Cerebral Embolic Protection during Transcatheter Aortic Valve Implantation: Updated Systematic Review and Meta-Analysis

被引:8
|
作者
Zahid, Salman [1 ]
Ullah, Waqas [2 ]
Khan, Muhammad Zia [3 ]
Uddin, Muhammad Faisal [1 ]
Rai, Devesh [1 ]
Abbas, Sakina [4 ]
Khan, Muhammad Usman [2 ]
Hussein, Ahmed [1 ]
Salama, Amr [1 ]
Bandyopadhyay, Dhrubajyoti [5 ]
Baibhav, Bipul [1 ]
Rao, Mohan [1 ]
Alam, Mahboob [6 ]
Alraies, M. Chadi [7 ]
Balla, Sudarshan [3 ]
Alkhouli, Mohamad [8 ]
Depta, Jeremiah P. [1 ]
机构
[1] Rochester Gen Hosp, Sands Constellat Heart Inst, Rochester, NY 14621 USA
[2] Thomas Jefferson Univ Hosp, Dept Cardiovasc Med, Philadelphia, PA USA
[3] West Virginia Univ, Heart & Vasc Inst, Div Cardiovasc Med, Morgantown, WV USA
[4] Dow Med Coll, Dept Med, Karachi, Pakistan
[5] New York Med Coll, Divi s Cardiovasc Med, Westchester Med Ctr, New York, NY USA
[6] Baylor Coll Med, Div Cardiol, Houston, TX USA
[7] Detroit Med Ctr, Div Cardiol, Detroit, MI USA
[8] Mayo Clin, Div Intervent Cardiol, Rochester, MN USA
关键词
REPLACEMENT; RISK; DEVICES; STROKE; SILENT; BRAIN; TAVI;
D O I
10.1016/j.cpcardiol.2022.101127
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In patient undergoing transcatheter aortic valve implantation (TAVI), stroke remains a poten-tially devastating complication associated with signifi-cant morbidity, and mortality. To reduce the risk of stroke, cerebral protection devices (CPD) were devel-oped to prevent debris from embolizing to the brain during TAVI. We performed a systematic review and meta-analysis to determine the safety and efficacy of CPD in TAVI. The MEDLINE (PubMed, Ovid) and Cochrane databases were queried with various combi-nations of medical subject headings to identify relevant articles. Statistical analysis was performed using a random-effects model to calculate unadjusted odds ratio (OR), including subgroup analyses based on fol-low-up duration, study design, and type of CPD. Using a pooled analysis, CPD was associated with a signifi-cant reduction in major adverse cardiovascular events MACE (OR 0.75, 95% CI 0.70-0.81, P < 0.01), mortal-ity (OR 0.65, 95% CI 0.58-0.74, P < 0.01) and stroke (OR 0.84, 95% CI 0.76-0.93, P < 0.01) in patients undergoing TAVI. Similarly, on MRI volume per lesion were lower for patients with CPD use. No signifi-cant difference was observed in acute kidney injury (OR 0.75, 95% CI 0.42-1.37, P = 0.68), bleeding (OR 0.92, 95% CI 0.71-1.20, P = 0.55) or vascular complica-tions (OR 0.90, 95% CI 0.62-1.31, P = 0.6) for patients undergoing TAVI with CPD. In conclusion, CPD device use in TAVI is associated with a reduction of MACE, mortality, and stroke compared with patients undergoing TAVI without CPD. However, the signifi-cant reduction in mortality is driven mainly by obser-vational studies. (Curr Probl Cardiol 2023;48:101127.)
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Neurological outcomes of transcatheter aortic valve implantation with or without cerebral embolic protection devices: A meta-analysis
    Perez-Camargo, Daniel
    Travieso, Alejandro
    Carnero-Alcazar, Manuel
    Taramasso, Maurizio
    Cobiella-Carnicer, Javier
    Maroto-Castellanos, Luis C.
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2022, 31 (09):
  • [22] Cerebral Embolic Protection Device protects against stroke during Transcatheter Aortic Valve Replacement (TAVR): An Updated Meta-Analysis
    Basit, J.
    Fatima, M.
    Zaheer, Z.
    Rehman, M. Ebad Ur
    Ahmed, N.
    Lee, Q.
    Saeed, S.
    Leung, C.
    Maqbool, S.
    Malik, J.
    Tse, G.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [23] Role of Cerebral Embolic Protection Devices in Patients Undergoing Transcatheter Aortic Valve Replacement: An Updated Meta-Analysis
    Kaur, Arpanjeet
    Dhaliwal, Arshdeep S.
    Sohal, Sumit
    Gwon, Yeongjin
    Gupta, Soumya
    Bhatia, Kirtipal
    Dominguez, Abel Casso
    Basman, Craig
    Tamis-Holland, Jacqueline
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2024, 13 (03):
  • [24] Efficacy and Safety of Cerebral Embolic Protection Devices in Transcatheter Aortic-Valve Replacement: An Updated Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Elfaituri, Muhammed K.
    Khaled, Taha
    BenGhatnsh, Ahmed
    Faraj, Hazem Abdelkarem A.
    Msherghi, Ahmed
    CIRCULATION, 2023, 148
  • [25] Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis
    Sehatbakhsh, Samineh
    Kushnir, Alexander
    Chait, Robert
    Lovitz, Lawrence
    Donath, Elie
    Rothenberg, Mark
    Midwall, Scott
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B682 - B682
  • [26] Routine Cerebral Embolic Protection during Transcatheter Aortic-Valve Implantation
    Kharbanda, Rajesh K.
    Kennedy, James
    Jamal, Zahra
    Dodd, Matthew
    Evans, Richard
    Bal, Kiran K.
    Perkins, Alexander D.
    Blackman, Daniel J.
    Hildick-Smith, David
    Banning, Adrian P.
    Baumbach, Andreas
    Ludman, Peter
    Palmer, Stephen
    Stables, Rodney H.
    Henderson, Robert
    Appleby, Clare
    Cotton, James
    Curzen, Nick
    Ozkor, Muhiddin
    Byrne, Jonathan
    Aggarwal, Rajesh
    Das, Rajiv
    Doshi, Sagar
    Watkins, Stuart
    Muir, Douglas F.
    Anderson, Richard
    Chowdhary, Saqib
    Varcoe, Richard
    Dorman, Stephen
    Firoozi, Sam
    Chelliah, Raj
    Owens, Colum
    Redwood, Simon
    Prendergast, Bernard
    Iqbal, Javaid
    Ratib, Karim
    Dospinescu, Ciprian
    Suresh, Venkatesan
    Cruden, Nicholas
    Rajathurai, Thirumaran
    Malik, Iqbal S.
    Wiper, Andrew
    Costopoulos, Charis
    Khurana, Ayush
    Banning, Amerjeet
    Clayton, Tim
    NEW ENGLAND JOURNAL OF MEDICINE, 2025,
  • [27] Reduction in Stroke Rates With Embolic Protection Device During Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis
    Thakkar, Samarthkumar J.
    Kumar, Ashish
    Shah, Jay
    Gullapalli, Nageshwara
    Meraj, Perwaiz M.
    Doshi, Rajkumar P.
    CIRCULATION, 2019, 140
  • [28] Safety and efficacy of cerebral embolic protection devices for patients undergoing transcatheter aortic valve replacement: An updated meta-analysis
    Shrestha, Dhan Bahadur
    Shtembari, Jurgen
    Lamichhane, Sandesh
    Baniya, Abinash
    Shahi, Manoj
    Dhungel, Swati
    Pant, Kailash
    Sutton, Nadia R.
    Villablanca, Pedro
    Mungee, Sudhir
    HEALTH SCIENCE REPORTS, 2023, 6 (07)
  • [29] Cerebral embolic protection during transcatheter aortic valve replacement: a systematic review and meta-analysis of propensity score matched and randomized controlled trials using the Sentinel cerebral embolic protection device
    Wolfrum, Mathias
    Handerer, Immanuel Justus
    Moccetti, Federico
    Schmeisser, Alexander
    Braun-Dullaeus, Ruediger C.
    Toggweiler, Stefan
    BMC CARDIOVASCULAR DISORDERS, 2023, 23 (01)
  • [30] Cerebral embolic protection during transcatheter aortic valve replacement: a systematic review and meta-analysis of propensity score matched and randomized controlled trials using the Sentinel cerebral embolic protection device
    Mathias Wolfrum
    Immanuel Justus Handerer
    Federico Moccetti
    Alexander Schmeisser
    Ruediger C. Braun-Dullaeus
    Stefan Toggweiler
    BMC Cardiovascular Disorders, 23