Color Stability and Degree of Conversion of Light-cured Resin Cements

被引:0
|
作者
Andreucci, Ana Carolina [1 ,2 ]
Baroudi, Kusai [3 ,4 ]
Freitas, Maiara Rodrigues [1 ,2 ]
Amaral, Marina [2 ,5 ]
Aguiar, Flavio Baggio [6 ,7 ]
Zanatta, Rayssa Ferreira [8 ,9 ]
Suzy Liporoni, Priscila Christiane [1 ,2 ]
机构
[1] Univ Taubate, Dept Restorat Dent, Taubate, SP, Brazil
[2] Univ Taubate, Dept Odontol, Unitau, Taubate, SP, Brazil
[3] RAK Med & Hlth Sci Univ, RAK Coll Dent Sci, Ras Al Khaymah, U Arab Emirates
[4] Univ Taubate, Sch Dent, Taubate, SP, Brazil
[5] Univ Taubate, Sch Dent, Dept Prosthodont Dent, Taubate, SP, Brazil
[6] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Restorat Dent, Piracicaba, SP, Brazil
[7] Univ Estadual Campinas, Dept Odontol Restauradora, Fac Odontol Piracicaba, UNICAMP, Campinas, Brazil
[8] Univ Brasilia UnB, Sch Hlth Sci, Dept Dent, Brasilia, Brazil
[9] Univ Brasilia, Dept Odontol, Facdade Ciencias Saude, Brasilia, DF, Brazil
来源
OPEN DENTISTRY JOURNAL | 2023年 / 17卷
关键词
Resin cements; Alternative photoinitiators; Ceramic veneers; Color stability; Variolink cement; Patients; LUTING CEMENT; LAMINATE; VENEERS;
D O I
10.2174/18742106-v17-e230518-2023-19
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the color stability and degree of conversion of light-cured resin cement with different activator-initiator systems using LED lights with different wavelengths (polywave x monowave). Materials and Methods: Sixteen resin cement samples were made using a circular silicone matrix (7 mm diameter, 0.5 mm thickness) for each of the following tested materials: Variolink Esthetic LC (Ivoclar, color Light+); RelyX Veneer (3M ESPE, color A1); Filtek Z350XT flow resin (3M ESPE, color A1); Allcem Veneer APS (FGM, color A1); NX3 Light cure (Kerr, color A1). Half of the samples were photocured with a monowave LED light (Elipar Deep Cure), and the other half with a polywave LED light (Valo Grand). The initial color of each cement was measured using a high translucency ceramic sample simulating ceramic venner. Color measurements were performed with a reflectance colorimetric spectrophotometer and the data was collected according to the CIE L* a* b* system in two steps. The degree of conversion was measured using an infrared spectrometer by Fourier transform (FTIR / ATR) and the absorbance method. Statistical analysis was performed using ANOVA repeated measures and Tukey's post hoc tests (p <0.05). Results: For the color analysis, there were no significant differences between the cement related to time versus light curing (p = 0.084) and also related to time versus cement versus light curing (p = 0.142). Among the factors, there was only a statistically significant difference for the type of cement (p <0.01). In contrast, for the photocuring device (p = 0.504) and the interaction between them (p = 0.738), there was no significant difference. For the degree of conversion analysis, it showed a statistically significant difference for both factors, resin cements (p <0.01) and light curing units (p <0.01). Conclusion: The color stability of RelyX cement is low compared to other cements, while Variolink cement presented the best degree of the conversion value.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Evaluation of the Degree of Conversion, Residual Monomers and Mechanical Properties of Some Light-Cured Dental Resin Composites
    Moldovan, Marioara
    Balazsi, Robert
    Soanca, Andrada
    Roman, Alexandra
    Sarosi, Codruta
    Prodan, Doina
    Vlassa, Mihaela
    Cojocaru, Ileana
    Saceleanu, Vicentiu
    Cristescu, Ioan
    MATERIALS, 2019, 12 (13)
  • [22] The difference in degree of conversion between light-cured and additional heat-cured composites
    Park, SH
    Lee, CS
    OPERATIVE DENTISTRY, 1996, 21 (05) : 213 - 217
  • [23] The effect of curing light and chemical catalyst on the degree of conversion of two dual cured resin luting cements
    Eduardo José Souza-Junior
    Lúcia Trazzi Prieto
    Giulliana Panfiglio Soares
    Carlos Tadeu dos Santos Dias
    Flávio Henrique Baggio Aguiar
    Luís Alexandre Maffei Sartini Paulillo
    Lasers in Medical Science, 2012, 27 : 145 - 151
  • [24] Influence of the composition and shades of ceramics on light transmission and degree of conversion of dual-cured resin cements
    de Mendonca, Luana Menezes
    Ramalho, Ilana Santos
    Santos Nogueira Limas, Livia Aguiar
    Pires, Lais Alcantara
    Pegoraro, Thiago Amadei
    Pegoraro, Luiz Fernando
    JOURNAL OF APPLIED ORAL SCIENCE, 2019, 27
  • [25] The effect of curing light and chemical catalyst on the degree of conversion of two dual cured resin luting cements
    Souza-Junior, Eduardo Jose
    Prieto, Lucia Trazzi
    Soares, Giulliana Panfiglio
    dos Santos Dias, Carlos Tadeu
    Baggio Aguiar, Flavio Henrique
    Maffei Sartini Paulillo, Luis Alexandre
    LASERS IN MEDICAL SCIENCE, 2012, 27 (01) : 145 - 151
  • [26] Color stability of a new light-cured ceramic stain system
    Lee, S
    Nathanson, D
    Giordano, R
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 123 - 123
  • [27] COLOR STABILITY OF LIGHT-CURED GLASS IONOMERS AFTER STERILIZATION
    OKEEFE, KL
    BERRY, E
    POWERS, JM
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 108 - 108
  • [28] EFFECTS OF 2 AMINE REDUCING AGENTS ON THE DEGREE OF CONVERSION AND PHYSICAL-PROPERTIES OF AN UNFILLED LIGHT-CURED RESIN
    YOSHIDA, K
    GREENER, EH
    DENTAL MATERIALS, 1993, 9 (04) : 246 - 251
  • [29] LIGHT-CURED RESIN FOR POST PATTERNS
    WALDMEIER, MD
    GRASSO, JE
    JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (03): : 412 - 415
  • [30] Degree of conversion and color stability of the light curing resin with new photoinitiator systems
    Shin, Dong-Hoon
    Rawls, H. Ralph
    DENTAL MATERIALS, 2009, 25 (08) : 1030 - 1038