Seismic protection of land-based wind turbine towers using the tuned inerter damper

被引:22
|
作者
Alotta, Gioacchino [1 ]
Biondo, Chiara [1 ]
Giaralis, Agathoklis [2 ,3 ,4 ]
Failla, Giuseppe [1 ]
机构
[1] Univ Reggio Calabria, Dept Civil Energy Environm & Mat Engn DICEAM, Via Graziella, I-89124 Reggio Di Calabria, Italy
[2] City Univ London, Dept Engn, London, England
[3] ABL Grp, London, England
[4] Khalifa Univ, Dept Civil Infrastruct & Environm Engn, Abu Dhabi, U Arab Emirates
关键词
Tuned inerter damper; Finite element inerter modelling; Land-based wind turbine; Seismic response mitigation; Passive vibration control; DOMAIN UNCOUPLED ANALYSES; MASS-DAMPER; VIBRATION CONTROL; MITIGATION; DESIGN; TMDI;
D O I
10.1016/j.istruc.2023.03.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The tuned inerter damper (TID) has recently emerged in the literature as a bona fide resonant vibration absorber for the seismic protection of building structures by relaxing the requirement for large secondary mass employed in conventional tuned mass dampers (TMDs). This is achieved by leveraging the inertia property of lightweight inerter devices, called inertance. This paper extends the application of the TID to address the seismic response reduction of the supporting towers of land-based wind turbines (WTs). To this aim, a novel vibration suppression strategy is proposed for WT towers in which a TID is attached at two different locations inside and along the height of the tower and is tuned to the tower's dominant natural frequency. Numerical assessment is supported by developing a finite-element model of the benchmark NREL 5 MW WT equipped with an ad hoc TID model placed at different locations in the tower and with different inertance values. The assessment includes timedomain response history analyses for 28 earthquake ground motions (GMs) with and without pulses under concurrent thrust wind forces for 4 different mean wind speeds. Improved TID vibration suppression performance is noted by installing the TID closer to the tower top and by increasing the inertance and/or the distance of the attachment locations. Further, the TID achieves significant reductions of tower top peak displacement and acceleration as well as peak base shear and bending moment for all the different combinations of GMs and wind speeds, outperforming a conventional TMD with 5% secondary mass ratio placed in the nacelle.
引用
收藏
页码:640 / 656
页数:17
相关论文
共 50 条
  • [1] Vibration control of spar-type floating offshore wind turbine towers using a tuned mass-damper-inerter
    Sarkar, Saptarshi
    Fitzgerald, Breiffni
    STRUCTURAL CONTROL & HEALTH MONITORING, 2020, 27 (01):
  • [2] A cable-based tuned inerter damper for edgewise vibration control of the wind turbine blade
    Tang, Jiawei
    Cai, Qinlin
    Dai, Kaoshan
    Liu, Yangzhao
    Heng, Junling
    Luo, Yuxiao
    ENGINEERING STRUCTURES, 2025, 323
  • [3] Seismic response mitigation of a wind turbine tower using a tuned parallel inerter mass system
    Zhang, Ruifu
    Zhao, Zhipeng
    Dai, Kaoshann
    ENGINEERING STRUCTURES, 2019, 180 : 29 - 39
  • [4] Tuned mass-damper-inerter (TMDI) for suppressing edgewise vibrations of wind turbine blades
    Zhang, Zili
    Fitzgerald, Breiffni
    ENGINEERING STRUCTURES, 2020, 221
  • [5] Seismic Control of Story Isolation System Using Tuned Mass Damper Inerter
    Liang, Qigang
    Wei, Jinyuan
    Li, Luyu
    JOURNAL OF ENGINEERING MECHANICS, 2023, 149 (03)
  • [6] The nonlinear behavior of prestressed tuned mass damper for vibration control of wind turbine towers
    Gang Liu
    Zhenbo Lei
    S. S. Law
    Qingshan Yang
    Nonlinear Dynamics, 2023, 111 : 10939 - 10955
  • [7] The nonlinear behavior of prestressed tuned mass damper for vibration control of wind turbine towers
    Liu, Gang
    Lei, Zhenbo
    Law, S. S.
    Yang, Qingshan
    NONLINEAR DYNAMICS, 2023, 111 (12) : 10939 - 10955
  • [8] Parameters Optimization and Performance Evaluation of the Tuned Inerter Damper for the Seismic Protection of Adjacent Building Structures
    Kang, Xiaofang
    Wu, Jian
    Wang, Xinqi
    Lei, Shancheng
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2024, 138 (01): : 551 - 593
  • [9] Statistical seismic performance assessment of tuned mass damper inerter
    Kaveh, Ali
    Farzam, Maziar Fahimi
    Jalali, Himan Hojat
    STRUCTURAL CONTROL & HEALTH MONITORING, 2020, 27 (10):
  • [10] The Seismic Mitigation Design of Tuned Inerter Damper for Building Structure
    Liu L.
    Tan P.
    Yan W.
    Zhou F.
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2018, 38 (04): : 751 - 757