Preliminary Investigation of Normal Pancreas Elasticity using Point Shear Wave Elastography

被引:0
|
作者
Almutairi, Fahad F. [1 ,2 ,3 ,4 ]
机构
[1] King Abdulaziz Univ, Fac Appl Med Sci, Dept Radiol Sci, Jeddah 21589, Saudi Arabia
[2] King Abdulaziz Univ, King Fahad Med Res Ctr, Anim House Unit, Jeddah 21589, Saudi Arabia
[3] King Abdulaziz Univ, Smart Med Imaging Res Grp, Jeddah 22252, Saudi Arabia
[4] King Abdulaziz Univ, Fac Appl Med Sci, Dept Diagnost Radiol, Jeddah 21589, Saudi Arabia
关键词
Point shear wave elastography; pancreas; asymptomatic; stiffness; shear wave velocity; CP; US; FORCE IMPULSE ARFI; SIZE; STIFFNESS; FIBROSIS;
D O I
10.2174/1573405619666230210151754
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Point shear wave elastography (pSWE) is used to provide quantitative information about the elasticity of the tissues. It has been used in many clinical applications to identify diseases early. This study aims to assess the suitability of pSWE to evaluate pancreas tissue stiffness and provide normal reference values for healthy pancreas tissues. Methods This study was conducted in the diagnostic department at a tertiary care hospital between October and December 2021. Sixteen healthy volunteers (eight men and eight women) participated. Pancreas elasticity measurements were obtained in different regions of interest (head, body, and tail). Scanning was performed by a certified sonographer using Philips EPIC7 ultrasound systems (Philips Ultrasound; Bothel, WA, USA). Results The mean velocity of the head of the pancreas was 1.3 & PLUSMN; 0.3 m/s (median: 1.2 m/s), the body was 1.4 & PLUSMN; 0.3 m/s (median: 1.4 m/s), and the tail was 1.4 & PLUSMN; 0.4 m/s (median: 1.2 m/s). The mean dimension was 17 & PLUSMN; 3 mm, 14 & PLUSMN; 4 mm, and 14 & PLUSMN; 6 mm for the head, body, and tail. The correlation of pancreas velocity across different segments and dimensions shows no significant difference with p values of 0.39 and 0.11, respectively. Conclusion This study shows that assessing the elasticity of the pancreas using pSWE is possible. A combination of SWVs measurements and dimensions could provide an early evaluation of pancreas status. Further studies including pancreatic disease patients are recommended.
引用
收藏
页码:1444 / 1448
页数:5
相关论文
共 50 条
  • [31] Shear wave elastography of the spleen using elastography point quantification: stiffness values in healthy children
    Bhatia, Anmol
    Bhatia, Harsimran
    Saxena, Akshay Kumar
    Lal, Sadhna B.
    Sodhi, Kushaljit Singh
    [J]. ABDOMINAL RADIOLOGY, 2022, 47 (06) : 2128 - 2134
  • [32] Shear wave elastography of the spleen using elastography point quantification: stiffness values in healthy children
    Anmol Bhatia
    Harsimran Bhatia
    Akshay Kumar Saxena
    Sadhna B. Lal
    Kushaljit Singh Sodhi
    [J]. Abdominal Radiology, 2022, 47 : 2128 - 2134
  • [33] Point Shear Wave Elastography for Splenic Assessment: A Comparative Study of Splenomegaly and Normal Spleens
    V. Patil, Parag
    Jain, Saksham
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (06)
  • [34] SHEAR WAVE ELASTOGRAPHY QUANTIFICATION OF BLOOD ELASTICITY DURING CLOTTING
    Bernal, Miguel
    Gennisson, Jean-Luc
    Flaud, Patrice
    Tanter, Mickael
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (12): : 2218 - 2228
  • [35] Exploring the anatomical factors influencing testes elasticity via ultrasound shear wave elastography: Preliminary results
    Lin, Yun-Yong
    Mao, Lin
    Li, Jin
    Zhu, Zhi-Min
    Luo, Yan-Hua
    Zhou, Xiao-Hua
    Qiu, Shao-Dong
    Chen, Fei
    [J]. REVISTA INTERNACIONAL DE ANDROLOGIA, 2023, 21 (04):
  • [36] Muscle elasticity in patients with neonatal brachial plexus palsy using shear-wave ultrasound elastography. Preliminary results
    Riquier-Le Chatelier, Morgane
    Giai, Joris
    Lallement-Dudek, Pauline
    Herisson, Olivier
    Fitoussi, Frank
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2021, 30 (04): : 385 - 392
  • [37] ELASTICITY MEASUREMENTS BY SHEAR WAVE ELASTOGRAPHY: COMPARISON AND SELECTION OF SHEAR WAVE, RAYLEIGH WAVE AND LAMB WAVE THEORY
    Xu, Hao
    Mo, Jian-Qiang
    Chen, Shigao
    An, Kai-Nan
    Luo, Zong-Ping
    [J]. JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2018, 18 (01)
  • [38] Comparison of 2 shear wave elastography systems in reproducibility and accuracy using an elasticity phantom
    Woo, Jung Han
    Ko, Eun Young
    Han, Boo-Kyung
    [J]. MEDICINE, 2021, 100 (15)
  • [39] A Preliminary Investigation of Normal Pancreas and Acute Pancreatitis Elasticity Using Virtual Touch Tissue Quantification (VTQ) Imaging
    Xie, Juan
    Zou, Liling
    Yao, Minghua
    Xu, Guang
    Zhao, Lixia
    Xu, Huixiong
    Wu, Rong
    [J]. MEDICAL SCIENCE MONITOR, 2015, 21 : 1693 - 1699
  • [40] Shear Wave Elastography in Placental Dysfunction Comparison of Elasticity Values in Normal and Preeclamptic Pregnancies in the Second Trimester
    Cimsit, Canan
    Yoldemir, Tevfik
    Akpinar, Ihsan Nuri
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (01) : 151 - 159