photopyroelectric calorimetry; thermal parameters; porous materials; CONDUCTIVITY;
D O I
10.3390/ma16155242
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A general theory of a photopyroelectric (PPE) configuration, based on an opaque sample and transparent pyroelectric sensor, backing and coupling fluids is developed. A combined back-front detection investigation, based on a frequency scan of the phase of the PPE signals, followed by a self-normalization of the phases' behavior, leads to the possibility of simultaneously measuring both thermal effusivity and diffusivity of a solid sample. A particular case of this configuration, with no coupling fluid at the sample/backing interface and air instead of coupling fluid at the sample/sensor interface (non-contact method) is suitable for simultaneous measurement ofboth thermal diffusivity and effusivity (in fact complete thermal characterization) of porous solids. Compared with the already proposed configurations for investigations of porous materials, this novel configuration makes use of a fitting procedure with only one fitting parameter, in order to guarantee the uniqueness of the solution. The porous solids belong to a class of materials which are by far not easy to be investigated using PPE. To the best of our knowledge, porous materials represent the only type of compounds, belonging to condensed matter, which were not taken into consideration (until recently) as potential samples for PPE calorimetric investigations. Consequently, the method proposed in this paper complete the area of applications of the PPE method. Applications on some porous building materials and cellulose-based samples validate the theory.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Non-destructive and non-contact materials evaluation by means of the optodynamic method
    Hrovatin, R
    Mozina, J
    INSIGHT, 2000, 42 (12) : 801 - 804
  • [22] Non-destructive and non-contact materials evaluation by means of the optodynamic method
    Hrovatin, R.
    Mozina, J.
    Insight: Non-Destructive Testing and Condition Monitoring, 2000, 42 (12): : 801 - 808
  • [23] Non-contact method for characterization of small size thermoelectric modules
    Manno, Michael
    Yang, Bao
    Bar-Cohen, Avram
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (08):
  • [24] Non-contact characterization of static paper materials using a photorefractive interferometer
    Lafond, EF
    Gerhardstein, JP
    Brodeur, PH
    PROCESS CONTROL AND SENSORS FOR MANUFACTURING II, 1999, 3589 : 30 - 41
  • [25] Non-contact RF Characterization of Reinforced Carbon Fiber Composite Materials
    Ciampalini, Chiara
    Usai, Pierpaolo
    Nenna, Guido
    Costa, Filippo
    Monorchio, Agostino
    2018 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2018, : 1065 - 1066
  • [26] High throughput integrated thermal characterization with non-contact optical calorimetry
    Hou, Sichao
    Huo, Ruiqing
    Su, Ming
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (10):
  • [27] The choice of a method for non-contact assessment of the composition of briquetted charge materials
    Kul'chitskii, A. A.
    Kashin, D. A.
    INTERNATIONAL SCIENTIFIC CONFERENCE ON APPLIED PHYSICS, INFORMATION TECHNOLOGIES AND ENGINEERING (APITECH-2019), 2019, 1399
  • [28] Estimating the Thermal Properties of Flat Products by a New Non-contact Method
    Michalak, Marina
    Wiecek, Boguslaw
    FIBRES & TEXTILES IN EASTERN EUROPE, 2008, 16 (04) : 72 - 77
  • [29] Estimating the thermal properties of flat products by a new non-contact method
    Department of Fibre Physics and Textile Metrology, Technical University of Lódź Poland, ul. Zeromskiego 115, 90-543 Lódź, Poland
    不详
    Fibres Text. East. Eur., 2008, 4 (72-77):
  • [30] Non-Contact Measurement of Thermal Diffusivity in Ion-Implanted Nuclear Materials
    Hofmann, F.
    Mason, D. R.
    Eliason, J. K.
    Maznev, A. A.
    Nelson, K. A.
    Dudarev, S. L.
    SCIENTIFIC REPORTS, 2015, 5