A phased array ultrasound system with a robotic arm for neuromodulation

被引:3
|
作者
Seo, Jongbum [1 ]
Shin, Hyunsoo [2 ]
Cho, Sungtaek [2 ]
Lee, Sungon [2 ]
Ryu, Wooseok [3 ]
Han, Su-Cheol [4 ]
Kim, Da Hee [4 ]
Kang, Goo Hwa [4 ]
机构
[1] Yonsei Univ, Dept Biomed Engn, Wonju, Gangwon Do, South Korea
[2] Hanyang Univ ERICA Campus, Sch Elect Engn, Ansan, Gyeonggi Do, South Korea
[3] Yonsei Univ, Sch Mech Engn, Seoul, South Korea
[4] KRICT, Jeonbuk Dept Inhalat Res, KIT, Daejeon, South Korea
基金
新加坡国家研究基金会;
关键词
Neuromodulation; Ultrasonic neuromodulation; Cortical column; Phased-array transducer; TRANSCRANIAL FOCUSED ULTRASOUND; NONINVASIVE BRAIN-STIMULATION; NEUROSTIMULATION; OPTIMIZATION; SUPPRESSION; DESIGN; TISSUE;
D O I
10.1016/j.medengphy.2023.104023
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Ultrasonic neuromodulation (UNMOD) provides a non-invasive brain stimulation. However, the high-resolution region-specificity of UNMOD with a single element transducer combined with a mechanical positioning system could have limits due to the intrinsic positioning error from mechanical systems. Objective/Hypothesis: A phased array system could lead to highly selective neuromodulation with electronic control.Methods: A specialized phased-array system with a robotic arm is implemented for a rhesus monkey model. Various primary motor cortex areas related to tail, hand, and mouth were stimulated with a 200 & mu;m step size. The ultrasonic parameters were ISPTA of 840 mW/cm2, pulse repetition frequency of 100 Hz, and a 5% duty factor at 600 kHz. The induced movement were recorded and analyzed. Results: Separate digits, mouth, and tongue motions were successfully induced by electronically controlling the focus. The identical body part movement could be induced when the focus was moved back to the identical primary motor cortex with electronic control. Accordingly, the reproducibility of UNMOD could be partially validated with rhesus monkey model.Conclusion: A phased-array system appears to have a potential for the non-invasive and region-selective neuromodulation method.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] A sixteen-channel phased array driving system for ultrasound hyperthermia
    Lu, BY
    Lin, WL
    Chen, YY
    Kuo, TS
    Wang, CY
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 822 - 825
  • [22] Design and Optimization of Ultrasound Phased Arrays for Large-Scale Ultrasound Neuromodulation
    Ilham, Sheikh Jawad
    Kashani, Zeinab
    Kiani, Mehdi
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2021, 15 (06) : 1454 - 1466
  • [23] DESIGN OF A SIMPLIFIED DELAY SYSTEM FOR ULTRASOUND PHASED-ARRAY IMAGING
    MANES, GF
    ATZENI, C
    SUSINI, C
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1983, 30 (06): : 350 - 354
  • [24] Phased Array Ultrasound System for Planar Flow Mapping in Liquid Metals
    Maeder, Kevin
    Nauber, Richard
    Galindo, Vladimir
    Beyer, Hannes
    Buttner, Lars
    Eckert, Sven
    Czarske, Juergen
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (09) : 1327 - 1335
  • [25] Design and evaluation of a feedback based phased array system for ultrasound surgery
    Harvard Medical Sch, Boston, MA, United States
    IEEE Trans Ultrason Ferroelectr Freq Control, 2 (431-438):
  • [26] Design and evaluation of a feedback based phased array system for ultrasound surgery
    Daum, DR
    Buchanan, MT
    Fjield, T
    Hynynen, K
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (02) : 431 - 438
  • [27] Ultraino: An Open Phased-Array System for Narrowband Airborne Ultrasound Transmission
    Marzo, Asier
    Corkett, Tom
    Drinkwater, Bruce W.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (01) : 102 - 111
  • [28] New phased array ultrasound system based on Dsp/Bios and Pci bus
    Zhang, XF
    Shi, KR
    Zheng, LN
    ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 : 154 - 159
  • [29] DYNAMIC CARDIAC IMAGING USING A FOCUSED, PHASED-ARRAY ULTRASOUND SYSTEM
    KISSLO, JA
    VONRAMM, OT
    THURSTONE, FL
    AMERICAN JOURNAL OF MEDICINE, 1977, 63 (01): : 61 - 68
  • [30] Development of the phased array ultrasound system for nondestructive testing and its key techniques
    Xu, XG
    Shi, KR
    Chen, YF
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 221 - 225