Improving radiation dosimetry with an automated micronucleus scoring system: correction of automated scoring errors

被引:1
|
作者
Lee, Younghyun [1 ,4 ]
Jin, Young Woo [2 ]
Seong, Ki Moon [1 ]
Wilkins, Ruth C. [3 ]
Jang, Seongjae [1 ]
机构
[1] Korea Inst Radiol & Med Sci, Natl Radiat Emergency Med Ctr, Lab Biol Dosimetry, Seoul, South Korea
[2] Korea Inst Radiol & Med Sci, Natl Radiat Emergency Med Ctr, Seoul, South Korea
[3] Hlth Canada, Consumer & Clin Radiat Protect Bur, Ottawa, ON, Canada
[4] Soonchunhyang Univ, Coll Med Sci, Dept Biomed Lab Sci, Asan, South Korea
关键词
Biodosimetry; Micronuclei assay; Automated scoring; Radiation exposure; CHROMOSOME-ABERRATIONS; HIGH-THROUGHPUT; DNA-DAMAGE; WORKERS; ASSAY; FREQUENCY; PROTOCOL; PROJECT; BIODOSIMETRY; CRITERIA;
D O I
10.1007/s00411-023-01030-7
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Radiation dose estimations performed by automated counting of micronuclei (MN) have been studied for their utility for triage following large-scale radiological incidents; although speed is essential, it also is essential to estimate radiation doses as accurately as possible for long-term epidemiological follow-up. Our goal in this study was to evaluate and improve the performance of automated MN counting for biodosimetry using the cytokinesis-block micronucleus (CBMN) assay. We measured false detection rates and used them to improve the accuracy of dosimetry. The average false-positive rate for binucleated cells was 1.14%; average false-positive and -negative MN rates were 1.03% and 3.50%, respectively. Detection errors seemed to be correlated with radiation dose. Correction of errors by visual inspection of images used for automated counting, called the semi-automated and manual scoring method, increased accuracy of dose estimation. Our findings suggest that dose assessment of the automated MN scoring system can be improved by subsequent error correction, which could be useful for performing biodosimetry on large numbers of people rapidly, accurately, and efficiently.
引用
收藏
页码:349 / 356
页数:8
相关论文
共 50 条
  • [41] DEVELOPMENT OF A SOFTWARE SYSTEM FOR AUTOMATED TEST ASSEMBLY AND SCORING
    Bosnjakovic, Andrija
    Protic, Jelica
    Tartalja, Igor
    3RD INTERNATIONAL CONFERENCE OF EDUCATION, RESEARCH AND INNOVATION (ICERI2010), 2010,
  • [42] An efficient automated answer scoring system for Punjabi language
    Walia, Tarandeep Singh
    Josan, Gurpreet Singh
    Singh, Amarpal
    EGYPTIAN INFORMATICS JOURNAL, 2019, 20 (02) : 89 - 96
  • [43] Application of automated scoring system of dicentric chromosome for biodosimetry
    Ishii, Kotaro
    Akiyama, Miho
    Kamimoto, Kenji
    Kawai, Hiroki
    Suto, Yumiko
    CYTOLOGIA, 2023, 88 (04)
  • [44] PERFORMANCE OF THE AUTOMATED COMPLETE SELVESTER QRS SCORING SYSTEM
    PAHLM, O
    HAISTY, WK
    WAGNER, NB
    SELVESTER, RH
    POPE, JE
    WAGNER, GS
    JOURNAL OF ELECTROCARDIOLOGY, 1991, 23 : 28 - 28
  • [45] Content Modeling for Automated Oral Proficiency Scoring System
    Yoon, Su-Youn
    Lee, Chong Min
    INNOVATIVE USE OF NLP FOR BUILDING EDUCATIONAL APPLICATIONS, 2019, : 394 - 401
  • [46] An assessment of the performance of an automated scoring system (Cellomics) for the in vitro micronucleus assay in CHO-K1 cells
    Scott, Andrew
    Malcomber, Sophie
    Maskell, Sharon
    Moore, Claire
    Windebank, Sam
    Diaz, Dolores
    Carmichael, Paul
    TOXICOLOGY, 2007, 231 (2-3) : 111 - 112
  • [47] Differentiation of Aneugens and Clastogens in the In Vitro Micronucleus Test by Kinetochore Scoring Using Automated Image Analysis
    Wilde, Sabrina
    Queisser, Nina
    Holz, Christian
    Raschke, Marian
    Sutter, Andreas
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2019, 60 (03) : 227 - 242
  • [48] Semi-automated micronucleus-centromere scoring in assessing cellular damage in patients exposed to low doses of ionizing radiation
    Baeyens, A.
    Slabbert, J. P.
    Swanson, R.
    Thierens, H.
    Willem, P.
    Vral, A.
    INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE, 2010, 26 : S58 - S58
  • [49] CYTOKINESIS-BLOCK MICRONUCLEUS ASSAY BY MANUAL AND AUTOMATED SCORING: CALIBRATION CURVES AND DOSE PREDICTION
    De Sanctis, S.
    De Amicis, A.
    Di Cristofaro, S.
    Franchini, V.
    Regalbuto, E.
    Mammana, G.
    Lista, F.
    HEALTH PHYSICS, 2014, 106 (06): : 745 - 749
  • [50] Automated tools for subject matter expert evaluation of automated scoring
    Williamson, DM
    Bejar, II
    Sax, A
    APPLIED MEASUREMENT IN EDUCATION, 2004, 17 (04) : 323 - 357