Double-sided asymmetric method for automated fetal heart rate baseline calculation

被引:0
|
作者
Shapira, Rotem [1 ]
Kedar, Reuven [2 ,3 ]
Yaniv, Yael [1 ]
Keidar, Noam [1 ]
机构
[1] Technion IIT, Biomed Engn Fac, Lab Bioenerget & Bioelect Syst, Haifa, Israel
[2] Carmel Hosp, Dept Obstet & Gynecol, Haifa, Israel
[3] Technion Israel Inst Technol, Rappaport Fac Med, Haifa, Israel
关键词
Signal processing; Electronic fetal monitoring; Baseline; Fetal heart rate; Obstetric decision making; Gap interpolation; FIGO CONSENSUS GUIDELINES; LEAST-SQUARES; ALGORITHM; SIGNAL;
D O I
10.1007/s13246-023-01337-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The fetal heart rate (FHR) signal is used to assess the well-being of a fetus during labor. Manual interpretation of the FHR is subject to high inter- and intra-observer variability, leading to inconsistent clinical decision-making. The baseline of the FHR signal is crucial for its interpretation. An automated method for baseline determination may reduce interpretation variability. Based on this claim, we present the Auto-Regressed Double-Sided Improved Asymmetric Least Squares (ARDSIAsLS) method as a baseline calculation algorithm designed to imitate expert obstetrician baseline determination. As the FHR signal is prone to a high rate of missing data, a step of gap interpolation in a physiological manner was implemented in the algorithm. The baseline of the interpolated signal was determined using a weighted algorithm of two improved asymmetric least squares smoothing models and an improved symmetric least squares smoothing model. The algorithm was validated against a ground truth determined from annotations of six expert obstetricians. FHR baseline calculation performance of the ARDSIAsLS method yielded a mean absolute error of 2.54 bpm, a max absolute error of 5.22 bpm, and a root mean square error of 2.89 bpm. In a comparison between the algorithm and 11 previously published methods, the algorithm outperformed them all. Notably, the algorithm was non-inferior to expert annotations. Automating the baseline FHR determination process may help reduce practitioner discordance and aid decision-making in the delivery room.
引用
收藏
页码:1779 / 1790
页数:12
相关论文
共 50 条
  • [41] Mechanical behavior study of asymmetric deformation in double-sided symmetrical sequential shot peening process
    Chengyu Wang
    Weigang Li
    Jianjun Jiang
    Xin Chao
    Weikui Zeng
    Jie Yang
    [J]. The International Journal of Advanced Manufacturing Technology, 2021, 114 : 1189 - 1204
  • [42] Diurnal variations in baseline fetal heart rate, maternal heart rate and movement in a twin pregnancy
    Masami Muro
    Hideaki Shono
    Mayumi Shono
    Akira Uchiyama
    Tsuyoshi Iwasaka
    [J]. Sleep and Biological Rhythms, 2003, 1 (2) : 159 - 161
  • [43] Fetal heart rate baseline computation with a weighted median filter
    Boudet, Samuel
    de l'Aulnoit, Agathe Houze
    Demailly, Romain
    Peyrodie, Laurent
    Beuscart, Regis
    de l'Aulnoit, Denis Houze
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2019, 114
  • [44] A novel cardiotocography fetal heart rate baseline estimation algorithm
    Nidhal, Shahad
    Ali, M. A. Mohd.
    Najah, Hind
    [J]. SCIENTIFIC RESEARCH AND ESSAYS, 2010, 5 (24): : 4002 - 4010
  • [45] EFFECT OF SCOPOLAMINE ON FETAL HEART-RATE BASELINE VARIABILITY
    BOEHM, FH
    GROWDON, JH
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1974, 120 (08) : 1099 - 1104
  • [46] Robust Baseline Measurement for Reliable Fetal Heart Rate Evaluation
    Frigo, G.
    Giorgi, G.
    [J]. 2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 206 - 211
  • [47] Association of Fetal Heart Rate Baseline Change and Neonatal Outcomes
    Yang, Michael
    Stout, Molly J.
    Lopez, Julia D.
    Colvin, Ryan
    Macones, George A.
    Cahill, Alison G.
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 2017, 34 (09) : 879 - 886
  • [48] Can the reproducibility of fetal heart rate baseline estimation be improved?
    Ayres-de-Campos, D
    Bernardes, J
    Marsal, K
    Nickelsen, C
    Makarainen, L
    Banfield, P
    Xavier, P
    Campos, I
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2004, 112 (01) : 49 - 54
  • [49] BASELINE IN HUMAN-FETAL HEART-RATE RECORDS
    DAWES, GS
    HOUGHTON, CRS
    REDMAN, CWG
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1982, 89 (04): : 270 - 275
  • [50] Uniform generalized double-sided elimination method and the calculation of the fault current distribution for hybrid overhead-underground power lines
    Zou, Jun
    Yuan, Jian-Sheng
    Zhou, Yu-Kun
    Ma, Xin-Shan
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2002, 22 (10): : 112 - 115