Enhanced pool boiling of refrigerants R-134a, R-1336mzz(Z) and R-1336mzz(E) on micro- and nanostructured tubes

被引:2
|
作者
Fu, Wuchen [1 ]
Chen, Yiyang [1 ]
Inanlu, Mohammad Jalal [1 ]
Thukral, Tarandeep Singh [1 ]
Li, Jiaqi [1 ]
Miljkovic, Nenad [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Illinois, Dept Mech Sci & Engn, Urbana, IL 61820 USA
[2] Univ Illinois, Mat Res Lab, Urbana, IL 61820 USA
[3] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61820 USA
[4] Univ Illinois, Inst Sustainabil Energy & Environm, Urbana, IL 61820 USA
[5] Kyushu Univ, Int Inst Carbon Neutral Energy Res WPI I2CNER, 744 Motooka,Nishi Ku, Fukuoka 8190395, Japan
关键词
Refrigerant; Bubble; Surface tension; Etching; Oxidation; Chiller; Electronics cooling; Low-GWP; Electrification; Decarbonization; HEAT-TRANSFER COEFFICIENTS; LOW-GWP REFRIGERANTS; R1233ZD(E); SURFACES; DROP;
D O I
10.1016/j.ijheatmasstransfer.2023.124983
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pool boiling of refrigerants is a primary heat transfer mode in flooded evaporators, as well as a promising solution in electronics cooling applications. In this work, the pool boiling performance of R-134a, R-1336mzz(E), and R-1336mzz(Z) on the external side of round tubes are reported and compared to Cooper's heat transfer coefficient (HTC) model. Modification of Cooper's correlation is found to be necessary for R-1336mzz(Z) at low reduced pressure. Micro- and nanostructured tubes are tested using the three different refrigerants and are shown to enhance the boiling HTC. Specifically, three various structures consisting of: boehmite (AlO(OH)) nanostructures, etched aluminum microstructures, and copper oxide (CuO) micro-nanostructures are fabricated on the external sides of aluminum and copper tubes. The surface structures have characteristic length scales of 100 nm, 1 mu m, and 10 mu m for boehmite, CuO, and etched aluminum, respectively. While the boiling HTC is enhanced up to 250% (compared to smooth tubes) using R-134a with etched aluminum, it shows a 15% decrease in HTC when boehmite structures are used. For CuO, higher heat fluxes showed a 25% HTC enhancement, while lower heat fluxes showed negligible effects when compared to smooth copper tubing. Different refrigerants showed various relations between structure and HTC enhancements. To take account of both structure length scale and refrigerant properties, we introduce a normalized structure size (Rn) and conclude that HTC enhancement ratio increases non-linearly with Rn. Our study not only provides valuable data on refrigerant pool boiling of recently developed low global warming potential and ozone depleting potential fluids, it also provides valuable design guidelines for the development and application of micro- and nanostructured surfaces in chiller and electronics cooling applications.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Surface Tension and Parachor of cis- and trans-1,1,1,4,4,4-Hexafluorobutene [R-1336mzz(Z) and R-1336mzz(E)]
    Kawahara, Takemasa
    Kondou, Chieko
    Iwasaki, Shun
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2023, 68 (12): : 3316 - 3327
  • [2] Chemical Stability Investigations of UltraLow GWP Refrigerants R-1336mzz(Z), R1336mzz(E), R-514A, R-1233zd(E), and R1224yd(Z) with Lubricants
    Kujak, Steve
    Sorenson, Elyse
    Leehey, Morgan Herried
    Robaczewski, Cameron
    Stellpflug, Trever
    Wang, Xudong
    ASHRAE TRANSACTIONS 2022, VOL 128, PT 2, 2022, 128 : 193 - 200
  • [3] Speed of Sound Measurements of R-1130(E) and an Azeotropic Blend of R-1336mzz(Z)/1130(E)
    Rowane, Aaron J.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2024, 45 (10)
  • [4] Pool Boiling of R514A, R1224 yd(Z), and R1336mzz(E) on a Reentrant Cavity Surface
    Kedzierski, M. A.
    Lin, L.
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2021, 143 (05):
  • [5] A NON-FLAMMABLE LOW GWP REFRIGERANT FOR CENTRIFUGAL CHILLERS AND HIGH TEMPERATURE HEAT PUMPS: R-1336mzz(Z)
    Juhasz, Jason
    Kontomaris, Konstantinos
    1ST IIR INTERNATIONAL CONFERENCE ON THE APPLICATION OF HFO REFRIGERANTS, 2018, : 231 - 237
  • [6] Measurement of Viscosity of cis-1,1,1,4,4,4-Hexafluoro-2-butene (R-1336mzz(Z)) by Tandem Capillary Tubes Method
    Alam, Md Jahangir
    Miyara, Akio
    Kariya, Keishi
    Kontomaris, Konstantinos Kostas
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2018, 63 (05): : 1706 - 1712
  • [7] Experimental investigation on self-induced jet impingement boiling using R1336mzz(Z)
    Xu, Jinyang
    Hong, Fangjun
    Zhang, Chaoyang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 220
  • [8] R1234ze-Z和R1336mzz-E组合物物性研究
    张董鑫
    欧阳洪生
    张凯
    管祥添
    傅荣幸
    郭智恺
    制冷与空调, 2021, 21 (07) : 81 - 87
  • [9] Bubble Point Measurements of cis-1,1,1,4,4,4-Hexafluorobutene [R-1336mzz(Z)] + trans-1,2-Dichloroethene [R-1130(E)] mixtures
    Rowane, Aaron J.
    Outcalt, Stephanie L.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2024, 45 (07)
  • [10] Experimental and theoretical study on liquid viscosity of R1336mzz(E)
    Xu, Chenyi
    Ye, Gongran
    Guo, Haowen
    Zhuang, Yuan
    Guo, Zhikai
    Han, Xiaohong
    Chen, Guangming
    Huagong Xuebao/CIESC Journal, 2021, 72 (06): : 3261 - 3269