Performance investigation on novel combined power generation and refrigeration system

被引:1
|
作者
Maheswari, G. Uma [1 ]
Ganesh, N. Shankar [2 ,5 ]
Srinivas, Tangellapalli [3 ]
Reddy, Bale Viswanadha [4 ]
机构
[1] Vellore Inst Technol, Sch Informat Technol & Engn, Dept Comp Applicat, Vellore, Tamil Nadu, India
[2] Kingston Engn Coll, Dept Mech Engn, Vellore, Tamil Nadu, India
[3] Dr B R Ambedkar Natl Inst Technol, Dept Mech Engn, Jalandhar, Punjab, India
[4] Ontario Tech Univ UOIT, Fac Engn & Appl Sci, Dept Mech & Mfg Engn, Oshawa, ON, Canada
[5] Kingston Engn Coll, Dept Mech Engn, Vellore 632059, Tamil Nadu, India
关键词
Power generation; ejector refrigeration system; Kalina; exergy; relative efficiency; THERMOECONOMIC ANALYSIS; THERMODYNAMIC ANALYSIS; KALINA CYCLE; OPTIMIZATION;
D O I
10.1177/0958305X231159448
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This article aims to examine a novel combined power and refrigeration system, using renewable and waste heat sources suitable for low-temperature applications. The present system is an integrated Kalina cycle and ejector refrigeration system to generate power and refrigeration simultaneously. To improve the vapour generation, the separator vapour fraction is used as a decision variable. Relative irreversibility and efficiency defect as two important parameters considered in this system for an investigation to identify the weaker components. The combined system generates power and refrigeration with two different mediums by the incorporation of the heat exchanger at the turbine exhaust. The novel system's energy and conventional exergy evaluation are carried out through Python Software. The optimum values of decision variables: turbine concentration, separator vapour fraction, entrainment ratio, expander ratio, split ratio and turbine concentration are identified using Python software from an opted range of variables. The maximum value of net power output, first law efficiency for power generation system, combined system, second law efficiency for power generation system, combined system, refrigeration effect and coefficient of performance are obtained as 113 kW, 8.85%, 11.83%, 93.44%, 81.29%, 38.07% and 0.118, respectively, at higher separator vapour fraction. Among the components considered in the combined power generation system, the condenser and LTRGN account for the higher exergy destruction rate of 30.41% and 25.53%. The coefficient of performance is maximized at a higher value of the refrigeration effect. The turbine pressure at the inlet is increased with increments in turbine work on choosing the higher value of the expander ratio. The higher exergetic value components are not emphasized to focus on improvement.
引用
下载
收藏
页码:2935 / 2958
页数:24
相关论文
共 50 条
  • [21] Experimental studies on a combined refrigeration/power generation system activated by low-grade heat
    Han, Wei
    Chen, Qiang
    Sun, Liuli
    Ma, Sijun
    Zhao, Ting
    Zheng, Danxing
    Jin, Hongguang
    ENERGY, 2014, 74 : 59 - 66
  • [22] A novel combined power generation and argon liquefaction system; investigation and optimization of energy, exergy, and entransy phenomena
    Sari, Arif
    Abdelbasset, Walid Kamal
    Sharma, Himanshu
    Opulencia, Maria Jade Catalan
    Feyzbaxsh, Mahrad
    Abed, Azher M.
    Hussein, Shaymaa Abed
    Bashar, Bashar S.
    Hammid, Ali Thaeer
    Prakaash, A. S.
    Uktamov, Khusniddin Fakhriddinovich
    JOURNAL OF ENERGY STORAGE, 2022, 50
  • [23] Comparative performance study of an integrated air-cycle refrigeration and power generation system
    Islam, Shahid
    Dincer, Ibrahim
    APPLIED THERMAL ENGINEERING, 2016, 106 : 493 - 505
  • [24] Combined heating refrigeration and power system in food industry
    Sugiartha, N.
    Chaer, I.
    Marriott, D.
    Tassou, S. A.
    JOURNAL OF THE ENERGY INSTITUTE, 2008, 81 (04) : 185 - 190
  • [25] An investigation on the performance of solar ejector refrigeration system
    Zhang, B
    Shen, SQ
    ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 1231 - 1234
  • [26] Performance investigation on Kalina cycle with adjustable ratio based power/refrigeration cogeneration system
    Zhang S.
    Chen Y.
    Wu J.
    Zhu Z.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2019, 49 (03): : 514 - 519
  • [27] Exergy analysis of an innovative power generation and refrigeration system
    Omprakash, M.
    Ganesh, N. Shankar
    INTERNATIONAL JOURNAL OF EXERGY, 2024, 44 (02) : 160 - 171
  • [28] Thermal performance of a simplified parallel power and refrigeration combined cycle with refrigeration as the main task
    Zhang, Shaobo
    Hao, Xiaoli
    Li, Yongcun
    Yin, Wei
    APPLIED THERMAL ENGINEERING, 2022, 211
  • [29] Exergic Analysis of an ISCC System for Power Generation and Refrigeration
    Gang Wang
    Shukun Wang
    Jianqing Lin
    Zeshao Chen
    International Journal of Thermophysics, 2021, 42
  • [30] Exergic Analysis of an ISCC System for Power Generation and Refrigeration
    Wang, Gang
    Wang, Shukun
    Lin, Jianqing
    Chen, Zeshao
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2021, 42 (07)