Nonenhanced Photon Counting CT of the Head Impact of the keV Level, Iterative Reconstruction and Calvaria on Image Quality in Monoenergetic Images

被引:4
|
作者
Michael, Arwed Elias [1 ,3 ]
Schoenbeck, Denise [1 ]
Woeltjen, Matthias Michael [1 ]
Boriesosdick, Jan [1 ]
Kroeger, Jan Robert [1 ]
Moenninghoff, Christoph [1 ]
Horstmeier, Sebastian [1 ]
Niehoff, Julius Henning [1 ]
Kabbasch, Christoph [2 ]
Goertz, Lukas [2 ]
Borggrefe, Jan [1 ]
机构
[1] Ruhr Univ Bochum, Johannes Wesling Univ Hosp, Dept Radiol Neuroradiol & Nucl Med, Bochum, Germany
[2] Univ Hosp Cologne, Dept Radiol & Neuroradiol, Cologne, Germany
[3] Johannes Wesling Univ Hosp Muehlenkreiskliniken Ao, Hans Nolte Str 1, D-32429 Minden, Germany
关键词
Computed tomography; Photon counting detector; Nonenhanced CT of the head; Virtual monoenergetic images; Iterative reconstruction; Quantum iterative reconstruction; DETECTOR CT; REDUCTION; ARTIFACTS;
D O I
10.1007/s00062-023-01331-w
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeNonenhanced computed tomography (CT) of the head is among the most commonly performed CT examinations. The spectral information acquired by photon counting CT (PCCT) allows generation of virtual monoenergetic images (VMI). At the same time, image noise can be reduced using quantum iterative reconstruction (QIR). In this study, the image quality of VMI was evaluated depending on the keV level and the QIR level. Furthermore, the influence of the cranial calvaria was investigated to determine the optimal reconstruction for clinical application.MethodsA total of 51 PCCT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) of the head were retrospectively analyzed. In a quantitative analysis, gray and white matter ROIs were evaluated in different brain areas at all available keV levels and QIR levels with respect to signal, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The distance to the cranial calvaria of the ROIs was included in the analysis. This was followed by a qualitative reading by five radiologists including experienced neuroradiologists.ResultsIn most ROIs, signal and noise varied significantly between keV levels (p < 0.0001). The CNR had a focal maximum at 66 keV and an absolute maximum at higher keV, slightly differently located depending on ROI and QIR level. With increasing QIR level, a significant reduction in noise was achieved (p < 0.0001) except just beneath the cranial calvaria. The cranial calvaria had a strong effect on the signal (p < 0.0001) but not on gray and white matter noise. In the qualitative reading, the 60 keV VMI was rated best.ConclusionIn nonenhanced PCCT of the head the selected keV level of the VMI and the QIR level have a crucial influence on image quality in VMI. The 60 keV and 66 keV VMI with high QIR level provided optimal subjective and objective image quality for clinical use. The cranial calvaria has a significant influence on the visualization of the adjacent brain matter; currently, this substantially limits the use of low keV VMIs (< 60 keV).
引用
收藏
页码:75 / 83
页数:9
相关论文
共 50 条
  • [31] The influence of iterative reconstruction level on image quality and radiation dose in CT pulmonary angiography examinations
    Harun, H. H.
    Karim, M. K. A.
    Abbas, Z.
    Sabarudin, A.
    Muniandy, S. C.
    Razak, H. R. A.
    Ng, K. H.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 178
  • [32] Photon-Counting Detector CT With Quantum Iterative Reconstruction Impact on Liver Lesion Detection and Radiation Dose Reduction
    Racine, Damien
    Mergen, Victor
    Viry, Anais
    Eberhard, Matthias
    Becce, Fabio
    Rotzinger, David C.
    Alkadhi, Hatem
    Euler, Andre
    INVESTIGATIVE RADIOLOGY, 2023, 58 (04) : 245 - 252
  • [33] Image quality of photon counting and energy integrating chest CT-Prospective head-to-head comparison on same patients
    Schwartz, Fides R.
    Ria, Francesco
    McCabe, Cindy
    Zarei, Mojtaba
    Rajagopal, Jayasai
    Molvin, Lior
    Marin, Daniele
    O'Sullivan-Murphy, Bryan
    Kalisz, Kevin R.
    Tailor, Tina D.
    Washington, Lacey
    Henry, Travis
    Samei, Ehsan
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 166
  • [34] Pediatric low-dose head CT: Image quality improvement using iterative model reconstruction
    Rabinowich, Aviad
    Shendler, Genady
    Ben-Sira, Liat
    Shiran, Shelly, I
    NEURORADIOLOGY JOURNAL, 2023, 36 (05): : 555 - 562
  • [35] Evaluation of thin-slice abdominal DECT using deep-learning image reconstruction in 74 keV virtual monoenergetic images: an image quality comparison
    Xu, Jack J. J.
    Loenn, Lars
    Budtz-Jorgensen, Esben
    Jawad, Samir
    Ulriksen, Peter S. S.
    Hansen, Kristoffer L. L.
    ABDOMINAL RADIOLOGY, 2023, 48 (04) : 1536 - 1544
  • [36] Evaluation of thin-slice abdominal DECT using deep-learning image reconstruction in 74 keV virtual monoenergetic images: an image quality comparison
    Jack J. Xu
    Lars Lönn
    Esben Budtz-Jørgensen
    Samir Jawad
    Peter S. Ulriksen
    Kristoffer L. Hansen
    Abdominal Radiology, 2023, 48 : 1536 - 1544
  • [37] Improving the quality of head and neck radiotherapy CT images using a second image reconstruction set
    Davis, Anne T.
    Nash, David
    Palmer, Antony L.
    Nisbet, Andrew
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 102 : 110 - 118
  • [38] Image quality improvement of a one-step spectral CT reconstruction on a prototype photon-counting scanner
    Rodesch, Pierre-Antoine
    Si-Mohamed, Salim A.
    Lesaint, Jerome
    Douek, Philippe C.
    Rit, Simon
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (01):
  • [39] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Layer, Yannik C.
    Mesropyan, Narine
    Kupczyk, Patrick A.
    Luetkens, Julian A.
    Isaak, Alexander
    Dell, Tatjana
    Attenberger, Ulrike I.
    Kuetting, Daniel
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [40] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Yannik C. Layer
    Narine Mesropyan
    Patrick A. Kupczyk
    Julian A. Luetkens
    Alexander Isaak
    Tatjana Dell
    Ulrike I. Attenberger
    Daniel Kuetting
    Scientific Reports, 13