Comparison of monocyte distribution width and Procalcitonin as diagnostic markers for sepsis: Meta-analysis of diagnostic test accuracy studies

被引:3
|
作者
Motawea, Karam [1 ]
Rozan, Samah S. [1 ]
Talat, Nesreen Elsayed [1 ]
Elhalag, Rowan H. [1 ]
Reyad, Sarraa Mohammed [1 ]
Chebl, Pensee [1 ]
Swed, Sarya [2 ]
Sawaf, Bisher [3 ]
Alfar, Hadeel Hadeel [3 ]
Farwati, Amr [3 ]
Sabbagh, Bana [4 ]
Madera, Esperance M. [5 ]
El Metaafy, Amro [6 ]
Barboza, Joshuan J. [7 ]
Sah, Ranjit [8 ,9 ,10 ]
Aiash, Hani [11 ,12 ,13 ]
机构
[1] Alexandria Univ, Fac Med, Alexandria, Egypt
[2] Aleppo Univ, Fac Med, Aleppo, Syria
[3] Hamad Med Corp, Internal Med Dept, Doha, Qatar
[4] Al Mouwasat Univ Hosp, Dept Internal Med, Damascus, Syria
[5] Univ Med & Hlth Sci, Basseterre, St Kitts & Nevi
[6] Suez Canal Univ, Fac Med, Ismailia, Egypt
[7] Univ Cesar Vallejo, Escuela Med, Trujillo, Peru
[8] Tribhuvan Univ Teaching Hosp, Inst Med, Kathmandu, Nepal
[9] Dr DY Patil Vidyapeeth, Dr DY Patil Med Coll Hosp & Res Ctr, Dept Microbiol, Pune, Maharashtra, India
[10] D D Y Patil Vidyapeeth, D D Y Patil Dent Coll & Hosp, Dept Publ Hlth Dent, Pune, Maharashtra, India
[11] Upstate Med Univ, Dept Med, Syracuse, NY USA
[12] Upstate Med Univ, Dept Surg, Syracuse, NY USA
[13] Suez Canal Univ, Coll Med, Dept Family Med, Ismailia, Egypt
来源
PLOS ONE | 2023年 / 18卷 / 08期
关键词
DEFINITIONS; NEUTROPHILS; PREDICTION; BIOMARKERS;
D O I
10.1371/journal.pone.0288203
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
AimWe aimed to perform a meta-analysis to find out whether PCT and MDW could be used as accurate diagnostic markers for sepsis. MethodsWe searched PUBMED, WOS, and SCOPUS databases. Inclusion criteria were any observational or clinical trials that compared monocyte Distribution Width [MDW] with Procalcitonin [PCT] as diagnostic markers in a patient with sepsis. Case reports, editorials, conference abstracts, and animal studies were excluded. RevMan software [5.4] was used to perform the meta-analysis. ResultsAfter the complete screening, 5 observational studies were included in the meta-analysis. The total number of patients included in the meta-analysis in the sepsis group is 565 and 781 in the control group. The pooled analysis between the sepsis group and controls showed a statistically significant association between sepsis and increased levels of MDW and PCT [MD = 3.94, 95% CI = 2.53 to 5.36, p-value < 0.00001] and [MD = 9.29, 95% CI = 0.67 to 17.91, p-value = 0.03] respectively. Moreover, the subgroup analysis showed that the p-value of MDW levels [< 0.00001] is more significant than the p-value of PCT levels = 0.03, the p-value between the two subgroups [< 0.00001]. Additionally, the overall ROC Area for MDW [0.790] > the overall ROC Area for PCT [0.760]. ConclusionOur study revealed a statistically significant association between sepsis and increased MDW and PCT levels compared with controls and the overall ROC Area for MDW is higher than the overall ROC Area for PCT, indicating that the diagnostic accuracy of MDW is higher than PCT.MDW can be used as a diagnostic marker for sepsis patients in the emergency department. More multicenter studies are needed to support our findings.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy
    Lucas M. Fleuren
    Thomas L. T. Klausch
    Charlotte L. Zwager
    Linda J. Schoonmade
    Tingjie Guo
    Luca F. Roggeveen
    Eleonora L. Swart
    Armand R. J. Girbes
    Patrick Thoral
    Ari Ercole
    Mark Hoogendoorn
    Paul W. G. Elbers
    Intensive Care Medicine, 2020, 46 : 383 - 400
  • [42] Meta-analysis of diagnostic test accuracy in neurosurgical practice
    Dubourg, Julie
    Berhouma, Moncef
    Cotton, Michael
    Messerer, Mahmoud
    NEUROSURGICAL FOCUS, 2012, 33 (01)
  • [43] Comparative Analysis of Diagnostic Techniques for Melanoma Detection: A Systematic Review of Diagnostic Test Accuracy Studies and Meta-Analysis
    Blundo, Alessia
    Cignoni, Arianna
    Banfi, Tommaso
    Ciuti, Gastone
    FRONTIERS IN MEDICINE, 2021, 8
  • [44] Serum procalcitonin as a diagnostic marker for neonatal sepsis: a systematic review and meta-analysis
    Vouloumanou, Evridiki K.
    Plessa, Eleni
    Karageorgopoulos, Drosos E.
    Mantadakis, Elpis
    Falagas, Matthew E.
    INTENSIVE CARE MEDICINE, 2011, 37 (05) : 747 - 762
  • [45] Systematic review and meta-analysis of the diagnostic accuracy of procalcitonin for post-operative sepsis/infection in liver transplantation
    Jerome, Ellen
    Cavazza, Anna
    Menon, Krishna
    McPhail, Mark J.
    TRANSPLANT IMMUNOLOGY, 2022, 74
  • [46] Serum procalcitonin as a diagnostic marker for neonatal sepsis: a systematic review and meta-analysis
    Evridiki K. Vouloumanou
    Eleni Plessa
    Drosos E. Karageorgopoulos
    Elpis Mantadakis
    Matthew E. Falagas
    Intensive Care Medicine, 2011, 37 : 747 - 762
  • [47] A note on meta-analysis of diagnostic test studies
    Casazza, G
    ARCHIVES OF DERMATOLOGY, 2004, 140 (03) : 363 - 364
  • [48] Latent class bivariate model for the meta-analysis of diagnostic test accuracy studies
    Paolo Eusebi
    Johannes B Reitsma
    Jeroen K Vermunt
    BMC Medical Research Methodology, 14
  • [49] Latent class bivariate model for the meta-analysis of diagnostic test accuracy studies
    Eusebi, Paolo
    Reitsma, Johannes B.
    Vermunt, Jeroen K.
    BMC MEDICAL RESEARCH METHODOLOGY, 2014, 14
  • [50] Using meta-analysis to inform the design of subsequent studies of diagnostic test accuracy
    Hinchliffe, Sally R.
    Crowther, Michael J.
    Phillips, Robert S.
    Sutton, Alex J.
    RESEARCH SYNTHESIS METHODS, 2013, 4 (02) : 156 - 168