Nanoscale X-ray Tomography of Integrated Circuits using a Hybrid Electron/X-ray Microscope: Results and Prospects

被引:0
|
作者
Nakamura, Nathan [1 ]
Szypryt, Paul [1 ]
Fowler, Joseph W. [1 ]
Levine, Zachary H. [2 ]
Swetz, Daniel S. [3 ]
机构
[1] Univ Colorado, Dept Phys, Boulder, CO 80309 USA
[2] NIST, Quantum Opt Grp, Gaithersburg, MD 20899 USA
[3] Natl Inst Stand & Technol, Quantum Sensors Grp, Boulder, CO USA
关键词
Integrated circuits; x-ray computed tomography; nanoscale imaging;
D O I
10.1109/PAINE58317.2023.10318004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Accurate characterization of subsurface features in integrated circuits (ICs) is essential for defect detection, quality assurance, and supply chain security. The interiors of ICs are challenging to probe post-manufacturing due to the presence of many close-packed and nanoscale subsurface features of multiple material compositions, often spread over square millimeters of chip area. X-ray computed tomography (CT) has historically been a powerful tool for 3-dimensional imaging of buried features, but modern instruments are unable to achieve the spatial resolution, elemental sensitivity, or scan areas required to fully characterize ICs. Advanced imaging of ICs is possible at synchrotron beamlines, but such methods are not easily accessible and could not reside directly at a semiconductor foundry or security agency. A need exists for compact, laboratory-scale instrumentation that can image nanoscale features in 3-dimensions over large areas, with sensitivity to feature size, shape, and composition. We describe an approach to x-ray CT which merges a focused electron beam with high magnification system geometry and a combination of high efficiency and high resolving power x-ray detection. This achieves nanoscale, element-sensitive imaging of ICs in a compact instrument footprint. A proof-of-concept has been demonstrated and current imaging capabilities are discussed. The path forward is described, with opportunity for advances in spatial resolution, imaging speed, and spectral imaging capabilities beyond conventional laboratory CT instruments.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 50 条
  • [21] Electron microscope gets x-ray vision
    Feder, Toni
    PHYSICS TODAY, 2011, 64 (10) : 28 - 29
  • [22] A SCANNING ELECTRON MICROSCOPE AND X-RAY MICROANALYZER
    FETISOV, DV
    KUSHNIR, YM
    DITSMAN, SA
    DERSHVAR.GV
    POSTNIKO.EB
    POCHTARE.BI
    RASPLETI.KK
    YURCHENK.GY
    BEZLEPKI.SV
    SAMOILOV, AI
    STEPANOV, SS
    GUROVA, RP
    SPEKTOR, FU
    PARSHINA, OK
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1968, 32 (06): : 942 - &
  • [23] X-RAY SHADOW MICROSCOPY WITH AN ELECTRON MICROSCOPE
    MORITO, N
    KOMODA, T
    JOURNAL OF APPLIED PHYSICS, 1957, 28 (11) : 1380 - 1380
  • [24] Development of Scanning Electron and X-ray Microscope
    Matsumura, Tomokazu
    Hirano, Tomohiko
    Suyama, Motohiro
    XRM 2014: PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2016, 1696
  • [25] UNIVERSAL X-RAY ADAPTOR FOR ELECTRON MICROSCOPE
    LIDER, VV
    ROZHANSKII, VN
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1970, 34 (07): : 1447 - +
  • [26] AN X-RAY AND ELECTRON MICROSCOPE STUDY OF TROPOMYOSIN
    ASTBURY, WT
    REED, R
    SPARK, LC
    BIOCHEMICAL JOURNAL, 1948, 43 (02) : 282 - &
  • [27] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [29] Soft X-ray microscopy with a cryo scanning transmission X-ray microscope: II. Tomography
    Wang, Y
    Jacobsen, C
    Maser, J
    Osanna, A
    JOURNAL OF MICROSCOPY-OXFORD, 2000, 197 : 80 - 93
  • [30] X-RAY OPTICS Highly efficient nanoscale X-ray sources
    Rolles, Daniel
    NATURE PHOTONICS, 2018, 12 (02) : 62 - 63