Comparison of Mechanical Forces used in Open Tracheotomy versus Percutaneous Tracheotomy Techniques

被引:0
|
作者
Bharathi, Ramya [1 ,5 ]
Rao, Gopikrishna M. [2 ]
Tracy, Jeremiah [1 ,2 ]
Groblewski, Jan [3 ,4 ]
Koenigs, Maria [3 ,4 ]
机构
[1] Tufts Med Ctr, Dept Otolaryngol, Boston, MA USA
[2] Tufts Univ, Sch Med, Boston, MA USA
[3] Hasbro Childrens Hosp, Dept Otolaryngol, Providence, RI USA
[4] Brown Univ, Warren Alpert Med Sch, Providence, RI USA
[5] Tufts Med Ctr, Dept Otolaryngol, 800 Washington St Box 850, Boston, MA 02111 USA
来源
LARYNGOSCOPE | 2024年 / 134卷 / 01期
关键词
complication; mechanical force; open tracheostomy; percutaneous tracheostomy; tracheal injury; SURGICAL TRACHEOSTOMY; TRACHEAL STENOSIS;
D O I
10.1002/lary.30786
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To understand the etiology of tracheotomy-induced tracheal stenosis by comparing the differences in techniques and mechanical force applied with open tracheotomy (OT) versus percutaneous tracheotomy (PCT) placement.Methods: This study is an unblinded, experimental, randomized controlled study in an ex-vivo animal model. Simulated tracheostomies were performed on 10 porcine tracheas, 5 via a tracheal window technique (OT) and 5 using the Ciaglia technique (PCT). The applied weight during the simulated tracheostomy and the compression of the trachea were recorded at set times during the procedure. The applied weight during tracheostomy was used to calculate the tissue force in Newtons. Tracheal compression was measured by anterior-posterior distance compression and as percent change.Results: Average forces for scalpel (OT) versus trocar (PCT) were 2.6 N and 12.5 N (p < 0.01), with the dilator (PCT) it was 22.02 N (p < 0.01). The tracheostomy placement with OT required an average force of 10.7 N versus 23.2 N (p < 0.01) with PCT. The average change in AP distance when using the scalpel versus trocar was 21%, and 44% (p < 0.01), with the dilator it was 75% (p < 0.01). The trach placement with OT versus PCT had an average AP distance change of 51% and 83% respectively (p < 0.01).Conclusion: This study demonstrated that PCT required more force and caused more tracheal lumen compression when compared to the OT technique. Based on the increased force required for PCT, we suspect there could also be an increased risk for tracheal cartilage trauma.
引用
收藏
页码:103 / 107
页数:5
相关论文
共 50 条
  • [31] Comparison of open versus percutaneous treatment for humeral head fracture
    Kralinger, F.
    Irenberger, A.
    Lechner, C.
    Wambacher, M.
    Golser, K.
    Sperner, G.
    UNFALLCHIRURG, 2006, 109 (05): : 406 - 410
  • [32] PERCUTANEOUS TRANSVENOUS MITRAL COMMISSUROTOMY - A COMPARISON TO THE CLOSED AND OPEN SURGICAL TECHNIQUES
    DEAN, LS
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, : 76 - 81
  • [33] Superior articulating facet violation: percutaneous versus open techniques Clinical article
    Jones-Quaidoo, Sean M.
    Djurasovic, Mladen
    Owens, R. Kirk, II
    Carreon, Leah Y.
    JOURNAL OF NEUROSURGERY-SPINE, 2013, 18 (06) : 593 - 597
  • [34] Percutaneous versus Open Tracheostomy: Comparison of Procedures and Surgical Site Infections
    Park, Habeeba
    Kent, Jennifer
    Joshi, Manjari
    Zhu, Shijun
    Bochicchio, Grant V.
    Henry, Sharon
    Scalea, Thomas
    SURGICAL INFECTIONS, 2013, 14 (01) : 21 - 23
  • [35] Spinopelvic Dissociation: Comparison of Outcomes of Percutaneous versus Open Fixation Strategies
    Pearson, Jeffrey M.
    Niemeier, Thomas E.
    McGwin, Gerald
    Manoharan, Sakthivel Rajaram
    ADVANCES IN ORTHOPEDICS, 2018, 2018
  • [36] Comparison of open versus percutaneous pedicle screw insertion in a sheep model
    Lehmann, W.
    Ushmaev, A.
    Ruecker, A.
    Nuechtern, J.
    Grossterlinden, L.
    Begemann, P. G.
    Baeumer, T.
    Rueger, J. M.
    Briem, D.
    EUROPEAN SPINE JOURNAL, 2008, 17 (06) : 857 - 863
  • [37] A BIOMECHANICAL INVITRO COMPARISON OF OPEN VERSUS PERCUTANEOUS REPAIR OF TENDON ACHILLES
    HOCKENBURY, RT
    JOHNS, JC
    FOOT & ANKLE, 1990, 11 (02): : 67 - 72
  • [38] Comparison of open versus percutaneous pedicle screw insertion in a sheep model
    W. Lehmann
    A. Ushmaev
    A. Ruecker
    J. Nuechtern
    L. Grossterlinden
    P. G. Begemann
    T. Baeumer
    J. M. Rueger
    D. Briem
    European Spine Journal, 2008, 17 : 857 - 863
  • [39] Surgical treatment of thoracolumbar fracture in ankylosing spondylitis: A comparison of percutaneous and open techniques
    JingYao Ye
    Ping Jiang
    HuaPeng Guan
    ChuanFu Wei
    Sen Li
    MengLong Jia
    NianHu Li
    Journal of Orthopaedic Surgery and Research, 17
  • [40] A comparison of two techniques: Open and percutaneous biopsies of thoracolumbar vertebral body lesions
    Yapici, Furkan
    Atici, Yunus
    Balioglu, Mehmet Bulent
    Albayrak, Akif
    Kargin, Deniz
    Akman, Yunus Emre
    Erdogan, Sinan
    Kaygusuz, Mehmet Akif
    JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2015, 6 (01): : 36 - 39