Agreement between a new optical low coherence reflectometry biometer and an anterior segment optical coherence tomographer

被引:3
|
作者
Wang, Yiran [1 ,2 ,3 ,5 ,6 ]
Wan, Ting [5 ,6 ]
Liu, Luze [5 ,6 ]
Xue, Yuyuan [1 ,2 ,3 ]
Chen, Xinyao [1 ,2 ,3 ]
Savini, Giacomo [7 ]
Schiano-Lomoriello, Domenico [7 ]
Zhou, Xingtao [1 ,2 ,3 ,4 ]
Yu, Jinjin [1 ,2 ,3 ,4 ]
Huang, Jinhai [1 ,2 ,3 ,4 ]
机构
[1] Fudan Univ, ENT Hosp, Eye Inst, Shanghai, Peoples R China
[2] Fudan Univ, Eye & ENT Hosp, Inst Med & Engn Innovat, Dept Ophthalmol, Shanghai, Peoples R China
[3] Chinese Acad Med Sci, Fudan Univ, NHC Key Lab Myopia, Key Lab Myopia, 19 Baoqing Rd, Shanghai 200031, Peoples R China
[4] Shanghai Res Ctr Ophthalmol & Optometry, Shanghai, Peoples R China
[5] Wenzhou Med Univ, Eye Hosp, Wenzhou, Zhejiang, Peoples R China
[6] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
[7] GB Bietti Fdn IRCCS, Rome, Italy
基金
中国国家自然科学基金;
关键词
SW-9000; MS-39; Agreement; Ocular biometric parameters; Optical biometry; CHAMBER DEPTH MEASUREMENTS; ORBSCAN IIZ; PENTACAM; THICKNESS; KERATOCONUS; PARAMETERS; IOLMASTER; DIAMETER;
D O I
10.1186/s40662-023-00330-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo assess agreement of measurements between a new optical low coherence reflectometry (OLCR) biometer (SW-9000, Suoer, Tianjin, China) and a spectral-domain optical coherence tomographer (SD-OCT)/Placido topographer (MS-39, CSO, Florence, Italy) in healthy subjects.MethodsA total of 66 right eyes from 66 healthy subjects were enrolled in this prospective study. Three consecutive measurements were randomly obtained with both devices by the same experienced operator to assess agreement. Bland-Altman plots and 95% limits of agreement (LoA) were used to verify the agreement between the devices. Results are presented as mean +/- standard deviation (SD).ResultsThe SD-OCT/Placido tomographer showed high agreement with the OLCR biometer for all parameters included in this study. The mean differences of central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AQD), mean keratometry (Km) and corneal diameter (CD) were 2.21 +/- 2.67 mu m (P < 0.001), - 0.10 +/- 0.03 mm (P < 0.001), - 0.10 +/- 0.04 mm (P < 0.001), - 0.01 +/- 0.22 D (P = 0.773) and 0.20 +/- 0.16 mm (P < 0.001), respectively. This implies that the inter-device difference in Km was not statistically significant, while the differences in CCT, ACD, AQD, CD were statistically but not clinically significant. The 95% LoAs of CCT, ACD, AQD, Km and CD were - 3.01 to 7.44 mu m, - 0.16 to - 0.05 mm, - 0.18 to - 0.03 mm, - 0.45 to 0.43 D, and - 0.12 to 0.51 mm, respectively.ConclusionsFor CCT, ACD, AQD, Km, and CD in healthy subjects, the new OLCR biometer has high agreement with the SD-OCT/Placido tomographer and can be used interchangeably due to the narrow range of 95% LoAs.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparison of Anterior Segment Measurements with Optical Low-coherence Reflectometry and Partial-coherence Interferometry Optical Biometers
    Can, Ertugrul
    Duran, Mustafa
    Cetinkaya, Tugba
    Ariturk, Nursen
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2016, 23 (04) : 288 - 292
  • [22] Comparison between a New Optical Biometry Device and an Anterior Segment Optical Coherence Tomographer for Measuring Central Corneal Thickness and Anterior Chamber Depth
    Huang, Jinhai
    Lu, Weicong
    Savini, Giacomo
    Chen, Hao
    Wang, Chengfang
    Yu, Xinxin
    Bao, Fangjun
    Wang, Qinmei
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [23] Accuracy and Repeatability of an Anterior Segment Swept-Source Optical Coherence Tomographer
    Peguda, Rajini
    Kang, Pauline
    Maseedupally, Vinod
    Swarbrick, Helen
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S300 - S306
  • [24] Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug cameras
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (04): : 471 - 478
  • [25] Comparison of two biometers: A swept-source optical coherence tomography and an optical low-coherence reflectometry biometer
    El Chehab, Hussam
    Agard, Emilie
    Dot, Corinne
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2019, 29 (05) : 547 - 554
  • [26] Repeatability and agreement of topometric parameters between a topographer, scheimpflug tomographer, and optical coherence tomographer in Keratoconus
    Angelo, Lize
    Gokul, Akilesh
    Wadhwa, Himanshu
    McGhee, Charles
    Ziaei, Mohammed
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 50 (08): : 904 - 905
  • [27] Comparison of anterior segment measurements obtained using a swept-source optical coherence tomography biometer and a Scheimpflug-Placido tomographer
    Lu, Weicong
    Li, Yue
    Savini, Giacomo
    Song, Benhao
    Hu, Qingjie
    Wang, Qinmei
    Bao, Fangjun
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (03): : 298 - 304
  • [28] Agreement of angle closure assessments between gonioscopy, anterior segment optical coherence tomography and spectral domain optical coherence tomography
    Tay, Elton Lik Tong
    Yong, Vernon Khet Yau
    Lim, Boon Ang
    Sia, Stelson
    Wong, Elizabeth Poh Ying
    Yip, Leonard Wei Leon
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (02) : 342 - 346
  • [29] Agreement of angle closure assessments between gonioscopy, anterior segment optical coherence tomography and spectral domain optical coherence tomography
    Elton Lik Tong Tay
    Vernon Khet Yau Yong
    Boon Ang Lim
    Stelson Sia
    Elizabeth Poh Ying Wong
    Leonard Wei Leon Yip
    International Journal of Ophthalmology, 2015, (02) : 342 - 346
  • [30] Comparing Agreement Between Optical Low-Coherence Reflectometry and Fourier-domain Optical Coherence Tomography during LASIK
    Lang, Paul
    Roozbahani, Mehdi
    Golan, Oren
    Randleman, James Bradley
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)