Impact of radiation dose reduction and iterative image reconstruction on CT-guided spine biopsies

被引:2
|
作者
Paprottka, Karolin J. [1 ]
Kupfer, Karina [1 ]
Schultz, Vivian [1 ]
Beer, Meinrad [3 ]
Zimmer, Claus [1 ,2 ]
Baum, Thomas [1 ]
Kirschke, Jan S. [1 ,2 ]
Sollmann, Nico [1 ,2 ,3 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Neuroradiol, Klinikum Rechts Isar, Munich, Germany
[2] Tech Univ Munich, TUM Neuroimaging Ctr, Klinikum Rechts Isar, Munich, Germany
[3] Univ Hosp Ulm, Dept Diagnost & Intervent Radiol, Ulm, Germany
关键词
SUSPECTED INFECTION; LESION BIOPSIES; TUBE CURRENT; PATIENT; FEASIBILITY; YIELD; MDCT;
D O I
10.1038/s41598-023-32102-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to systematically evaluate the impact of dose reduction on image quality and confidence for intervention planning and guidance regarding computed tomography (CT)-based intervertebral disc and vertebral body biopsies. We retrospectively analyzed 96 patients who underwent multi-detector CT (MDCT) acquired for the purpose of biopsies, which were either derived from scanning with standard dose (SD) or low dose (LD; using tube current reduction). The SD cases were matched to LD cases considering sex, age, level of biopsy, presence of spinal instrumentation, and body diameter. All images for planning (reconstruction: "IMR1") and periprocedural guidance (reconstruction: "iDose4") were evaluated by two readers (R1 and R2) using Likert scales. Image noise was measured using attenuation values of paraspinal muscle tissue. The dose length product (DLP) was statistically significantly lower for LD scans regarding the planning scans (SD: 13.8 +/- 8.2 mGy*cm, LD: 8.1 +/- 4.4 mGy*cm, p < 0.01) and the interventional guidance scans (SD: 43.0 +/- 48.8 mGy*cm, LD: 18.4 +/- 7.3 mGy*cm, p < 0.01). Image quality, contrast, determination of the target structure, and confidence for planning or intervention guidance were rated good to perfect for SD and LD scans, showing no statistically significant differences between SD and LD scans (p > 0.05). Image noise was similar between SD and LD scans performed for planning of the interventional procedures (SD: 14.62 +/- 2.83 HU vs. LD: 15.45 +/- 3.22 HU, p = 0.24). Use of a LD protocol for MDCT-guided biopsies along the spine is a practical alternative, maintaining overall image quality and confidence. Increasing availability of model-based iterative reconstruction in clinical routine may facilitate further radiation dose reductions.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] PET/CT-guided Interventions: Personnel Radiation Dose
    Ryan, E. Ronan
    Thornton, Raymond
    Sofocleous, Constantinos T.
    Erinjeri, Joseph P.
    Hsu, Meier
    Quinn, Brian
    Dauer, Lawrence T.
    Solomon, Stephen B.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 36 (04) : 1063 - 1067
  • [42] Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
    Niesten, Joris M.
    van der Schaaf, Irene C.
    Riordan, Alan J.
    de Jong, Hugo W. A. M.
    Horsch, Alexander D.
    Eijspaart, Daniel
    Smit, Ewoud J.
    Mali, Willem P. T. M.
    Velthuis, Birgitta K.
    EUROPEAN RADIOLOGY, 2014, 24 (02) : 484 - 493
  • [43] Radiation Dose Reduction in Paranasal Sinus CT: With Feasibility of Iterative Reconstruction Technique
    Bang, Minseo
    Choi, Seong Hoon
    Park, Jongha
    Kang, Byeong Seong
    Kwon, Woon Jung
    Lee, Tae Hoon
    Nam, Jung Gwon
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2016, 155 (06) : 982 - 987
  • [44] Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
    Joris M. Niesten
    Irene C. van der Schaaf
    Alan J. Riordan
    Hugo W. A. M. de Jong
    Alexander D. Horsch
    Daniel Eijspaart
    Ewoud J. Smit
    Willem P. T. M. Mali
    Birgitta K. Velthuis
    European Radiology, 2014, 24 : 484 - 493
  • [45] Possibilities of dose reduction during CT imaging by application of iterative image reconstruction
    Bajzik Gabor
    Toth Anetti
    Donko Tamas
    Kovacs Peter
    Sipos David
    Pandur Attila Andras
    Moizs Mariann
    Hadjiev Janaki
    Repa Imre
    Kovacs Arpad
    ORVOSI HETILAP, 2019, 160 (35) : 1387 - 1394
  • [46] Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique
    Kim, Jun-Hwee
    Kim, Myung-Joon
    Kim, Ha Yan
    Lee, Mi-Jung
    CLINICAL IMAGING, 2014, 38 (05) : 710 - 714
  • [47] Ultra-low-dose Protocol for CT-guided Lung Biopsies
    Smith, Jason C.
    Jin, Daniel H.
    Watkins, Greg E.
    Miller, Theodore R.
    Karst, Jeffrey G.
    Oyoyo, Udo E.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (04) : 431 - 436
  • [48] Radiation Dose Reduction in Computed Tomography: Implementation of an Iterative Image Reconstruction Method
    Chartrand-Lefebvre, Carl
    Prosmanne, Odile
    Belair, Manon
    Therasse, Eric
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (04): : 386 - 386
  • [49] Efficacy of CT-guided biopsies of the spine in patients with spondylitis - an analysis of 164 procedures
    Heyer, Christoph M.
    Brus, Lisa-Johanna
    Peters, Soeren A.
    Lemburg, Stefan P.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) : E244 - E249
  • [50] Patient-specific image denoising for ultra-low-dose CT-guided lung biopsies
    Michael Green
    Edith M. Marom
    Eli Konen
    Nahum Kiryati
    Arnaldo Mayer
    International Journal of Computer Assisted Radiology and Surgery, 2017, 12 : 2145 - 2155