An Efficient Calibration System of Optical Interferometer for Measuring Middle and Upper Atmospheric Wind

被引:0
|
作者
Zhu, Guangyi [1 ,2 ,3 ]
Zhu, Yajun [1 ,2 ,3 ,4 ]
Kaufmann, Martin [5 ]
Wang, Tiancai [1 ,2 ,3 ]
Liu, Weijun [1 ,2 ,3 ,4 ]
Xu, Jiyao [1 ,2 ,3 ,4 ]
机构
[1] Chinese Acad Sci, Natl Space Sci Ctr, State Key Lab Space Weather, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Natl Space Sci Ctr, Key Lab Solar Act & Space Weather, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100190, Peoples R China
[4] Chinese Acad Sci, Natl Space Sci Ctr, Hainan Natl Field Sci Observat, Res Observ Space Weather, Beijing 100190, Peoples R China
[5] Inst Energy & Climate Res IEK 7, Julich Res Ctr, D-52425 Julich, Germany
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
middle and upper atmosphere; wind detection; asymmetric spatial heterodyne interferometer; doppler-shift generator; calibration; DESIGN;
D O I
10.3390/rs15071898
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Detection of the Doppler shift of airglow radiation in the middle and upper atmosphere is one of the most important methods for remote sensing of the atmospheric wind field. Laboratory and routine field calibration of an optical interferometer for wind measurement is very important. We report a novel calibration system that simulates a frequency shift of airglow emission lines introduced by wind in the middle and upper atmosphere for calibrating passive optical interferometers. The generator avoids the shortcomings of traditional motor-driven Doppler-shift generators in terms of stability and security while improving accuracy and simplifying assemblies. A simulated wind speed can be determined simultaneously using the light-beat method. The wind error simulated by the generator mainly comes from the light source, which is about 0.63 m/s. An experimental demonstration was conducted using a calibrated Fabry-Perot interferometer and showed that the root mean square of the measurement uncertainty is 0.91 m/s. The novel calibration system was applied to calibrate an asymmetric spatial heterodyne spectrometer (ASHS)-type interferometer successfully. The results demonstrate the feasibility of the system.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Parameter Optimization of Optical Sensor Calibration in Optical Coordinate Measuring System
    Li, Chengwei
    Liu, Jingliang
    Lv, Laipeng
    Zhang, Bin
    Fang, Jianguo
    PROCEEDINGS OF THE 2015 3RD INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS AND INFORMATION TECHNOLOGY APPLICATIONS, 2015, 35 : 344 - 350
  • [22] ATMOSPHERIC OPTICAL CALIBRATION SYSTEM FOR OUTDOOR TESTING OF PHOTOVOLTAIC DEVICES
    CANNON, TW
    HULSTROM, RL
    METROLOGIA, 1993, 30 (04) : 409 - 417
  • [23] Calibration of a system for measuring low air flow velocity in a wind tunnel
    Krach, Andrzej
    Kruczkowski, Janusz
    METROLOGIA, 2016, 53 (04) : 1012 - 1023
  • [24] Development of a Fizeau Interferometer System for Measuring the Profile of Large Optical Lens
    Lee, Eung-Suk
    Bae, Kwang-Hwan
    Lee, Ki-Am
    Kim, Ok-Hyun
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2006, 30 (12) : 1649 - 1657
  • [25] Calibration of laser beam direction for optical coordinate measuring system
    Chao, Bi
    Yong, Liu
    Fang Jian-guo
    Xia, Guo
    Lv Lai-peng
    Pu, Dong
    MEASUREMENT, 2015, 73 : 191 - 199
  • [26] Design and laboratory tests of a Doppler Asymmetric Spatial Heterodyne (DASH) interferometer for upper atmospheric wind and temperature observations
    Harlander, John M.
    Englert, Christoph R.
    Babcock, David D.
    Roesler, Frederick L.
    OPTICS EXPRESS, 2010, 18 (25): : 26430 - 26440
  • [27] EFFECT OF ERRORS IN THE OPTICAL-SYSTEM OF AN INTERFEROMETER ON THE ACCURACY OF MEASURING THE SHAPE OF A SURFACE
    RODIONOV, SA
    AGUROK, IP
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1988, 55 (08): : 451 - 454
  • [28] An optical scanning fiber dual-interferometer system for measuring small distance
    Li, TC
    FIBER OPTIC SENSORS V, 1996, 2895 : 58 - 63
  • [29] Exact calculation of the optical path difference and lateral displacement of modified large optical path difference Sagnac interferometer in full view field used in upper atmospheric wind field measurement
    Kai, Ruan
    Chun-Min, Zhang
    Bao-Chang, Zhao
    ACTA PHYSICA SINICA, 2008, 57 (09) : 5435 - 5441
  • [30] Exact calculation of the optical path difference and lateral displacement of modified large optical path difference Sagnac interferometer in full view field used in upper atmospheric wind field measurement
    School of Science, Xi'an Jiaotong University, Xi'an 710049, China
    不详
    不详
    Wuli Xuebao, 2008, 9 (5435-5441):