Medial Locking Plate Can Increase the Fixation Stability of Vertical Femoral Neck Fracture in Young Adults?

被引:0
|
作者
Zanardi, Vinicius Vieira [1 ]
Guimaraes, Joao Antonio Matheus [2 ]
da Silveira Moller, Joao Victor [2 ]
de Mello Roesler, Carlos Rodrigo [1 ]
机构
[1] Univ Fed Santa Catarina, Univ Hosp, Biomech Engn Lab LEBm, Dept Mech Engn, Florianopolis, SC, Brazil
[2] Nat Inst Traumatol & Orthoped Jamil Haddad, Rio De Janeiro, RJ, Brazil
关键词
vertical shear femoral neck fractures; biomechanical testing; micromovements; BUTTRESS PLATE; SHEAR; AUGMENTATION;
D O I
10.1097/BTO.0000000000000623
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction:Vertical femoral neck fractures in young adults are usually caused by high-energy trauma. These injuries are difficult to stabilize due to significant shear forces acting on the fracture site. Their treatment is challenging and with high risks of complications, such as fixation failure, malunion, nonunion, and avascular necrosis of the femoral head. Material and Methods:It compared the biomechanical stability provided by 3 different fixation methods: (1) dynamic hip screw with derotation screw, (2) cannulated screws with a conventional medial bone plate, and (3) cannulated screws with a locked medial bone plate. These fixation structures were applied on fourth-generation medium-sized synthetic bones, with a 17 pound per cubic foot cellular foam core and cervico-diaphyseal angle of 120 degrees were used. The comparison was performed through biomechanical tests under cyclic loading followed by an ultimate load. The interfragmentary movement at the fracture site was the main variable for the cyclical phase. Results:The biomechanical comparison showed no statistical differences (P > 0.05) in stiffness, micromovement level, and mechanical resistance among the fixation techniques evaluated. Discussion:To stabilize the vertical femoral neck fracture in young patients, the use of a medial bone plate associated with cannulated screws on a "tie-rod" assembly is an option that supports the mechanical demand until the fracture healing. The locked medial plate did not provide an advantage compared with the conventional bone plate.
引用
收藏
页码:126 / 130
页数:5
相关论文
共 50 条
  • [21] Comparison of Three Fixation Methods for Femoral Neck Fracture in Young Adults: Experimental and Numerical Investigations
    Samsami, Shabnam
    Saberi, Sadegh
    Sadighi, Sanambar
    Rouhi, Gholamreza
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 35 (05) : 566 - 579
  • [22] Comparison of Three Fixation Methods for Femoral Neck Fracture in Young Adults: Experimental and Numerical Investigations
    Shabnam Samsami
    Sadegh Saberi
    Sanambar Sadighi
    Gholamreza Rouhi
    Journal of Medical and Biological Engineering, 2015, 35 : 566 - 579
  • [23] Failure Patterns of Femoral Neck Fracture Fixation in Young Patients
    Stockton, David J.
    Dua, Karan
    O'Brien, Peter J.
    Pollak, Andrew N.
    Hoshino, C. Max
    Slobogean, Gerard P.
    ORTHOPEDICS, 2019, 42 (04) : E376 - E380
  • [24] Stability of femoral neck fracture fixation: A finite element analysis
    Samsami, Shabnam
    Augat, Peter
    Rouhi, Gholamreza
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2019, 233 (09) : 892 - 900
  • [25] Femoral neck system versus cannulated screws for fixation of femoral neck fracture in young adults: a systematic review and meta-analysis
    Lu, Yao
    Huang, Zhilong
    Xu, Yibo
    Huang, Qiang
    Ren, Cheng
    Li, Ming
    Li, Zhong
    Sun, Liang
    Xue, Hanzhong
    Zhang, Kun
    Wang, Qian
    Ma, Teng
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2022, 14 (08): : 5480 - +
  • [26] SLIDING SCREW-PLATE FOR FIXATION OF FEMORAL-NECK FRACTURE
    NORDKILD, P
    SONNEHOLM, S
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06): : 616 - 619
  • [27] Biplane double supported screw fixation for femoral neck fracture in young adults: A prospective cohort study
    Sami, Abdus
    Prabhakar, Rahul
    Yadav, Ajay Kumar
    Jain, Vijay Kumar
    JOURNAL OF ORTHOPAEDICS, 2022, 33 : 117 - 123
  • [28] Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures
    Onder, Yilmaz
    Bulut, Tugrul
    Eroglu, Osman Nuri
    Ciklacandir, Samet
    Isler, Yalcin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (06)
  • [29] Medial Closing-Wedge Distal Femoral Osteotomy: Fixation With Proximal Tibial Locking Plate
    Passarelli Tirico, Luis Eduardo
    Demange, Marco Kawamura
    Bonadio, Marcelo Batista
    Helito, Camilo Partezani
    Gobbi, Riccardo Gomes
    Pecora, Jose Ricardo
    ARTHROSCOPY TECHNIQUES, 2015, 4 (06): : E687 - E695
  • [30] Successful fixation of supraglenoid tubercle fracture in a horse with a customised distal femoral locking plate
    Pallante, Marcello
    Coppo, Paola
    Destefanis, Chiara
    Delmedico, Nilli
    Bertuglia, Andrea
    VETERINARY RECORD CASE REPORTS, 2024, 12 (03):