Seismic protection of land-based wind turbine towers using the tuned inerter damper

被引:22
|
作者
Alotta, Gioacchino [1 ]
Biondo, Chiara [1 ]
Giaralis, Agathoklis [2 ,3 ,4 ]
Failla, Giuseppe [1 ]
机构
[1] Univ Reggio Calabria, Dept Civil Energy Environm & Mat Engn DICEAM, Via Graziella, I-89124 Reggio Di Calabria, Italy
[2] City Univ London, Dept Engn, London, England
[3] ABL Grp, London, England
[4] Khalifa Univ, Dept Civil Infrastruct & Environm Engn, Abu Dhabi, U Arab Emirates
关键词
Tuned inerter damper; Finite element inerter modelling; Land-based wind turbine; Seismic response mitigation; Passive vibration control; DOMAIN UNCOUPLED ANALYSES; MASS-DAMPER; VIBRATION CONTROL; MITIGATION; DESIGN; TMDI;
D O I
10.1016/j.istruc.2023.03.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The tuned inerter damper (TID) has recently emerged in the literature as a bona fide resonant vibration absorber for the seismic protection of building structures by relaxing the requirement for large secondary mass employed in conventional tuned mass dampers (TMDs). This is achieved by leveraging the inertia property of lightweight inerter devices, called inertance. This paper extends the application of the TID to address the seismic response reduction of the supporting towers of land-based wind turbines (WTs). To this aim, a novel vibration suppression strategy is proposed for WT towers in which a TID is attached at two different locations inside and along the height of the tower and is tuned to the tower's dominant natural frequency. Numerical assessment is supported by developing a finite-element model of the benchmark NREL 5 MW WT equipped with an ad hoc TID model placed at different locations in the tower and with different inertance values. The assessment includes timedomain response history analyses for 28 earthquake ground motions (GMs) with and without pulses under concurrent thrust wind forces for 4 different mean wind speeds. Improved TID vibration suppression performance is noted by installing the TID closer to the tower top and by increasing the inertance and/or the distance of the attachment locations. Further, the TID achieves significant reductions of tower top peak displacement and acceleration as well as peak base shear and bending moment for all the different combinations of GMs and wind speeds, outperforming a conventional TMD with 5% secondary mass ratio placed in the nacelle.
引用
收藏
页码:640 / 656
页数:17
相关论文
共 50 条
  • [31] Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter
    Giaralis, Agathoklis
    Petrini, Francesco
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (09)
  • [32] Land-based turbine applications
    Nava, I
    ADVANCED MATERIALS & PROCESSES, 2006, 164 (05): : 71 - +
  • [33] Response control of chimneys using tuned mass damper, multi-tuned mass damper and tuned mass inerter system
    Rahman, Saba
    Jain, A. K.
    Jha, K. N.
    Bharti, S. D.
    Datta, T. K.
    STRUCTURES, 2024, 69
  • [34] Tandem tuned mass damper inerter for passive control of buildings under seismic loads
    Farzam, Maziar Fahimi
    Jalali, Himan Hojat
    STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (09):
  • [35] Innovative rail transport of a supersized land-based wind turbine blade
    Carron, William Scott
    Bortolotti, Pietro
    SCIENCE OF MAKING TORQUE FROM WIND (TORQUE 2020), PTS 1-5, 2020, 1618
  • [36] Performance evaluation of a lever-assisted optimized tuned mass damper inerter in mitigating edgewise vibration of wind turbine blade
    Sonkusare, Vishal D.
    Bera, Kamal Krishna
    ENGINEERING STRUCTURES, 2025, 331
  • [37] Optimized Design of a Tuned Mass Damper Inerter (TMDI) Applied to Circular Section Members of Transmission Towers
    Bian, Yongfei
    Liu, Xinpeng
    Sun, Yi
    Zhong, Yongli
    BUILDINGS, 2022, 12 (08)
  • [38] Fluid inerter for optimal vibration control of floating offshore wind turbine towers
    Sarkar S.
    Fitzgerald B.
    Engineering Structures, 2022, 266
  • [39] Dual-Demand-Based Optimal Design of Grounded Tuned Mass Damper Inerter for Seismic Response Mitigation
    Zhang, Ruoyu
    Huang, Jizhong
    Zhang, Yue
    JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2024, 12 (02) : 1429 - 1443
  • [40] Dual-Demand-Based Optimal Design of Grounded Tuned Mass Damper Inerter for Seismic Response Mitigation
    Ruoyu Zhang
    Jizhong Huang
    Yue Zhang
    Journal of Vibration Engineering & Technologies, 2024, 12 : 1429 - 1443