Investigating the electrode-electrolyte interface modelling in cochlear implants

被引:3
|
作者
Molaee-Ardekani, Behnam [1 ]
Donahue, Mary J. [2 ]
机构
[1] Oticon Med, Vallauris, France
[2] Linkoping Univ, Linkoping, Sweden
关键词
cochlear implants; electrode-tissue; modelling; cole model; electrode-electrolyte interface; IMPEDANCE; IDENTIFICATION; TISSUE;
D O I
10.1088/2057-1976/aceafb
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective. Proposing a good electrode-electrolyte interface (EEI) model and properly identifying relevant parameters may help designing safer and more optimized auditory nerve fiber stimulation and recording in cochlear implants (CI). However, in literature, EEI model parameter values exhibit large variability. We aim to explain some root causes of this variability using the Cole model and its simpler form, the Basic RC model. Approach. We use temporal and spectral methods and fit the models to stimulation pulse voltage response (SPVR) and electrochemical impedance spectroscopy (EIS) data. Main Results. Temporal fittings show that there are multiple sets of model parameters that provide a good fit to the SPVR data. Therefore, small methodological differences in literature may result in different model fits. While these models share similar characteristics at high frequencies >500 Hz, the SPVR fitting is blind to low frequencies, thus it cannot correctly estimate the Faradaic resistor. Similarly, the polarization capacitor and its fractional order are not estimated robustly (capacitor variations in the nano- to micro-farad range) due to limited observation of mid-range frequencies. EIS provides a good model fit down to & SIM;3Hz, and thus robust estimation for the polarization capacitor. At lower frequencies charge mechanisms may modify the EEI, requiring multi-compartment Cole model fitting to EIS to improve the estimation of Faradaic characteristics. Our EIS data measurements down to 0.05Hz show that a two-compartment Cole model is sufficient to explain the data. Significance. Our study describes the scope and limitation of SPVR and EIS fitting methods, by which literature variability is explained among CI EEI models. The estimation of mid-to-low-frequency characteristics of the CI EEI is not in the scope of the SPVR method. EIS provides a better fit; however, its results should not be extrapolated to unobserved frequencies where new charge transfer mechanisms may emerge at the EEI.
引用
收藏
页数:15
相关论文
共 50 条
  • [32] Probing the Electrode-Electrolyte Interface with In-Operando Neutron Scattering
    Bridges, Craig
    Jafta, Charl
    Sun, Xiaoguang
    Parans, Mariappan
    Paranthaman
    Heller, William
    Dai, Sheng
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2018, 74 : A395 - A395
  • [33] Non linear fractal impedance model of an electrode-electrolyte interface
    Ruiz, G
    Felice, CJ
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 2315 - 2318
  • [34] INFLUENCE OF ZEOLITE AS MEDIUM ON THE POLYMERIZATION OF ANILINE AT THE ELECTRODE-ELECTROLYTE INTERFACE
    PHANI, KLN
    PITCHUMANI, S
    RAVICHANDRAN, S
    LANGMUIR, 1993, 9 (09) : 2455 - 2459
  • [35] Relaxation processes due to the electrode-electrolyte interface in ionic solutions
    Sanabria, Hugo
    Miller, John H., Jr.
    PHYSICAL REVIEW E, 2006, 74 (05):
  • [36] Electrode-Electrolyte Interface Modeling and Impedance Characterizing of Tripolar Concentric Ring Electrode
    Nasrollaholhosseini, Seyed Hadi
    Mercier, Jason
    Fischer, Godi
    Besio, Walter G.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (10) : 2897 - 2905
  • [37] Microscopic Imaging of Electrical Current Distribution at the Electrode-Electrolyte Interface
    Jia, Wenyan
    Wu, Jiamin
    Gao, Di
    Sun, Mingui
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 4252 - 4255
  • [38] THE LINEAR AND NONLINEAR ELECTRICAL-PROPERTIES OF THE ELECTRODE-ELECTROLYTE INTERFACE
    MCADAMS, ET
    LACKERMEIER, A
    MCLAUGHLIN, JA
    MACKEN, D
    JOSSINET, J
    BIOSENSORS & BIOELECTRONICS, 1995, 10 (1-2): : 67 - 74
  • [39] Evolution of the electrode-electrolyte interface in a lithium-polymer battery
    Teyssot, A
    Rosso, M
    Bouchet, R
    Lascaud, S
    SOLID STATE IONICS, 2006, 177 (1-2) : 141 - 143
  • [40] Electrode roughness effect on the electrode-electrolyte interface DC current-potential curves
    Felice, CJ
    Ruiz, GR
    Madrid, RE
    Valentinuzzi, ME
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1677 - 1678