Biomechanical evaluation of the hybrid pedicle screw-cortical bone trajectory technique in transforaminal lumbar interbody fusion to adjacent segment degeneration-finite element analysis (vol 24, 409, 2023)

被引:1
|
作者
Zhang, Rui [1 ]
Kahaer, Alafate [2 ]
Niu, Hanqian [3 ]
Wang, Jingwen [1 ]
Jumahan, Ayididaer [4 ]
Qiu, Yanning [4 ]
Rexiti, Paerhati [2 ,5 ,6 ]
Guo, Hailong [2 ]
机构
[1] Xinjiang Med Univ, Clin Med Coll 2, Urumqi, Peoples R China
[2] Xinjiang Med Univ, Affiliated Hosp 1, Dept Spine Surg, 137 Liyushan South Rd, Urumqi, Peoples R China
[3] Xinjiang Med Univ, Clin Med Coll 5, Urumqi, Peoples R China
[4] Xinjiang Med Univ, Clin Med Coll 1, Urumqi, Peoples R China
[5] Xinjiang Med Univ, Xinjiang Key Lab High Incidence Dis Res, Minist Educ, Urumqi, Peoples R China
[6] Xinjiang Orthoped Clin Res Ctr, Urumqi, Peoples R China
关键词
Cortical bone trajectory screw; Finite element analysis; Lumbar spine; Pedicle screw; Transforaminal lumber interbody fusion;
D O I
10.1186/s12891-023-06646-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Transforaminal lumbar interbody fusion is an effective surgical treatment of intervertebral disk herniation. However, its clinical efficacy for adjacent segment disk degeneration (ASDD) after hybrid bilateral pedicle screw - bilateral cortical screw (pedicle screw at L4 and cortical bone trajectory screw at L5) and hybrid bilateral cortical screw - bilateral pedicle screw (bilateral cortical screw at L4 and bilateral pedicle screw at L5) remains undiscovered. Therefore, the aim of this study is to evaluate the effect of the hybrid bilateral pedicle screw - bilateral cortical screw and hybrid bilateral cortical screw - bilateral pedicle screw on the adjacent segment via a 3-dimensional (3D) finite element (FE) analysis. Methods: Four human cadaveric lumbar spine specimens were provided by the anatomy teaching and research department of Xinjiang Medical University. Four finite element models of L1-S1 lumbar spine segment were generated. For each of these, four lumbar transforaminal lumbar interbody fusion models at L4-L5 segment with the following instruments were created: hybrid bilateral pedicle screw - bilateral cortical screw, bilateral cortical screw - bilateral cortical screw (bilateral cortical screw at both L4 and L5 segments), bilateral pedicle screw - bilateral pedicle screw (bilateral pedicle screw at both L4 and L5 segments), and hybrid bilateral cortical screw - bilateral pedicle screw. A 400-N compressive load with 7.5 Nm moments was applied for the simulation of flexion, extension, lateral bending, and rotation. The range of motion of L3-L4 and L5-S1 segments and von Mises stress of the intervertebral disc at the adjacent segment were compared. Results: Hybrid bilateral pedicle screw - bilateral cortical screw has the lowest range of motion at L3-L4 segment in flexion, extension, and lateral bending, and the highest disc stress in all motions, while the range of motion at L5-S1 segment and disc stress was lower than bilateral pedicle screw - bilateral pedicle screw in flexion, extension, and lateral bending, and higher than bilateral cortical screw - bilateral cortical screw in all motions. The range of motion of hybrid bilateral cortical screw - bilateral pedicle screw at L3-L4 segment was lower than bilateral pedicle screw - bilateral pedicle screw and higher than bilateral cortical screw - bilateral cortical screw in flexion, extension, and lateral bending, and the range of motion at L5-S1 segment was higher than bilateral pedicle screw - bilateral pedicle screw in flexion, lateral bending, and axial rotation. The disc stress at L3-L4 segment was lowest and more dispersed in all motions, and the disc stress at L5-S1 segment was higher than bilateral pedicle screw - bilateral pedicle screw in lateral bending and axial rotation, but more dispersed. Conclusion: Hybrid bilateral cortical screw - bilateral pedicle screw decreases the impact on adjacent segments after spinal fusion, reduces the iatrogenic injury to the paravertebral tissues, and provides throughout decompression of the lateral recess. © 2023, The Author(s).
引用
收藏
页数:1
相关论文
共 29 条
  • [21] Biomechanical investigation of the hybrid modified cortical bone screw-pedicle screw fixation technique: Finite-element analysis
    Kahaer, Alafate
    Maimaiti, Xieraili
    Maitirouzi, Julaiti
    Wang, Shuiquan
    Shi, Wenjie
    Abuduwaili, Nueraihemaiti
    Zhou, Zhihao
    Liu, Dongshan
    Maimaiti, Abulikemu
    Rexiti, Paerhati
    FRONTIERS IN SURGERY, 2022, 9
  • [22] Comparative Study of Two Surgical Techniques for Proximal Adjacent Segment Pathology after Posterior Lumbar Interbody Fusion with Pedicle Screws: Fusion Extension using Conventional Pedicle Screw vs Cortical Bone Trajectory-Pedicle Screw (Cortical Screw)
    Lee, Gun Woo
    Shin, Ji-Hoon
    WORLD NEUROSURGERY, 2018, 117 : E154 - E161
  • [23] Iatrogenic muscle damage in transforaminal lumbar interbody fusion and adjacent segment degeneration: a comparative finite element analysis of open and minimally invasive surgeries
    Kumaran, Yogesh
    Shah, Anoli
    Katragadda, Akhil
    Padgaonkar, Adit
    Zavatsky, Joseph
    McGuire, Robert
    Serhan, Hassan
    Elgafy, Hossein
    Goel, Vijay K.
    EUROPEAN SPINE JOURNAL, 2021, 30 (09) : 2622 - 2630
  • [24] Iatrogenic muscle damage in transforaminal lumbar interbody fusion and adjacent segment degeneration: a comparative finite element analysis of open and minimally invasive surgeries
    Yogesh Kumaran
    Anoli Shah
    Akhil Katragadda
    Adit Padgaonkar
    Joseph Zavatsky
    Robert McGuire
    Hassan Serhan
    Hossein Elgafy
    Vijay K. Goel
    European Spine Journal, 2021, 30 : 2622 - 2630
  • [25] Biomechanical Changes of Adjacent and Fixed Segments Through Cortical Bone Trajectory Screw Fixation versus Traditional Trajectory Screw Fixation in the Lumbar Spine: A Finite Element Analysis
    Zhang, Lai
    Li, Hui-Min
    Zhang, Renjie
    Zhang, Huaqing
    Shen, Cai-Liang
    WORLD NEUROSURGERY, 2021, 151 : E447 - E456
  • [26] Comparative effectiveness of cortical bone trajectory screws and pedicle screws in the treatment of adjacent segment degeneration after lumbar fusion surgery: a systematic review and meta-analysis
    Shang, Qisong
    Luan, Haopeng
    Peng, Cong
    Song, Xinghua
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [27] May the midline lumbar interbody fusion (MIDLIF) prevent the early radiographic adjacent segment degeneration? A minimum 3-year follow-up comparative study of MIDLIF in L4/5 with cortical bone trajectory screw versus traditional pedicle screw fixation
    Bo Han
    Hongtao Ding
    Yong Hai
    Yuzeng Liu
    Li Guan
    Aixing Pan
    Xinuo Zhang
    Peng Yin
    BMC Musculoskeletal Disorders, 23
  • [28] May the midline lumbar interbody fusion (MIDLIF) prevent the early radiographic adjacent segment degeneration? A minimum 3-year follow-up comparative study of MIDLIF in L4/5 with cortical bone trajectory screw versus traditional pedicle screw fixation
    Han, Bo
    Ding, Hongtao
    Hai, Yong
    Liu, Yuzeng
    Guan, Li
    Pan, Aixing
    Zhang, Xinuo
    Yin, Peng
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [29] Biomechanical advantages of robot-assisted pedicle screw fixation in posterior lumbar interbody fusion compared with freehand technique in a prospective randomized controlled trial-perspective for patient-specific finite element analysis
    Kim, Ho-Joong
    Kang, Kyoung-Tak
    Park, Sung-Cheol
    Kwon, Oh-Hyo
    Son, Juhyun
    Chang, Bong-Soon
    Lee, Choon-Ki
    Yeom, Jin S.
    Lenke, Lawrence G.
    SPINE JOURNAL, 2017, 17 (05): : 671 - 680