Energy, exergy, exergoeconomic, and environmental (4E) analyses of a novel combined cooling and power system with phosphoric acid fuel cell and Kalina cycle

被引:7
|
作者
Einanlou, Mehrdad [1 ]
Mehregan, Mahmood [1 ]
Hashemian, Seyed Majid [1 ]
机构
[1] Shahrood Univ Technol, Fac Mech Engn, POB 3619995161, Shahrood, Iran
关键词
Steam methane reforming; Phosphoric acid fuel cell; Kalina cycle; Absorption chiller; Cogeneration; 4E analyses; ORGANIC RANKINE-CYCLE; HYDROGEN-PRODUCTION; STIRLING ENGINE; PERFORMANCE; DRIVEN; HEAT; SOFC; OPTIMIZATION; METHANOL;
D O I
10.1016/j.applthermaleng.2022.119877
中图分类号
O414.1 [热力学];
学科分类号
摘要
The use of combined energy systems with high efficiency, based on conventional or renewable energy sources can be a suitable option to overcome the existing limitations in the field of energy and reduce environmental pollutions. Therefore, choosing a fuel cell as the prime mover and also using its wasted heat in combined systems can increase the overall efficiency of the system and reduce fuel consumption, greenhouse gas emissions, and operating costs. In this study, a novel combined cooling and power system including a Kalina cycle and a single-effect water -ammonia absorption chiller is proposed to recover waste heat from the phosphoric acid fuel cell. In most of the previous works, a heat recovery system has been used for the phosphoric acid fuel cell, while in this study, two heat recovery systems (Kalina cycle and absorption chiller) with a new arrangement have been used with the fuel cell and analyzed from energy, exergy, exergoeconomic, and environmental perspectives. Impacts of current density, fuel price and carbon price on system performance have been studied and the net power and cooling load of system are evaluated. The results show that, the energy and exergy efficiencies, the unit cost of system, and the carbon dioxide emission penalty cost are 54.27 %, 45.48 %, 0.162 $ kW -1h- 1, and 9.557 $ h-1, respectively. Also, the carbon dioxide emissions decrease up to 147.6 g kW-1 h-1 and energy and exergy effi-ciencies increase to 52.32 % and 33.06 %, respectively compared to the operation of fuel cell alone. Also, the exergeoeconomic factors of fuel cell, inverter and turbine are 77.33 %, 57.41 % and 52.36 %, respectively, which are higher than other equipment. The highest exergy destruction belongs to the after-burner, which is about 20.35 % of the total exergy destruction of the system. Also, the lowest and highest cost rates of exergy destruction belong to pump 1 and absorber, respectively. The fuel cell has the highest overall cost rate due to its high in-vestment cost.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Energy and exergy analyses of a combined cooling, heating and power system with prime mover of phosphoric acid fuel cell with organic Rankine cycle
    Chahartaghi, Mahmood
    Einanlou, Mehrdad
    Hashemian, Seyed Majid
    APPLIED THERMAL ENGINEERING, 2021, 193
  • [2] Energy, exergy, exergoeconomic, economic, and environmental analyses and multi-objective optimization of a novel combined cooling and power system with dual-pressure Kalina cycle-absorption refrigeration
    Yang, Xinle
    Yan, Zhenchao
    Bu, Shujuan
    Li, Weikang
    Yu, Ning
    Su, Chang
    Lu, Shengdong
    Wang, Xin
    Energy Conversion and Management, 2024, 315
  • [3] Energy, exergy, exergoeconomic, economic, and environmental analyses and multi-objective optimization of a novel combined cooling and power system with dual-pressure Kalina cycle-absorption refrigeration
    Yang, Xinle
    Yan, Zhenchao
    Bu, Shujuan
    Li, Weikang
    Yu, Ning
    Su, Chang
    Lu, Shengdong
    Wang, Xin
    ENERGY CONVERSION AND MANAGEMENT, 2024, 315
  • [4] Energy, exergy, exergoeconomic, and environmental (4E) analyses of a combined system comprising reformed methanol high-temperature proton exchange membrane fuel cells and absorption refrigeration cycle
    Zhong, Zhaoda
    Zhu, Jimin
    Li, Na
    Liu, Wei
    Gao, Lei
    Gao, Xin
    Araya, Samuel Simon
    Liso, Vincenzo
    Energy Sources, Part A: Recovery, Utilization and Environmental Effects, 2024, 46 (01) : 16642 - 16656
  • [5] Energy, exergy, exergoeconomic and environmental (4E) analysis of a distributed generation solar-assisted CCHP (combined cooling, heating and power) gas turbine system
    Wang, Jiangjiang
    Lu, Zherui
    Li, Meng
    Lior, Noam
    Li, Weihua
    ENERGY, 2019, 175 : 1246 - 1258
  • [6] Energy, Exergy, Exergoeconomic, and environmental (4E) analyses of thermal power plants for municipal solid waste to energy application in Bangladesh
    Adnan, Adib
    Mahmud, Shadman
    Uddin, Mohammed Raihan
    Modi, Anish
    Ehsan, M. Monjurul
    Salehin, Sayedus
    WASTE MANAGEMENT, 2021, 134 : 136 - 148
  • [7] A novel geothermal combined cooling and power cycle based on the absorption power cycle: Energy, exergy and exergoeconomic analysis
    Parikhani, Towhid
    Ghaebi, Hadi
    Rostamzadeh, Hadi
    ENERGY, 2018, 153 : 265 - 277
  • [8] Energy, exergy, exergoenvironmental, and exergoeconomic (4E) analyses of a gas boosting station
    Delshad, Mohammad Salimi
    Momenimovahed, Ali
    Mazidi, Mohammad Sh
    Ehyaei, Mehdi A.
    Rosen, Marc A.
    ENERGY SCIENCE & ENGINEERING, 2021, 9 (11) : 2044 - 2063
  • [9] Energy and Exergy Analysis of a Combined Power Generation System Using PEM Fuel Cell and Kalina Cycle System 11
    Rezaee, Vahid
    Houshmand, Arash
    PERIODICA POLYTECHNICA-CHEMICAL ENGINEERING, 2016, 60 (02) : 98 - 105
  • [10] Proposal and energy, exergy, economic, and environmental analyses of a novel combined cooling and power (CCP) system
    Fallah, Mohsen
    Sohrabi, Arvin
    Mokarram, Narges H.
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2023, 45 (09)