Cost-Effective Design Modification of a Sleeve Bearing with Large Bearing Clearance

被引:1
|
作者
Benti, Gudeta Berhanu [1 ]
Aidanpaeae, Jan-Olov [1 ]
Gustavsson, Rolf [2 ]
机构
[1] Lulea Univ Technol, Dept Engn Sci & Math, S-97187 Lulea, Sweden
[2] Vattenfall AB Res & Dev, S-81426 Alvkarleby, Sweden
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 03期
关键词
hydropower; four-lobe bearing; sleeve bearing; journal bearing; vertical rotors; rotordynamics; bearing coefficient; PERFORMANCE-CHARACTERISTICS; STABILITY;
D O I
10.3390/app14031214
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In 2015, a 45 MW vertical hydropower machine exhibited excessive vibration after refurbishment. Measurements revealed a substantial bearing clearance at the lower generator guide bearing. Consequently, the bearing was unable to generate sufficient opposing force to drive the rotor toward the bearing center, resulting in more pronounced overall system vibration. Addressing this challenge required a cost-effective and feasible solution for mitigating the vibration problem. To this end, a design modification was implemented wherein the lower generator guide bearing (originally a sleeve bearing) was modified to a four-lobe bearing by offsetting the two halves of the bearing twice in two axes. Numerical simulations and experimentations were conducted, and the dynamics of the machine before and after the design modification were investigated. Both the simulation and experimental results showed that the machine with the four-lobe bearing improved the system stability and reduced the vibration amplitudes. The numerical simulation result demonstrated that, due to the design modification, the first and second critical speeds were effectively eliminated for a speed range of up to three times the nominal speed. Furthermore, for nominal operation with unbalanced magnetic pull, the four-lobe bearing provided a stability advantage in terms of the modal parameters relative to the original sleeve bearing.
引用
下载
收藏
页数:17
相关论文
共 50 条
  • [31] Reactive Extrusion - cost-effective Process for the Modification of Lignins
    Feldner, Alexander
    Kiessler, Birgit
    WOCHENBLATT FUR PAPIERFABRIKATION, 2023, 151 (09):
  • [32] CONVENIENT AND COST-EFFECTIVE MODIFICATION OF NEUROMUSCULAR BLOCKADE MONITORS
    HARRISON, W
    BAULD, TJ
    TREMPER, KK
    JOURNAL OF CLINICAL MONITORING, 1994, 10 (01): : 72 - 73
  • [33] Innovative and cost-effective management of large omphalocele
    Gupta, Parthapratim
    JOURNAL OF PEDIATRIC SURGERY, 2007, 42 (06) : 1130 - 1132
  • [34] Reply to "Bleeding in Sleeve Gastrectomy-A Simple and Cost-Effective Solution"
    Mukherjee, Samrat
    Alhamdani, Ali
    Sufi, Pratik
    Parmar, Chetan
    OBESITY SURGERY, 2017, 27 (03) : 814 - 815
  • [35] Staple Line Bleeding in Sleeve Gastrectomy—a Simple and Cost-Effective Solution
    Saurav Chakravartty
    Diwakar R. Sarma
    Avril Chang
    Ameet G. Patel
    Obesity Surgery, 2016, 26 : 1422 - 1428
  • [36] Staple Line Bleeding in Sleeve Gastrectomy: a Simple and Cost-Effective Solution
    Kassir, Radwan
    Gugenheim, Jean
    Debs, Tarek
    Tiffet, Olivier
    Ben Amor, Imed
    Boutet, Claire
    OBESITY SURGERY, 2016, 26 (12) : 3021 - 3022
  • [37] Staple Line Bleeding in Sleeve Gastrectomy: a Simple and Cost-Effective Solution
    Radwan Kassir
    Jean Gugenheim
    Tarek Debs
    Olivier Tiffet
    Imed Ben Amor
    Claire Boutet
    Obesity Surgery, 2016, 26 : 3021 - 3022
  • [38] COST-EFFECTIVE DESIGN - A PRUDENT APPROACH TO THE DESIGN OF OPTICS
    PLUMMER, J
    LAGGER, W
    PHOTONICS SPECTRA, 1982, 16 (12) : 65 - 68
  • [39] Case Study of Cost-Effective Design Alternatives
    Reifschneider, Louis
    Linton, R. J.
    2011 ASEE ANNUAL CONFERENCE & EXPOSITION, 2011,
  • [40] COST-EFFECTIVE DESIGN OF RADIATION SHIELDING WINDOWS
    BOGAR, GF
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1983, 45 : 785 - 786