Assessing lumbar vertebral bone quality: a methodological evaluation of CT and MRI as alternatives to traditional DEXA

被引:6
|
作者
Courtois, Emily C. [1 ]
Ohnmeiss, Donna D. [2 ]
Guyer, Richard D. [3 ]
机构
[1] Texas Back Inst, Plano, TX USA
[2] Texas Back Inst Res Fdn, 6020 W Parker Rd 200, Plano, TX 75093 USA
[3] Texas Back Inst, Ctr Disc Replacement, Plano, TX USA
关键词
Methodology; DEXA; CT; MRI; COMPUTED-TOMOGRAPHY; HOUNSFIELD UNITS; DENSITY; SCORES;
D O I
10.1007/s00586-023-07855-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeThe purpose of this study was to investigate the impact of various methods on the assessment of vertebral bone quality.MethodsA consecutive series of 427 candidates for lumbar disc replacement with lumbar DEXA and MRI and/or CT scans were included. Two measurement techniques were used on CTs-a sagittal and axial. From axial images, the upper, mid, and lower portions of each vertebral body were measured. Four MRI vertebral bone quality (VBQ) calculations were generated using separate equations.ResultsAll CT measures were highly correlated with each other, regardless of measurement or calculation method (range 0.925-0.995). Sagittal measurements were highly correlated with axial (r = 0.928, p < 0.001). CT values were correlated with DEXA (range 0.446-0.534). There was no benefit to measuring multiple axial images of each vertebral body vs. just midbody (r = 0.441 and 0.455, respectively).No MRI VBQ values were highly correlated with DEXA (r = - 0.103, p = 0.045). In receiver operating curve analysis, the area under the curve ranged from 0.539 to 0.558, indicating poor ability of VBQ to identify osteoporosis/osteopenia.ConclusionCT produced values more closely related to DEXA, while MRI was less reliable for osteoporosis/osteopenia screening. On CT, there was no benefit to making multiple measurements for each vertebral body to calculate a composite. Measuring sagittal CT images produced values similar to axial and required less time. While assessing bone quality from existing images rather than getting an additional DEXA scan is appealing, the methods of measuring these images needs standardization to maximize their utility.
引用
收藏
页码:3176 / 3182
页数:7
相关论文
共 50 条
  • [31] Would Roussouly classification affect the diagnostic efficiency of vertebral bone quality score for assessing osteopenia or osteoporosis in lumbar degenerative disease?
    Su, Tong
    Meng, Tong
    Zhao, Kangcheng
    Song, Dianwen
    Huang, Weibo
    Yin, Huabin
    EUROPEAN SPINE JOURNAL, 2025,
  • [32] Impact of contrast administration and CT reconstruction plane on Hounsfield units for assessing underlying bone quality in the lumbar spine
    Hamouda, Abdelrahman M.
    Pennington, Zach
    Potes, Maria Astudillo
    Shafi, Mahnoor
    Mikula, Anthony L.
    Lakomkin, Nikita
    Martini, Michael L.
    Bydon, Mohamad
    Kennel, Kurt A.
    Drake, Matthew T.
    Freedman, Brett A.
    Sebastian, Arjun S.
    Nassr, Ahmad
    Fogelson, Jeremy L.
    Elder, Benjamin D.
    JOURNAL OF NEUROSURGERY-SPINE, 2025, 42 (03) : 331 - 339
  • [33] Paravertebral injection of botulinum toxin-A reduces lumbar vertebral bone quality
    Wang, Xuepeng
    Wang, Shengjie
    Yan, Peng
    Bian, Zhenyu
    Li, Maoqiang
    Hou, Changju
    Tian, Jiwei
    Zhu, Liulong
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (10) : 2664 - 2670
  • [34] Vertebral Bone Quality Score and Postoperative Lumbar Lordosis Associated with Need for Reoperation After Lumbar Fusion
    Ehresman, Jeff
    Ahmed, A. Karim
    Lubelski, Daniel
    Schilling, Andrew
    Pennington, Zach
    Cottrill, Ethan
    McCracken, Julie
    Khan, Majid
    Witham, Timothy
    Sciubba, Daniel M.
    WORLD NEUROSURGERY, 2020, 140 : E247 - E252
  • [35] Characteristics of MRI‑based vertebral bone quality scores in elderly patients with vertebral fragility fractures
    Wenshuai Li
    Houze Zhu
    Junchuan Liu
    Hongsen Tian
    Jia Li
    Linfeng Wang
    European Spine Journal, 2023, 32 : 2588 - 2593
  • [36] Comparative Analysis of the 3 Cervical Vertebral Bone Quality (C-VBQ) Score Methodologies and Their Correlations to the Lumbar Vertebral Bone Quality (VBQ) Score
    Aguirre, Alexander O.
    Soliman, Mohamed A. R.
    Kuo, Cathleen C.
    Ruggiero, Nicco
    Im, Justin
    Khan, Asham
    Lim, Jaims
    Nyabuto, Elizabeth
    Smolar, David E.
    Mullin, Jeffrey P.
    Pollina, John
    WORLD NEUROSURGERY, 2024, 183 : E321 - E327
  • [37] Vertebral body bone mineral density in patients with lumbar spondylolysis: a quantitative CT study
    Gezer, Naciye Sinem
    Balci, Ali
    Kalemci, Orhan
    Koremezli, Nevin
    Akin, Isil Basara
    Ur, Koray
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2017, 23 (05) : 385 - 389
  • [38] Quantitative CT in the measurement of bone quantity and bone quality for assessing osteoporosis
    Dougherty, G
    MEDICAL ENGINEERING & PHYSICS, 1996, 18 (07) : 557 - 568
  • [39] Quantitative CT in the measurement of bone quantity and bone quality for assessing osteoporosis
    Dougherty, G.
    Medical Engineering and Physics, 1996, 18 (07): : 557 - 568
  • [40] Evaluation of Vertebral Bone Marrow with Diffusion Weighted MRI and ADC Measurements
    Turna, Onder
    Aybar, Mustafa Devran
    Tuzcu, Goksel
    Karagoz, Yesim
    Kesmezacar, Ozgu
    Turna, Isil Fazilet
    ISTANBUL MEDICAL JOURNAL, 2014, 15 (02): : 116 - 121