Ex Vivo Comparison of the Diagnostic Performance of Two-Dimensional and Three-Dimensional Three-Tesla Magnetic Resonance Imaging Sequences in Depicting Normal Articular Cartilage in Equine Stifle Cadavers

被引:0
|
作者
Seidler, Annika [1 ]
Assmann, Anton [1 ]
Torgerson, Paul R. [2 ]
Sanchez-Andrade, Jose Suarez [3 ]
Bischofberger, Andrea [3 ]
机构
[1] Univ Zurich, Equine Hosp, Vetsuisse Fac, CH-8057 Zurich, Switzerland
[2] Univ Zurich, Vetsuisse Fac, Sect Vet Epidemiol, CH-8057 Zurich, Switzerland
[3] Univ Zurich, Equine Hosp, Clin Diagnost Imaging, Vetsuisse Fac, CH-8057 Zurich, Switzerland
来源
ANIMALS | 2024年 / 14卷 / 01期
关键词
horse; stifle joint; MRI; 2D sequences; 3D sequences; articular cartilage; COMPUTED TOMOGRAPHIC ARTHROGRAPHY; THICKNESS MEASUREMENTS; VALIDATION; MRI; VOLUME;
D O I
10.3390/ani14010015
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
The objective of this study was to compare articular cartilage thickness observed in the different 2D and 3D sequences to the cartilage thickness of the equine stifle in cadavers to determine the accuracy of each sequence. The study was conducted as a blinded laboratory study using seven equine stifle specimens. The 2D (T2W TSE) and 3D (3D VIEW T2W HR, T2 3D mFFE, T1W VISTA SPAIR, 3D PDW SPAIR) 3-tesla MRI sequences of each stifle were obtained. Cartilage thickness was measured at 30 locations on MRI and on gross pathology. Thickness measurements were compared using a Bland-Altman plot and post hoc analysis tests. The 3D sequences were found to be generally more accurate than the 2D sequence (p < 0.001). The smallest difference to macroscopic measurements was observed in the 3D VIEW T2W HR and T1W VISTA SPAIR sequences with no statistical difference between each other. Knowing the accuracy of different sequences will improve the evaluation of equine cartilage and the early detection of cartilage pathologies. This would promote MRI as a noninvasive imaging modality for horses suffering from stifle lameness with no findings in conventional imaging methods. Furthermore, since 3D sequences seem to have better accuracy in depicting cartilage, they may replace 2D sequences, thereby shortening scanning times.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] COMPARISON OF TRANSTHORACIC TWO-DIMENSIONAL ECHOCARDIOGRAPHY, THREE-DIMENSIONAL ECHOCARDIOGRAPHY, TRANSESOPHAGEAL ECHOCARDIOGRAPHY, COMPUTED TOMOGRAPHY ANGIOGRAPHY, AND GATED MAGNETIC RESONANCE IMAGING IN NORMAL CANINE HEARTS.
    Fries, R. C.
    Gordon, S. G.
    Miller, M. W.
    Saunders, A. B.
    Hariu, C. D.
    Bogess, M.
    Lennox, M.
    Fossum, T. W.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2012, 26 (03) : 710 - 710
  • [22] Comparison of diagnostic accuracy of three-dimensional transvaginal ultrasound and magnetic resonance imaging in the diagnosis of scar pregnancy
    Huang, Zhulan
    Liu, Jinghua
    Jing, Zongyu
    Lin, Limei
    Li, Xiaoyun
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2022, 38 (07) : 1743 - 1747
  • [23] Agreement of two-dimensional and three-dimensional transvaginal ultrasound with magnetic resonance imaging in assessment of parametrial infiltration in cervical cancer
    Chiappa, V.
    Di Legge, A.
    Valentini, A. L.
    Gui, B.
    Micco, M.
    Ludovisi, M.
    Giansiracusa, C.
    Testa, A. C.
    Valentin, L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 45 (04) : 459 - 469
  • [24] Monitoring of lung motion in patients with malignant pleural mesothelioma using two-dimensional and three-dimensional dynamic magnetic resonance imaging - Comparison with spirometry
    Plathow, C
    Klopp, M
    Schoebinger, M
    Thieke, C
    Fink, C
    Puderbach, M
    Ley, S
    Weber, MA
    Sandner, A
    Claussen, CD
    Herth, F
    Tuengerthal, S
    Meinzer, HP
    Kauczor, HU
    INVESTIGATIVE RADIOLOGY, 2006, 41 (05) : 443 - 448
  • [25] Value of real-time three-dimensional echocardiography in patients with hypertrophic cardiomyopathy. Comparison with two-dimensional echocardiography and magnetic resonance imaging
    Bicudo, L.
    Tsutsui, J.
    Shiozaki, A.
    Rochitte, C.
    Arteaga, E.
    Mady, C.
    Mathias, W.
    CIRCULATION, 2008, 118 (12) : E421 - E421
  • [26] Comparison of two-dimensional and multi-slab three-dimensional magnetic resonance techniques for measuring carotid wall volumes
    Keenan, N. G.
    Grasso, A.
    Locca, D.
    Roughton, M.
    Gatehouse, P. D.
    Firmin, D. N.
    Pennell, D. J.
    HEART, 2008, 94 : A78 - A78
  • [27] Three-Dimensional Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) Score Assessed With an Isotropic Three-Dimensional True Fast Imaging With Steady-State Precession Sequence at 3.0 Tesla
    Welsch, Goetz H.
    Zak, Lukas
    Mamisch, Tallal C.
    Resinger, Christoph
    Marlovits, Stefan
    Trattnig, Siegfried
    INVESTIGATIVE RADIOLOGY, 2009, 44 (09) : 603 - 612
  • [28] Assessment of mechanical properties of articular cartilage with quantitative three-dimensional ultrashort echo time (UTE) cones magnetic resonance imaging
    Namiranian, Behnam
    Jerban, Saeed
    Ma, Yajun
    Dorthe, Erik W.
    Masoud-Afsahi, Amir
    Wong, Jonathan
    Wei, Zhao
    Chen, Yanjun
    D'Lima, Darryl
    Chang, Eric Y.
    Du, Jiang
    JOURNAL OF BIOMECHANICS, 2020, 113
  • [29] Significance of three-dimensional turbo spin-echo magnetic resonance imaging with semiquantitative assessment of knee osteoarthritis: correlation to two-dimensional routine magnetic resonance imaging
    Hashem, Aya Mohamed Bassam
    El-Liethy, Nevien Ezzat Mohamed
    El-Din, Osama Mohamed Helmy Noor
    Mahmoud, Mostafa Ezzat
    Hashem, Lamiaa Mohamed Bassam
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):
  • [30] Three-dimensional turbo spin-echo magnetic resonance imaging (MRI) and semiquantitative assessment of knee osteoarthritis: comparison with two-dimensional routine MRI
    Crema, M. D.
    Nogueira-Barbosa, M. H.
    Roemer, F. W.
    Marra, M. D.
    Niu, J.
    Chagas-Neto, F. A.
    Gregio-Junior, E.
    Guermazi, A.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (03) : 428 - 433