Integrating FBN and FDS for quantitative risk assessment of cable fire in utility tunnel

被引:13
|
作者
Zhu, Xiaoping [1 ]
Wu, Jiansong [1 ]
Bai, Yiping [1 ]
Wang, Dong [2 ]
Zhang, Jun [3 ]
机构
[1] China Univ Min & Technol Beijing, Sch Emergency Management & Safety Engn, Beijing 100083, Peoples R China
[2] State Grid Corp China, Beijing 100031, Peoples R China
[3] State Grid Energy Res Inst Co Ltd, Beijing 102209, Peoples R China
基金
中国国家自然科学基金;
关键词
Utility tunnel; Cable fire; Risk assessment; Fuzzy bayesian network (FBN); Fire dynamic simulator (FDS); Safety barrier; SAFETY ASSESSMENT; STATIONS;
D O I
10.1016/j.jlp.2024.105266
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The highly integrated underground utility tunnel (UUT) is a kind of critical infrastructure for process clusters and cities. However, this integration inevitably entails potential risks, including gas leakage, explosions, cable fires, and the accumulation of toxic gases within sewage pipes, and the concern regarding cable fires supersedes others due to their multifactorial correlations and severe consequences. Especially in utility tunnels within chemical industrial parks, cable fires can precipitate the shutdown of equipment, potentially culminating in grave incidents such as chemical leaks or uncontrolled reactions, owing to failures in control systems. This paper presents a novel dynamic risk assessment model for cable compartment fire in UUTs, integrating the Fuzzy Bayesian Network (FBN), Fire Dynamic Simulator (FDS). By employing sensitivity analysis and vulnerability path analysis techniques within the FBN framework, critical hazards associated with cable compartment fires are identified. Subsequently, a comprehensive FDS analysis is conducted for a standardized UUT cable compartment fire consequence, considering the chain response of the safety barriers. The obtained results reveal that even with normal safety barrier response, the risk in the early stage of a fire cannot be disregarded. Notably, among various safety barrier failure scenarios, the failure of a single fire door has the lowest integrated risk, while sensor failure may lead to a higher peak of integrated risk, as well as a higher average integrated risk due to sprinkler failure. The results indicate that the proposed model can offer practical supports in accident mitigation, risk management, and safety barrier optimization of cable compartments in UUTs.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Experimental study on fire performance of optical cables used in utility tunnel: Influence of cable spacing and heat flux
    An, Weiguang
    Sun, Xiaoxiao
    Tang, Yanhua
    Wang, Tao
    Wang, Zhe
    FIRE AND MATERIALS, 2023, 47 (07) : 884 - 891
  • [32] DSS for risk assessment of transportation of dangerous goods integrating tunnel fires assessment and simulation
    Gheorghe, AV
    Hoj, NP
    Vamanu, D
    Kröger, W
    PSAM 5: PROBABILISTIC SAFETY ASSESSMENT AND MANAGEMENT, VOLS 1-4, 2000, (34): : 2213 - 2220
  • [33] Bayesian assessment of utility tunnel risk based on information sharing mechanism
    Zhang, Guodong
    Shi, Meixia
    JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2021, 41 (04) : 4749 - 4757
  • [34] Study on Quantitative Risk Assessment of LGP Transportation in Road Tunnel
    Zhang, Yuchun
    He, Chuan
    Fang, Yong
    Sun, Xiaoqin
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 4105 - +
  • [35] Revised fire consequence models for offshore quantitative risk assessment
    Pula, R
    Khan, FI
    Veitch, B
    Amyotte, PR
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2005, 18 (4-6) : 443 - 454
  • [36] Research on the Fire Extinguishing Efficiency of Low-Pressure Water Mist in Urban Underground Utility Tunnel Cable Fires
    Jia, Boyan
    Xia, Yanwei
    Ning, Zhaoyu
    Li, Bin
    Zhang, Guowei
    Zhang, Zhiwei
    FIRE-SWITZERLAND, 2023, 6 (11):
  • [37] Introduction to quantitative AOP models and their utility in toxicology and risk assessment
    Luijten, M.
    TOXICOLOGY LETTERS, 2023, 384 : S48 - S48
  • [38] Probabilistic Assessment of Domino Effect Triggered by Fire: Implementation in Quantitative Risk Assessment
    Landuccr, Gabriele
    Antonioni, Giacomo
    Tugnoli, Alessandro
    Cozzani, Valerio
    CISAP5: INTERNATIONAL CONFERENCE ON SAFETY & ENVIRONMENT IN PROCESS & POWER INDUSTRY, PT 1, 2012, 26 : 195 - 200
  • [39] Risk and Energy Based Optimization for Fire Monitoring System in Utility Tunnel Using Cellular Automata
    Zhang, Ying
    Bai, Jitao
    Diao, Yu
    Chen, Zhonghao
    Wang, Chu
    Yang, Kun
    Gao, Zeng
    Wei, Huajie
    SUSTAINABILITY, 2024, 16 (11)
  • [40] Integrating Fire Behavior Models and Geospatial Analysis for Wildland Fire Risk Assessment and Fuel Management Planning
    Ager, Alan A.
    Vaillant, Nicole M.
    Finney, Mark A.
    JOURNAL OF COMBUSTION, 2011, 2011