Numerical study on the fire behaviour of restrained steel-concrete composite beams

被引:5
|
作者
Ding, Fa-xing [1 ,2 ]
Wang, Wenjun [1 ]
Jiang, Binhui [1 ]
机构
[1] Cent South Univ, Sch Civil Engn, Changsha 410075, Hunan, Peoples R China
[2] Engn Technol Res Ctr Prefabricated Construct Indus, Changsha 410075, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Restrained steel -concrete composite beam; Mechanical response; Catenary action; Overall lateral instability; Bending moment; RESISTANCE; COLUMNS; SLABS;
D O I
10.1016/j.jobe.2023.106358
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An elaborate solid-shell finite element model was developed to investigate the fire behavior of restrained steel-concrete composite beams. The model was validated against experimental results in literatures. Parametric studies were also performed to study the parameters including restraint stiffness, load ratio, span, exposure length, embedding depth, steel beam height and protective layer on the fire behavior of restrained composite beam. The analysis results show that the me-chanical response of restrained composite beams goes through four phases: elastic, elasto-plastic, rapid plastic deformation and plastic catenary action phase. With the decrease of restraint stiff-ness, the increase of load and span, the failure mode of the restrained composite beam changes from overall lateral instability to a sharp increase in deformation rate, and the code BS476-20 and ISO834 underestimate the fire resistance of restrained composite beams. The negative bending moment at the beam end increases sharply and reaches the peak value within a short fire time. Therefore, reinforcement shall be provided at the top of the concrete slab near the support sec-tion. Furthermore, the difference in fire resistance of restrained composite beams is mainly re-flected in the plastic catenary action phase. When the load ratio is less than 0.5, the fire resistance of restrained composite beams can be improved by reducing the fire range, beam height and span, and increasing the axial restraint stiffness. When the load ratio is 0.7, the fire resistance of restrained composite beam is hardly affected by the axial restraint stiffness and span, while with the exposure length reducing from 5 m to 4 m, embedded depth increasing from 0 mm to 50 mm, and the protective layer increasing from 0 mm to 10 mm, the fire resistance of the composite beams increases by 114 min and 160 min and 76 min, respectively.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Numerical evaluation for the effective slab width of steel-concrete composite beams
    Lasheen, Mahmoud
    Shaat, Amr
    Khalil, Ayman
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 148 : 124 - 137
  • [42] Experimental Study on Fire Behavior of Steel-Concrete Composite Cellular Beams with Large Opening Ratio
    Sunar Bukulmez, Pinar
    Celik, Oguz C.
    [J]. INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2020, 20 (01) : 207 - 231
  • [43] Numerical Analysis of the Fire Performance of Innovative Steel-Concrete Composite Columns
    Espinos, Ana
    Romero, Manuel L.
    Lam, Dennis
    [J]. STRUCTURES IN FIRE, 2016, : 552 - 559
  • [44] A simplified approach for fire-resistance design of steel-concrete composite beams
    Li, Guo-Qiang
    Wang, Wei-Yong
    [J]. STEEL AND COMPOSITE STRUCTURES, 2013, 14 (03): : 295 - 312
  • [45] Behaviour of steel-concrete composite columns
    Lakshmi, B
    Shanmugan, NE
    [J]. COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 449 - 456
  • [46] A review on fire resistance of steel-concrete composite slim-floor beams
    Memarzadeh, Armin
    Shahmansouri, Amir Ali
    Nematzadeh, Mahdi
    Gholampour, Aliakbar
    [J]. STEEL AND COMPOSITE STRUCTURES, 2021, 40 (01): : 13 - 32
  • [47] Fire experiment and fire design method of U-shaped steel-concrete composite beams
    Yang, Weiqi
    Yang, Yuanlong
    Liu, Faqi
    Chen, Yohchia Frank
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2024, 27 (02) : 233 - 252
  • [48] Strengthening of steel-concrete composite beams with composite slab
    Subhani, Mahbube
    Kabir, Muhammad Ikramul
    Al-Ameri, Riyadh
    [J]. STEEL AND COMPOSITE STRUCTURES, 2020, 34 (01): : 91 - 105
  • [49] Study on fatigue property of steel-concrete composite beams and studs
    Wang Yu-Hang
    Nie Jian-Guo
    Li Jian-Jun
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 94 : 1 - 10
  • [50] Experiment study on shear behavior of composite steel-concrete beams
    Fu, G.
    Xue, J. Y.
    Zhao, H. T.