Cerebral Embolic Protection during Transcatheter Aortic Valve Implantation: Updated Systematic Review and Meta-Analysis

被引:8
|
作者
Zahid, Salman [1 ]
Ullah, Waqas [2 ]
Khan, Muhammad Zia [3 ]
Uddin, Muhammad Faisal [1 ]
Rai, Devesh [1 ]
Abbas, Sakina [4 ]
Khan, Muhammad Usman [2 ]
Hussein, Ahmed [1 ]
Salama, Amr [1 ]
Bandyopadhyay, Dhrubajyoti [5 ]
Baibhav, Bipul [1 ]
Rao, Mohan [1 ]
Alam, Mahboob [6 ]
Alraies, M. Chadi [7 ]
Balla, Sudarshan [3 ]
Alkhouli, Mohamad [8 ]
Depta, Jeremiah P. [1 ]
机构
[1] Rochester Gen Hosp, Sands Constellat Heart Inst, Rochester, NY 14621 USA
[2] Thomas Jefferson Univ Hosp, Dept Cardiovasc Med, Philadelphia, PA USA
[3] West Virginia Univ, Heart & Vasc Inst, Div Cardiovasc Med, Morgantown, WV USA
[4] Dow Med Coll, Dept Med, Karachi, Pakistan
[5] New York Med Coll, Divi s Cardiovasc Med, Westchester Med Ctr, New York, NY USA
[6] Baylor Coll Med, Div Cardiol, Houston, TX USA
[7] Detroit Med Ctr, Div Cardiol, Detroit, MI USA
[8] Mayo Clin, Div Intervent Cardiol, Rochester, MN USA
关键词
REPLACEMENT; RISK; DEVICES; STROKE; SILENT; BRAIN; TAVI;
D O I
10.1016/j.cpcardiol.2022.101127
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In patient undergoing transcatheter aortic valve implantation (TAVI), stroke remains a poten-tially devastating complication associated with signifi-cant morbidity, and mortality. To reduce the risk of stroke, cerebral protection devices (CPD) were devel-oped to prevent debris from embolizing to the brain during TAVI. We performed a systematic review and meta-analysis to determine the safety and efficacy of CPD in TAVI. The MEDLINE (PubMed, Ovid) and Cochrane databases were queried with various combi-nations of medical subject headings to identify relevant articles. Statistical analysis was performed using a random-effects model to calculate unadjusted odds ratio (OR), including subgroup analyses based on fol-low-up duration, study design, and type of CPD. Using a pooled analysis, CPD was associated with a signifi-cant reduction in major adverse cardiovascular events MACE (OR 0.75, 95% CI 0.70-0.81, P < 0.01), mortal-ity (OR 0.65, 95% CI 0.58-0.74, P < 0.01) and stroke (OR 0.84, 95% CI 0.76-0.93, P < 0.01) in patients undergoing TAVI. Similarly, on MRI volume per lesion were lower for patients with CPD use. No signifi-cant difference was observed in acute kidney injury (OR 0.75, 95% CI 0.42-1.37, P = 0.68), bleeding (OR 0.92, 95% CI 0.71-1.20, P = 0.55) or vascular complica-tions (OR 0.90, 95% CI 0.62-1.31, P = 0.6) for patients undergoing TAVI with CPD. In conclusion, CPD device use in TAVI is associated with a reduction of MACE, mortality, and stroke compared with patients undergoing TAVI without CPD. However, the signifi-cant reduction in mortality is driven mainly by obser-vational studies. (Curr Probl Cardiol 2023;48:101127.)
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Cerebral Embolic Protection During Transcatheter Aortic Valve Implantation: Updated Systemic Review and Meta-Analysis
    Zahid, Salman
    Ubaid, Aamer
    Khan, Muhammad Atif
    Din, Mian Tanveer Ud
    Muhammadzai, Hamza Zahid Ullah
    Khan, Muhammmad
    Uddin, Muhammad Faisal
    Ullah, Waqas
    CIRCULATION, 2021, 144
  • [2] Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta-Analysis
    Testa, Luca
    Latib, Azeem
    Casenghi, Matteo
    Gorla, Riccardo
    Colombo, Antonio
    Bedogni, Francesco
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (10):
  • [3] Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta-analysis
    Testa, Luca
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (04) : S56 - S56
  • [4] Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta-analysis
    Testa, Luca
    Latib, Azeem
    Colombo, Antonio
    Bedogni, Francesco
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (16) : S62 - S63
  • [5] Cerebral Embolic Protection Devices During Transcatheter Aortic Valve Implantation Systematic Review and Meta-Analysis
    Bagur, Rodrigo
    Solo, Karla
    Alghofaili, Saleh
    Nombela-Franco, Luis
    Kwok, Chun Shing
    Hayman, Samual
    Siemieniuk, Reed A.
    Foroutan, Farid
    Spencer, Frederick A.
    Vandvik, Per O.
    Schaeufele, Tim G.
    Mamas, Mamas A.
    STROKE, 2017, 48 (05) : 1306 - +
  • [6] Meta-Analysis of Usefulness of Cerebral Embolic Protection During Transcatheter Aortic Valve Implantation
    Ahmad, Yousif
    Howard, James P.
    AMERICAN JOURNAL OF CARDIOLOGY, 2021, 146 : 69 - 73
  • [7] META-ANALYSIS ON CEREBRAL EMBOLIC PROTECTION DEVICES DURING TRANSCATHETER AORTIC VALVE IMPLANTATION
    Bagur, Rodrigo
    Solo, Karla
    Nombela-Franco, Luis
    Kwok, Chun Shing
    Mamas, Mamas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1303 - 1303
  • [8] Cerebral Embolic Protection in Transcatheter Aortic Valve Implantation Using the Sentinel Cerebral Protection System: A Systematic Review and Meta-Analysis
    Wissam Harmouch
    Barbara Karnkowska
    Ravi Thakker
    Peter Rasmussen
    Mostafa Shalaby
    Wissam Khalife
    Haider Alwash
    Afaq Motiwala
    Paul Kumfa
    Syed Gilani
    Hani Jneid
    Umamahesh Rangasetty
    Cardiology and Therapy, 2024, 13 : 299 - 314
  • [9] Cerebral Embolic Protection in Transcatheter Aortic Valve Implantation Using the Sentinel Cerebral Protection System: A Systematic Review and Meta-Analysis
    Harmouch, Wissam
    Karnkowska, Barbara
    Thakker, Ravi
    Rasmussen, Peter
    Shalaby, Mostafa
    Khalife, Wissam
    Alwash, Haider
    Motiwala, Afaq
    Kumfa, Paul
    Gilani, Syed
    Jneid, Hani
    Rangasetty, Umamahesh
    CARDIOLOGY AND THERAPY, 2024, 13 (02) : 299 - 314
  • [10] Stroke reduction by cerebral embolic protection devices in transcatheter aortic valve implantation: a systematic review and Bayesian meta-analysis
    Heuts, Samuel
    Gabrio, Andrea
    Veenstra, Leo
    Maesen, Bart
    Kats, Suzanne
    Maessen, Jos G.
    Walton, Antony S.
    Nanayakkara, Shane
    Lansky, Alexandra J.
    van 't Hof, Arnoud W. J.
    Vriesendorp, Pieter A.
    HEART, 2024, 110 (11) : 757 - 765