Experimental and numerical study of prefabricated steel frame with integrated wall panels

被引:7
|
作者
Fan, Min [1 ,4 ]
Guo, Hongchao [1 ,2 ,3 ]
Li, Shen [1 ,2 ]
Wang, Huaqiang [1 ]
Wang, Zhenshan [1 ,2 ]
Liang, Gang [1 ,2 ]
机构
[1] Xian Univ Technol, Sch Civil Engn & Architecture, 5 Jinhua Rd, Xian 710048, Peoples R China
[2] Xian Univ Technol, State Key Lab Base Ecohydraul Engn Arid Area, 5 Jinhua Rd, Xian 710048, Peoples R China
[3] Xian Univ Technol, Sch Civil Engn & Architecture, 5 Jinhua Rd, Xian 710048, Shaanxi, Peoples R China
[4] Xia Univ Technol, Sch Civil Engn & Architecture, 5 Jinhua Rd, Xian 710048, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Fully bolted prefabricated; Integrated wall panels; Steel frame; Joint types; Failure modes; PLATE SHEAR WALLS; THERMAL PERFORMANCE; SEISMIC BEHAVIOR; CONCRETE; SYSTEM; JOINT; BEAM;
D O I
10.1016/j.jcsr.2022.107746
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The suitability of external integrated lightweight thermal insulation decorative wall panels as a fully bolted prefabricated steel frame enclosure system was studied. The test on the fully bolted prefabricated steel frame with the external integrated lightweight thermal insulation decorative wall panels was completed under quasi -static cyclic loading, and the impact of the beam-column joint types were investigated. The failure mode, lateral stiffness, bearing capacity, energy dissipation capacity, ductility, and strain distribution were analyzed, and the internal forces of the steel frame were calculated. Experimental results show that the external integrated wall has minimal effect on the stiffness and bearing capacity of the fully bolted prefabricated steel frame. Furthermore, the L-shaped angle joints can increase the bearing capacity, energy dissipation capacity, and lateral stiffness evidently and move the joint plastic hinge outwards. The differences between the experimental bearing capacity and the theoretical value of the steel frame were minimal. Significant buckling deformation was observed at the beam-end, and progressive full-field strain at the plastic hinge were distributed in a band shape. The corre-sponding improved design was proposed. In addition, the failure mode and hysteretic behavior of the structures were studied by finite element analysis, and the influence of the main parameters, such as the number of hor-izontal and vertical plate bolts, the types of L-shaped angle stiffeners, and the height-span ratio and axial compression ratio of steel frame were discussed. The finite element analysis results were consistent with those of the test. It provided theoretical evidence for the design and application of fully bolted prefabricated steel frame with external integrated lightweight wall panels.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Numerical Study on Precast RC Wall Panels with Angle Steel Boundary Components
    Xu, Xiufeng
    Wang, Tao
    ADVANCES IN CIVIL STRUCTURES, PTS 1 AND 2, 2013, 351-352 : 578 - 582
  • [32] Research of construction and mechanism on prefabricated steel frame-damped enclosure wall
    Liang Z.
    Zhang C.
    Gao J.
    Deng X.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 : 62 - 70
  • [33] Experimental study on seismic performance of composite structure of steel column-integrated prefabricated concrete wall with different connection types
    Chen W.
    Tao Z.
    Yang Y.
    Bao W.
    Li Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (11): : 89 - 98
  • [34] Numerical Analysis and Experimental Study of Buckling Behavior of Steel Cylindrical Panels
    Shariati, M.
    Sedighi, M.
    Saemi, J.
    Poorfar, A. K.
    STEEL RESEARCH INTERNATIONAL, 2011, 82 (03) : 202 - 212
  • [35] Analysis on the mechanical properties of prefabricated steel frame-damped enclosure wall
    Santosa W.
    Zhang C.
    Wang H.
    Liang Z.
    Huang W.
    Chen Q.
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2022, 55 : 145 - 152
  • [36] On braced trapezoidal corrugated steel shear panels: An experimental and numerical study
    Vahid Amiri
    Arash Akbari Hamed
    Karim Abedi
    Frontiers of Structural and Civil Engineering, 2023, 17 : 396 - 410
  • [37] Experimental, numerical and theoretical study on the steel-grid-shear-wall connected to frame-beams only
    Chen, Zhihua
    Yang, Yan
    Yan, Xiangyu
    Zhang, Tianzhu
    Wen, Yuanhao
    Zhang, Mofan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 224
  • [38] On braced trapezoidal corrugated steel shear panels: An experimental and numerical study
    Amiri, Vahid
    Hamed, Arash Akbari
    Abedi, Karim
    FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2023, 17 (03) : 396 - 410
  • [39] Experimental study on seismic behavior of steel frame with damping infill wall
    Zou Z.
    Li S.
    Zhu Z.
    Zhang Z.
    Chang S.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2018, 39 : 71 - 78
  • [40] Experimental Study on Seismic Performance of Prefabricated Monolithic Concrete-Polystyrene Panel Composite Wall Panels
    Zhao, Kaozhong
    Fan, Zijia
    Zhang, Yuming
    Xu, Yufeng
    Liu, Sihong