Navigation Guided Biopsy Is as Effective as Frame-Based Stereotactic Biopsy

被引:5
|
作者
Lim, Dae Hyun [1 ]
Kim, So Yeon [1 ]
Na, Young Cheol [1 ]
Cho, Jin Mo [1 ]
机构
[1] Catholic Kwandong Univ, Int St Marys Hosp, Dept Neurosurg, Incheon 22711, South Korea
来源
JOURNAL OF PERSONALIZED MEDICINE | 2023年 / 13卷 / 05期
关键词
navigation; biopsy; frameless steretaxy; DIAGNOSTIC YIELD; ACCURACY; EXPERIENCE; SAFETY;
D O I
10.3390/jpm13050708
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Stereotactic biopsy is a standard procedure for brain biopsy. However, with advances in technology, navigation-guided brain biopsy has become a well-established alternative. Previous studies have shown that frameless stereotactic brain biopsy is as effective and safe as frame-based stereotactic brain biopsy is. In this study, the authors evaluate the diagnostic yield and complication rate of frameless intracranial biopsy. Materials and Methods: We reviewed data from biopsy performed patients between March 2014 and April 2022. We retrospectively reviewed medical records, including imaging studies. Various intracerebral lesions were biopsied. Diagnostic yield and post-operative complications were compared with those of frame-based stereotactic biopsy.Results: Forty-two frameless navigation-guided biopsy were performed, and the most common pathology was primary central nervous system lymphoma (35.7%), followed by glioblastoma (33.3%), and anaplastic astrocytomas (16.7%), respectively. The diagnostic yield was 100%. Post-operative intracerebral hematoma occurred in 2.4% of cases, but it was not symptomatic. Thirty patients underwent frame-based stereotactic biopsy, and the diagnostic yield was 96.7%. There was no difference in diagnostic rates between two methods (Fisher's exact test, p = 0.916).Conclusions: Frameless navigation-guided biopsy is as effective as frame-based stereotactic biopsy is, without causing further complications. We consider that frame-based stereotactic biopsy is no longer needed if frameless navigation-guided biopsy is used. A further study will be needed to generalize our results.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Frame-Based Stereotactic Biopsy- A Single Neurosurgeon Experience of 604 Diagnostic Procedures and Literature Review
    Samanci, Yavuz
    Akyoldas, Goktug
    Lav, Ahmet Hakan
    Peker, Selcuk
    TURKISH NEUROSURGERY, 2022, 32 (06) : 968 - 980
  • [32] Safety and efficacy of frameless and frame-based intracranial biopsy techniques
    A. Savas
    Y. Kanpolat
    Acta Neurochirurgica, 2008, 150 : 737 - 737
  • [33] Safety and efficacy of frameless and frame-based intracranial biopsy techniques
    Savas, A.
    Kanpolat, Y.
    ACTA NEUROCHIRURGICA, 2008, 150 (07) : 737 - 737
  • [34] Safety and efficacy of frameless and frame-based intracranial biopsy techniques
    R. Dammers
    I. K. Haitsma
    J. W. Schouten
    J. M. Kros
    C. J. J. Avezaat
    A. J. P. E. Vincent
    Acta Neurochirurgica, 2008, 150
  • [35] Safety and efficacy of frameless and frame-based intracranial biopsy techniques
    Dammers, R.
    Haitsma, I. K.
    Schouten, J. W.
    Kros, J. M.
    Avezaat, C. J. J.
    Vincent, A. J. P. E.
    ACTA NEUROCHIRURGICA, 2008, 150 (01) : 23 - 29
  • [36] Stereotactic neuroendoscopy using frame-based, frameless BrainLab navigation and PACS
    Novak, Z
    Chrastina, J
    Riha, I
    Pohanka, M
    Jancalek, R
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1340 - 1340
  • [37] Accuracy Comparison between Frameless Biopsy and Frame-Based Biopsy: A Retrospective Study of a Case Series
    Braga, Henrique Moura
    Dellaretti, Marcos Antonio
    Faria, Marcello Penholate
    de Almeida, Julio Cezar
    do Nascimento, Leyzeane Marques
    BRAZILIAN NEUROSURGERY-ARQUIVOS BRASILEIROS DE NEUROCIRURGIA, 2023, 42 (03): : E233 - E238
  • [38] Yield and complications of frame-based and frameless stereotactic brain biopsy - The value of intra-operative histological analysis
    Livermore, Laurent J.
    Ma, Ruichong
    Bojanic, Stana
    Pereira, Erlick A. C.
    BRITISH JOURNAL OF NEUROSURGERY, 2014, 28 (05) : 637 - 644
  • [39] Stereotactic needle guided procedures: Frame-based versus frameless systems
    Benvenuti, L
    Gagliardi, R
    Carnesecchi, S
    12TH EUROPEAN CONGRESS OF NEUROSURGERY (EANS), PROCEEDINGS, 2003, : 963 - 967
  • [40] Spectroscopy-supported frame-based image-guided stereotactic biopsy of parenchymal brain lesions: Comparative evaluation of diagnostic yield and diagnostic accuracy
    Chernov, Mikhail F.
    Muragaki, Yoshihiro
    Ochiai, Taku
    Taira, Takaomi
    Ono, Yuko
    Usukura, Masao
    Maruyama, Takashi
    Nakaya, Kotaro
    Nakamura, Ryoichi
    Iseki, Hiroshi
    Kubo, Osami
    Hori, Tomokatsu
    Takakura, Kintomo
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2009, 111 (06) : 527 - 535