Gas chromatography coupled to time-of-flight mass spectrometry using parallel electron and chemical ionization with permeation tube facilitated reagent ion control for material emission analysis

被引:5
|
作者
Braekling, Steffen [1 ,2 ]
Hinterleitner, Christina [3 ]
Cappellin, Luca [1 ,4 ]
Vetter, Marleen [1 ]
Mayer, Ingo [3 ]
Benter, Thorsten [2 ]
Klee, Sonja [1 ]
Kersten, Hendrik [2 ]
机构
[1] TOFWERK, Thun, Switzerland
[2] Univ Wuppertal, Dept Phys & Theoret Chem, Wuppertal, Germany
[3] Bern Univ Appl Sci, Architecture Wood & Civil Engn, Biel, Switzerland
[4] Univ Padua, Dept Chem Sci, Padua, Italy
基金
欧盟地平线“2020”;
关键词
VOLATILE ORGANIC-COMPOUNDS; VOC EMISSIONS; AIR-POLLUTION; PROTONATION; MS;
D O I
10.1002/rcm.9461
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleVolatile organic compounds (VOCs) emitted by an artificial leather part for car interiors are determined using GC-MS (gas chromatograph coupled to a mass spectrometer) using simultaneous electron and chemical ionization (EI&CI). A device for swift reagent ion switching in CI mode between consecutive runs is presented. MethodsVOCs emitted from the investigated material were sampled onto Tenax (R) absorption tubes using micro emission chambers and subsequently injected into the GC through thermal desorption. The detector was a time-of-flight mass spectrometer (TOFMS) simultaneously operating in EI and CI modes during a single chromatographic run. A custom permeation tube setup allowed for swift selection between various reagent ions in CI mode, e.g., [N2H](+), [H3O](+), [(H2O)(2)H](+), and [NH4](+). ResultsDifferent reagent ions are swiftly selectable between single GC runs without hardware changes. Differences in precursor ion survival yields and the selectivity of the various reactants were carefully assessed. Several examples for the improved identification of unknown compounds with the available complementary and comprehensive EI&CI data set are demonstrated for a relevant material emission application. ConclusionThe presented technique provides additional value to the standard GC-EI/MS procedure commonly used for material emission characterization. It allows for a non-targeted analysis approach with moderate analysis time.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Ionization of pesticides using a far-ultraviolet femtosecond laser in gas chromatography/time-of-flight mass spectrometry
    Hashiguchi, Yuichi
    Zaitsu, Shin-ichi
    Imasaka, Totaro
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (22) : 7053 - 7059
  • [32] Ionization of pesticides using a far-ultraviolet femtosecond laser in gas chromatography/time-of-flight mass spectrometry
    Yuichi Hashiguchi
    Shin-ichi Zaitsu
    Totaro Imasaka
    Analytical and Bioanalytical Chemistry, 2013, 405 : 7053 - 7059
  • [33] Qualitative nontarget analysis of landfill leachate using gas chromatography time-of-flight mass spectrometry
    Jernberg, Joonas
    Pellinen, Jukka
    Rantalainen, Anna-Lea
    TALANTA, 2013, 103 : 384 - 391
  • [34] Metabolite profiling of hemodialysate using gas chromatography time-of-flight mass spectrometry
    Qi, Xin
    Zhang, Yinan
    Gao, Jiayuan
    Chen, Tianlu
    Zhao, Aihua
    Yan, Yucheng
    Jia, Wei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (05) : 1142 - 1147
  • [35] Gas chromatography/time-of-flight mass spectrometry of triacetone triperoxide based on femtosecond laser ionization
    Yamaguchi, Satoshi
    Uchimura, Tomohiro
    Imasaka, Tomoko
    Imasaka, Totaro
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (19) : 3101 - 3106
  • [36] Application of Hadamard transform to gas chromatography/nonresonant multiphoton ionization/time-of-flight mass spectrometry
    Cheng, Chao-Chiang
    Chang, Hung-Wei
    Uchimura, Tomohiro
    Imasaka, Totaro
    Kaneta, Takashi
    Lin, Cheng-Huang
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (4-5) : 626 - 630
  • [37] Chemical profiling of Dioscorea septemloba by High Performance Liquid Chromatography Coupled to Electrospray Ionization and Quadrupole Time-of-Flight Mass Spectrometry
    Ling, Yun
    Chen, Lu
    Wang, Dan
    Xiao, Xin
    Xu, Wenjing
    Yan, Hui
    Yu, Hongling
    Zhang, Qing
    Qu, Weihong
    Chen, Jian
    Ji, Xiaohong
    Yu, Qunying
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2020, 58 (08) : 709 - 717
  • [38] Superimposition of a magnetic field around an ion guide for electron ionization time-of-flight mass spectrometry
    Yue, BF
    Lee, ED
    Rockwood, AL
    Lee, ML
    ANALYTICAL CHEMISTRY, 2005, 77 (13) : 4167 - 4175
  • [39] Analysis of benzofuran derivatives using electrospray ionization ion trap and electrospray ionization quadrupole time-of-flight mass spectrometry
    Wu, Zhi-Jun
    Han, Dan
    Chen, Xiao-Zhen
    Fang, Dong-Mei
    Qi, Hua-Yi
    Zhang, Guo-Lin
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (08) : 1211 - 1215
  • [40] Analysis of special surfactants by comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry
    Wulf, Volker
    Wienand, Nils
    Wirtz, Michaela
    Kling, Hans-Willi
    Gaeb, Siegmar
    Schmitz, Oliver J.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (05) : 749 - 754